Back to search

Cleveland State University

Determining the Transport Enhancement of Sodium Fluorescein in Mechanically-Loaded Canine Tibia

Abstract

dc:description

Quantitative research concerning the impact of mechanical loading on the transport properties of bone has several critical applications. One such application is the effect of a microgravity environment, where the lack of mechanical forces on bone has been shown to negatively impact both growth and repair. A method has been developed in our lab that can potentially allow for the measurement of the effective permeability of large molecules (i.e., 300-15,000 Da in size) in bone tissue under both unloaded and mechanically loaded conditions. In proof-of-concept experiments, previous students have measured the effective diffusivity of the model solute, sodium fluorescein (376 Da) in a sample of unloaded bone tissue. A mechanical loading system has been modified to measure the effective permeability of sodium fluorescein for a bone beam undergoing four point bend testing in a bioreactor system in order to quantify the effect of mechanical loading on solute transport. The first goal of the present work was to validate that deflection of the bone beam was occurring at applied displacements of less than 40 µm. Once the deflection of the bone beam in the mechanical loading system was validated, the primary objective of measuring the transport parameter for sodium fluorescein in canine cortical bone under unloaded and loaded conditions could be achieved. The average value and standard error of this parameter for loaded samples was determined to be 3.70x10<sup>-8</sup>±1.31x10<sup>-8</sup> cm<sup>2</sup>s<sup>-1</sup> (n=5), and 6.59x10<sup>-9</sup>±2.46x10<sup>-9</sup> cm<sup>2</sup>s<sup>-1</sup> (n=4) for unloaded samples. Although a student’s t-test showed that the loaded and unloaded values were not statistically different (p=0.08), this is likely due to the small number of samples. These preliminary results do show that the transport parameter of sodium fluorescein in cortical bone increased by more than factor of 5 with the addition of mechanical loading.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Chemical Engineering
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Washkewicz College of Engineering
Grantor dc:publisher
Cleveland State University
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zak, Andrew Joseph
Chair dc:contributor.committeechair
  • Belovich, Joanne

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Zak, Andrew Joseph. Determining the Transport Enhancement of Sodium Fluorescein in Mechanically-Loaded Canine Tibia. masters thesis, Cleveland State University, 2015. http://rave.ohiolink.edu/etdc/view?acc_num=csu1449314893