Tests were conducted under a concentrated static, stationary pulsating and moving constant wheel-load on 1/3-scale (P-Series) and 1/6.6-scale (B-Series) physical models of concrete bridge decks of a simply supported non-composite 50-ft long bridge with an 8.5-in. thick concrete deck supported on four steel girders spaced at 7 and 10 ft. Three deck designs are studied: (a) AASHTO "orthotropic" steel reinforcement, (b) Ontario "isotropic" steel reinforcement, and (c) "isotropic" minimum steel reinforcement. The presence of membrane compressive forces (arching action) in the deck enhances its static ultimate strength. Static ultimate strength values for the decks, P u, up to about three times the Johansen load are measured. The predicted critical deflections at instability of a 2-D 3-hinge compressive strut model (snap-through mechanism) restrained at the pinned supports by a horizontal elastic spring, and subjected at the crown to a concentrated vertical load correlate well with the measured ultimate deck deflections. The type of applied fatigue loading has a profound influence on the fatigue behavior of the decks. Under a moving constant wheel-load, the initial two-way deck slab action changes to a one-way slab action as failure is approached. The bridge decks subjected to a stationary pulsating load exhibited a flexural radial cracking, while those under a moving constant wheel-load exhibited a flexural grid-like pattern similar to the grid of the bottom steel layer. For a given applied fatigue load level, the decks subjected to a stationary pulsating loading regime exhibited higher fatigue life than those subjected to a moving load. Based on an exponential curve fit of the fatigue data in this study (log P/P u vs. logN cf or logN pf), while the 2.5 × 10<sup>6</sup> load cycle fatigue strength of the deck models under a stationary pulsating load ranges between 0.47 and 0.54 P u (safety factor 5 ÷ 12), at 2.5 × 10<sup>6</sup> wheel-load passages under a moving wheel-load is estimated to be at 0.21 to 0.28 P u (safety factor 2 ÷ 4). The fatigue strength of the bridge decks under a moving constant wheel-load is in the same range as the cracking load level while the fatigue strength under a stationary pulsating load is similar to the yielding load level for the steel reinforcement. (Abstract shortened by UMI.)

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Civil Engineering
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
1993

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Petrou, Michael Frixos
Contributors dc:contributor
  • Perdikaris, Philip

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Petrou, Michael Frixos. Fatigue performance of AASHTO and Ontario design for non-composite reinforced concrete bridge decks. doctoral thesis, Case Western Reserve University School of Graduate Studies, 1993. http://rave.ohiolink.edu/etdc/view?acc_num=case1060797619