Back to search

Monterey, CA; Naval Postgraduate School

THE IMPACT OF TECHNOLOGIES AND MISSIONS ON CONTINGENCY BASE FUEL CONSUMPTION

Abstract

dc:description.abstract

Fossil fuels satisfy the bulk of the U.S. military's energy requirements for transportation and sustainment needs. In recent years, deployments to Operation Enduring Freedom (OEF), Operation Iraqi Freedom (OIF), and Operation Inherent Resolve (OIR) have highlighted inefficiencies in how the U.S. military generates electrical power. Many strategies have been proposed to unleash the U.S. military from the tether of fuel. This paper presents a mixed integer linear program to minimize the fuel needed to meet power requirements at a contingency base over a 24-hour period. The paper then assesses the impact on fuel consumption and generator run-hours of introducing energy storage systems and photovoltaic arrays to different power demand scenarios based on the mission, geographic, and seasonal parameters. Removing the traditional requirement for spinning reserves and allowing generators to operate at 100% of their rated load resulted in substantial reductions in generator run-hours across all scenarios. The results showed that adding an energy storage system had effectively no impact on generator run-hours or fuel consumption, and that the impact of adding a photovoltaic array was highly dependent upon the latitude and season in which the contingency base was established. The author concludes that diesel and JP-8 are the best methods for storing energy at a contingency base, and that reducing energy demand is the most direct way to reduce fuel consumption and generator run-hours.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Applied Mathematics
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Applied Mathematics
Department dc:contributor.department
Applied Mathematics (MA)
Grantor dc:publisher
Monterey, CA; Naval Postgraduate School
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kiser, Erik
Advisor dc:contributor.advisor
  • Krener, Arthur J.
Committee member dc:contributor.committeemember
  • Zhou, Hong

Rights

dc:rights
Statement dc:rights
  • This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
  • Approved for public release; distribution is unlimited.

Identifiers

dc:identifier.*
Thesis Thesis Identifier
30532

Chain of custody

source
Harvested from
Naval Postgraduate School
Base URL
calhoun.nps.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Kiser, Erik. THE IMPACT OF TECHNOLOGIES AND MISSIONS ON CONTINGENCY BASE FUEL CONSUMPTION. Masters thesis, Monterey, CA; Naval Postgraduate School, 2018. https://hdl.handle.net/10945/59699