Back to search

University of Akron

HIGH-FREQUENCY IMPEDANCE CHARACTERISTICS AND HEALTH CONDITION MONITORING OF OVERHEAD POWER LINES

Abstract

dc:description

In an age where functioning businesses are almost inconceivable in the absence of electric power, power interruption that can even last for a short period of time can cause tremendous losses of productivity, material, and revenue. Hence, electric power systems should be highly reliable. For reliable operation of power systems, continuous power line health monitoring should be conducted. By continuously monitoring the power lines, critical damages can be detected in their early stage of development. This allows appropriate measures to be applied on time; thereby improving the reliability of the power system while significantly reducing its maintenance costs.Overhead transmission lines are an intricate part of the power system, and their health condition is very important for reliable operation of the overall system. In this thesis, an approach to health monitoring of electric power lines using high frequency impedance characteristics is presented. This technique can detect faults in the power lines, and monitor their health condition. In order to identify damaged and faulty power lines, high-frequency impedance analysis is performed by observing the effects of damages and faults on the line impedance. A threshold value is set to determine if the power line needs replacement due to excessive damage. The proposed technique is verified through MatlabTM simulations and experimental tests. Here, three 28-foot long conductors are considered.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Engineering
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Electrical Engineering
Grantor dc:publisher
University of Akron
Year dc:date
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Habtemariam, Filmon A.
Contributors dc:contributor
  • De Abreu Garcia, J. Alexis

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Habtemariam, Filmon A.. HIGH-FREQUENCY IMPEDANCE CHARACTERISTICS AND HEALTH CONDITION MONITORING OF OVERHEAD POWER LINES. masters thesis, University of Akron, 2016. http://rave.ohiolink.edu/etdc/view?acc_num=akron1472735633