Experimental development of tubseide heat transfer correlations for laminar flow with and without inserts.
Abstract
dc:description.abstractAn experimental study of laminar flow heat transfer of an ethylene glycol/water mixture in an electrically heated horizontal tube using wire mesh (HEATEX) and twisted tape inserts was investigated. Twelve thermocouples, inserted in the tube wall at four longitudinal locations, enabled a mean inside experimental heat-transfer coefficient to be accurately measured. A constant wall heat flux boundary condition was placed on the wall by wrapping six 200 W flexible heater tapes tightly around the tube. The ethylene glycol/water mixture provided a coolant Reynolds number between 200-5000 and a Prandtl number between 30-140. Two smooth inside diameters and a roped tube profile were tested with and without the inserts. Heattransfer correlations for tubes without inserts were developed and compared with theory for both thermally and hydrodynamically developing flow. Correlations were also developed for the two types of inserts.
Degree
thesis:*- Name thesis:degree_name
- M.S. in Mechanical Engineering
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Department dc:contributor.department
- Mechanical Engineering
- College dc:contributor.school
- Naval Postgraduate School
- Grantor dc:publisher
- Monterey, California. Naval Postgraduate School
- Year dc:date.issued
- 1992
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Guido, Joseph D.
- Advisors dc:contributor.advisor
-
- Marto, P.J.
- Memory, Stephen B.
Rights
dc:rights- Statement dc:rights
-
- Approved for public release; distribution is unlimited.
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10945/23668