Back to search
Monterey, California. Naval Postgraduate School
Radiation dose analysis of NPS flash X-ray facility using silicon PIN diode
Abstract
dc:description.abstractRadiation output of the NPS Flash X-ray facility has been analyzed using commercial silicon PIN diodes. These results have been compared to dosimetry techniques using CaF2 TLDs (thermoluminescent dosimeters). The silicon PIN diodes were irradiated with photon energies of approximately 1 MeV and dose rates up to 1010 rad(Si)/s. These techniques and results can be used to provide real time calibration of the Flash X-ray facility.
Degree
thesis:*- Name thesis:degree_name
- M.S. in Electrical Engineering
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Electrical Engineering
- Department dc:contributor.department
- Electrical and Computer Engineering
- Grantor dc:publisher
- Monterey, California. Naval Postgraduate School
- Year dc:date.issued
- 2003
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Jones, Bernard L.
- Advisor dc:contributor.advisor
-
- Weatherford, Todd R.
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
- Approved for public release; distribution is unlimited.
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10945/6303