Back to search

Case Western Reserve University School of Graduate Studies

LUX Thermosyphon Cryogenics and Radon-Related Backgrounds for the First WIMP Result

Abstract

dc:description

The cold, non-baryonic dark matter hypothesis describes the motions of galaxies and clusters, as well as the character of the large scale structure of the universe. Particle freeze- out arguments suggest a weakly interacting massive particle (WIMP) plays the dark matter role. Decades of experiments have sought direct interaction with normal matter and this thesis describes the efforts of the Large Underground Xenon (LUX) experiment to directly detect WIMP-xenon recoils.The LUX detector is a 370-kg two-phase time projection chamber (TPC) deployed at the Davis Campus of the 4850’ Level of the Sanford Underground Research Facility. It col- lects scintillation and ionization signals from particle interactions in the liquid xenon (LXe) to measure deposited energy and recoil type. The xenon is purified by circulating through a heated zirconium getter, condensed and evaporated with heat exchangers, and calibrated with internal and external sources to characterize the detector response to gammas, betas, neutrons, and alphas in a keV-MeV energy range.Long, stable operation of the detector at 175 K is accomplished with the thermosyphon cryogenic system, which is a passive, gravity-assisted closed cooling loop. The phase change of a fixed amount of nitrogen transports heat from the detector to a thermal bath of liquid nitrogen (LN) above the cryostat. It delivers 1000 W of cooling power through four loops whose transport tubing fits within a 6-inch diameter tube to cool the cryostat in a water tank 6.5 m below the LN bath. Low-power heaters provide temperature control to within 0.1 K. This system provided months of stable operation underground at 25-slpm xenon circulation with a 5-W heat load.The first WIMP hunt consisted of 85 live-days of data acquisition. Alpha decays from radon were observed and studied to characterize their background contributions to the WIMP analysis. The (a,n) rate and electron recoils from beta decays in the 222Rn chain were found to be sub-dominant to other irreducible backgrounds. All backgrounds were carefully measured to create a model used in the profile likelihood ratio test statistic for the first LUX result that produced the most sensitive WIMP limit to date.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bradley, Adam Wade
Contributors dc:contributor
  • Shutt, Tom
  • Akerib, Dan

Subjects

dc:subject × 11

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Bradley, Adam Wade. LUX Thermosyphon Cryogenics and Radon-Related Backgrounds for the First WIMP Result. doctoral thesis, Case Western Reserve University School of Graduate Studies, 2014. http://rave.ohiolink.edu/etdc/view?acc_num=case1390314556