Back to search

Monterey, CA; Naval Postgraduate School

Cost benefit analysis: closed-cell polyurethane foam use in DoD forward-deployed structures, and as an alternative building material, to reduce operational fuel demand and associated costs

Abstract

dc:description.abstract

The purpose of this project is to identify the costs and benefits associated with the application of closed-cell spray foam insulation to forward-deployed, semipermanent/nonpermanent structures, and to provide recommendations regarding future integration, use, and employment. According to the Department of Defense (DOD), forward-deployed generators, used to provide power to base support activities, are the largest single consumer of fuel throughout the battlefield. Eighty percent of the energy provided by generators is assessed to power environmental control units that run incessantly due to the poor insulating properties of the structures, according to a 2010 study conducted by the Department of the Air Force Civil Engineer Support Agency. Recent DOD policy has focused more on energy use and consumption but fails to address, and provide solutions for, major consumers of fuel throughout the battlefield. The incorporation of closed-cell, spray foam insulation into legacy DOD forward-deployed construction practices yields a significant return on investment, short-payback/break-even period, and reduces mission and personnel risk to deployed military forces.

Degree

thesis:*
Name thesis:degree_name
Master of Business Administration
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Business Administration
Grantor dc:publisher
Monterey, CA; Naval Postgraduate School
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Marsh, Robert J.
  • Caballero, Steven L.
  • Gerry, Stephen D.
Advisors dc:contributor.advisor
  • Arkes, Jeremy
  • Landry, Steven

Rights

dc:rights
Statement dc:rights
  • This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
  • Approved for public release; distribution is unlimited.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10945/45895

Chain of custody

source
Harvested from
Naval Postgraduate School
Base URL
calhoun.nps.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Marsh, Robert J.; Caballero, Steven L.; Gerry, Stephen D.. Cost benefit analysis: closed-cell polyurethane foam use in DoD forward-deployed structures, and as an alternative building material, to reduce operational fuel demand and associated costs. Masters thesis, Monterey, CA; Naval Postgraduate School, 2015. https://hdl.handle.net/10945/45895