MRI susceptometry: Theory and robustness of an external phantom method for measuring bulk susceptibility from MRI field echo phase reconstruction maps applied to human liver iron overload
Abstract
dc:descriptionA novel method for estimating the susceptibility of an object using the MRI field distortions in an external reference water bath next to the object is described. The field measurement is obtained using a MRI phase reconstruction from a Gradient Echo scan. A field model of an arbitrary object in a static magnetic field is discretely calculated using a Fourier convolution method from geometry determined from the magnitude reconstruction. Least squares estimation then yields the susceptibility of the object. Required (and proven) assumptions include; superposition, object homogeneity, negligible higher order field terms, field model accuracy, geometrical model accuracy and correlation of MRI FE phase to field distortion. MRI susceptometry estimation of in vitro phantoms yielded susceptibility estimates which correlated well with known values (r > 0.9975). This external reference bath MRI susceptometry method could be used to quantitate iron levels in iron overload patients. The errors which may occur in MRI susceptometry include field noise, and model errors including; outline error, outline shift, compartment inhomogeneity, volume error and unmodeled sources of field distort ion. Ultimately, the model errors can all be treated as unmodeled sources. Simulations and in vitro studies indicate that expected levels of field noise will not reduce the efficacy of the susceptibility estimations. However, unmodeled sources with relative strengths on the order of an unmodeled lung to a modeled liver of normal iron levels will reduce the efficacy of the fit (for a 22 patient in vivo experiment, r < 0.6). Filter application will alter the noise model, and improve the fit. Additionally, choosing the data set which lies closest to the organ of interest (i.e. the liver) will also improve the fit. With filtering and data set restriction, the estimates of the in vivo patient data were improved (r > 0.85). However, correlation of only the normal and low-level iron overload patients was not improved (r < 0.5).
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 1993
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Holt, Randall William
- Contributors dc:contributor
-
- Diaz, Pedro
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case1057155289