Case Western Reserve University School of Graduate Studies
Integrated Microsystems for High-Fidelity Sensing and Manipulation of Brain Neurochemistry
Abstract
dc:descriptionThis project has developed two integrated microsystems fabricated in a 0.35-µm two-poly four-metal CMOS process for high-fidelity sensing and manipulation of brain neurochemistry. In particular, first, a system-on-chip (SoC) has been developed for neurochemical pattern generation <i>in vivo</i>. This SoC uniquely integrates electrical stimulation with embedded timing management for generation of neurochemical patterns and 400V/s fast-scan cyclic voltammetry (FSCV) sensing at a carbon-fiber microelectrode (CFM), for subsequent assessment of fidelity in the generated profiles, and manages a novel switched-electrode scheme that eliminates the possibility of large stimulus artifacts adversely affecting electrochemistry. The SoC also leverages the discontinuous sampling inherent in FSCV to reduce the sensing power consumption by 87.5% to 9.3µW from 2.5V using a duty-cycled, 3rd-order, continuous-time, delta-sigma modulator (CT-ΔΣM) with an input-referred noise current of 78pA<sub>rms</sub> (dc – 5 kHz) within an input current range of ±950nA. Utilizing a transfer function that relates electrical stimulation of dopamine axons traversing the medial forebrain bundle (MFB) to evoked extracellular dopamine dynamics in the dorsal striatum of the forebrain, the correlation coefficient between predicted and measured dopamine temporal profiles was found to be 0.95 in an anesthetized rat.Next, the second SoC has been developed for closed-loop regulation of brain dopamine. This SoC uniquely integrates neurochemical sensing, on-the-fly chemometrics, and feedback-controlled electrical microstimulation to mimic a “neurochemical thermostat” by maintaining brain levels of electrically evoked dopamine between two user-set thresholds. The SoC incorporates a 90µW, custom-designed, digital signal processing (DSP) unit for real-time processing of neurochemical data obtained by 400V/s FSCV at a CFM. Specifically, the DSP unit executes a chemometrics algorithm based upon principal component regression (PCR) to resolve in real time electrically evoked brain dopamine levels from pH change and CFM background-current drift, two common interferents encountered with FSCV at a CFM in vivo. Further, the DSP unit directly links the chemically resolved dopamine levels to the activation of the electrical microstimulator in on-off-keying (OOK) fashion. Measured results from benchtop testing, flow injection analysis (FIA), and biological experiments with an anesthetized rat are presented.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- EECS - Electrical Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 2015
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Bozorgzadeh, Bardia
- Contributors dc:contributor
-
- Mohseni, Pedram
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case1432223568