Back to search

University of Akron

The effect of differentiation technique utilized in continuous noninvasive blood pressure measurement

Abstract

dc:description

The measurement of blood pressure is a vital tool for any healthcare provider, purveying information that could help diagnose any number of pathologies. This is especially the case in critical care settings where the ability to continuously measure arterial blood pressure impacts immediate medical decisions. Of the techniques for noninvasive blood pressure measurement, cuff auscultation is clinically most often utilized. Unfortunately, this method requires a minimum rest period of one minute. Since this time lapse is unacceptable in a critical care setting, the need arises for a continuous and noninvasive method for blood pressure measurement. Several such commercially available methods exist, but they are often limited in clinical usefulness. It was the purpose of this study to investigate one such method involving the calculation of pulse transit time. This research was focused on: using both artificial simulations and previously measured simultaneous physiological electrocardiograph (ECG), photoplethysmograph (PPG), and continuous tonometric blood pressure data; applying the algorithm described by Fung to calculate arterial blood pressures from pulse transit time, and investigating an improvement to this algorithm; applying several digital differentiation techniques (spectral, central difference, original Pan-Tompkins, and Pan-Tompkins errata differentiation) for both ECG R-spike detection (compared to ECG R-spike detection without differentiation) and PPG landmark detection; and determining if statistically significant differences existed between the mean arterial pressures (MAP) obtained by various methodologies applied to several PPG curves, and between the beat-to-beat blood pressure measurements made by tonometry. Additionally this research investigated both mathematical and statistical differences that existed when each of the digital differentiators were applied to Fourier reconstructed idealized ECG and PPG waveforms. The primary conclusions drawn from this testing were that although the calculated values were not identical, statistically significant differences did not exist: between the respective digital differentiators, between the PTTs and between the MAPs determined from each testing iteration, and between the Fung algorithm and a modification made thereto. There was a statistically significant difference between those MAPs calculated through derivative-based ECG R-spike detection and direct R-spike detection; with the mean of the MAPs determined without derivative-based ECG R-spike detection performing more favorably compared its derivative alternative.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Engineering
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
University of Akron
Year dc:date
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mueller, Jonathon W.
Contributors dc:contributor
  • Mugler, Dale
  • Taylor, Bruce

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Mueller, Jonathon W.. The effect of differentiation technique utilized in continuous noninvasive blood pressure measurement. masters thesis, University of Akron, 2006. http://rave.ohiolink.edu/etdc/view?acc_num=akron1145295553