Using a model-based approach, we designed and evaluated nonlinear combined feedforward-feedback algorithms to control arm movements in the presence of a wide range of perturbations: (1) manipulation of objects of unknown mass, (2) sensor noise, (3) muscle fatigue, (4) model uncertainty with respect to the true inertial properties of the arm and the true muscle dynamics, and (5) input time delays. These algorithms were developed specifically for use in FES neuroprostheses for individuals with paralysis due to spinal cord injury and other neurological disorders. An initial comparison of combined feedforward-feedback proportional-derivative (PD), adaptive control, and sliding mode control showed that input time delays quickly caused instability for all three controllers if feedback gains were chosen too high. Decreasing the feedback gains (i.e., shifting towards feedforward control) re-established stability, but greatly reduced performance as measured by the root-mean-square error between the specified movement intent and the simulated joint angles. Input time delays are unavoidable in FES applications, arising from the muscle dynamics and the relatively low stimulation frequency (i.e. 12Hz) typically used in upper extremity FES neuroprostheses. The destabilizing effects of time delay therefore cannot be ignored. Using a 2DOF musculoskeletal arm model, we designed and evaluated a nonlinear combined feedforward-feedback controller with time delay compensation. In the presence of a typical 80ms time delay, this controller achieved excellent tracking accuracy, both under ideal conditions (shoulder RMSE: 0.27º, elbow RMSE: 0.62º) and in the presence of a wide variety of perturbations expected under normal operating conditions (shoulder RMSE: 2.99º, elbow RMSE: 5.15º). We extended this time delay compensating controller to a more functionally relevant 5DOF arm model. This extended controller achieved stable, accurate tracking, even in the presence of time delay, measurement noise, muscle fatigue and additional loading - but only if the inertial properties of the arm were exactly known. Future research in gravity compensation and adaptation may further improve the robustness of the time delay compensating controller for the 5DOF arm model. This work represents an important step towards a clinically viable controller for upper extremity FES neuroprostheses for human SCI subjects.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Cooman, Peter
Contributors dc:contributor
  • Kirsch, Robert

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Cooman, Peter. Nonlinear Feedforward-Feedback Control of an Uncertain, Time-delayed Musculoskeletal Arm Model for use in Functional Electrical Stimulation. doctoral thesis, Case Western Reserve University School of Graduate Studies, 2014. http://rave.ohiolink.edu/etdc/view?acc_num=case1386229121