The effect of condensate inundation on steam condensation heat transfer in a tube bundle

Abstract

dc:description.abstract

Steam-condensation heat-transfer measurements were made using a 5-tube in-line test condenser with an additional perforated tube to simulate up to 30 active tubes. Results were obtained for smooth tubes, wire-wrapped tubes and dropwise-coated tubes. The average outside heat-transfer coefficient for 30 smooth tubes was 0.64 times the Nusselt coefficient for the first tube. A total of eight wirediameter and wire-pitch combinations were tested: 1.6-mmdiameter wire wrapped at 16 mm, 7.6 mm and 4 mm wire pitches, 1 . 0-mm-diameter wire wrapped at 8 mm, 4 mm and 2 mm wire pitches, and . 5-mm-diameter wire wrapped at 4 mm and 2 mm wire pitches. The best bundle performance was obtained when the tubes were wrapped with 1 .0-mm-diameter wire at a wire pitch of 4 mm. This combination resulted in an average outside heat-transfer coefficient for 30 tubes that was 1.15 times the value computed for the first tube using the Nusselt theory. The average outside heat-transfer coefficient for the 30 dropwise-coated tubes was 1.1 times the value of the heat- transfer coefficient for the first tube in the tube bundle. Utilizing either wire-wrapped tubes or dropwisecoated tubes, it is possible to significantly reduce the condenser surface area and overall size.

Degree

thesis:*
Name thesis:degree_name
M.S. in Mechanical Engineering
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
College dc:contributor.school
Naval Postgraduate School
Grantor
Naval Postgraduate School
Year dc:date.issued
1985

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Brower, Steven K.
Advisors dc:contributor.advisor
  • Marto, P.J.
  • Wanniarachchi, A.S.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Approved for public release; distribution is unlimited.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10945/21291

Chain of custody

source
Harvested from
Naval Postgraduate School
Base URL
calhoun.nps.edu/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Brower, Steven K.. The effect of condensate inundation on steam condensation heat transfer in a tube bundle. Masters thesis, Naval Postgraduate School, 1985. https://hdl.handle.net/10945/21291