Back to search

Case Western Reserve University School of Graduate Studies

Motion control of neuromuscular skeletal systems using a multiple contact nerve cuff electrode

Abstract

dc:description

A flat interface nerve electrode (FINE) is a type of nerve cuff electrode designed to increase spatial selectivity by reshaping a nerve and realigning fascicles inside the nerve trunk. FINE has shown improved fascicular and subfascicular selectivity enabling the activation of many muscles with a single electrode. Despite significant improvement in the spatial selectivity of FINE, a motion control algorithm for Functional Electrical Stimulation (FES) using a FINE has not yet been developed, due to the inherent complexities in neuromuscular skeletal systems and the nerve-electrode interface. In this study, a novel motion control algorithm is presented to overcome these difficulties. The proposed control method does not require an analytical model of the system being controlled. Therefore, this control method is suitable for FES control with a FINE, because finding an accurate model with FINE is extremely difficult. In order to test the performance of the control algorithm, a computational model of the human ankle joint system was developed along with a finite element model of the sciatic nerve. The results indicate that both the ankle and subtalar joint motion could be controlled using a twenty-contact FINE on the sciatic nerve. The proposed controller was also tested in an acute rabbit experimental study, and the result showed good reference trajectory tracking performance within 10% average RMS error. The results in both computational simulation study and animal experiment study show that this novel control method is suitable for the system where a model is not available and where the feedback signals are difficult to obtain.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Park, Hyun-Joo
Contributors dc:contributor
  • Durand, Dominique

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Park, Hyun-Joo. Motion control of neuromuscular skeletal systems using a multiple contact nerve cuff electrode. doctoral thesis, Case Western Reserve University School of Graduate Studies, 2011. http://rave.ohiolink.edu/etdc/view?acc_num=case1309506374