Dosimetric Calculation of a Thermo Brachytherapy Seed: A Monte Carlo Study
Abstract
dc:descriptionResearch has proven that Hyperthermia and Radiation work in synergy with one anotherin killing cancer cells, with heat killing hypoxic cells and radiation killing oxygenatedcells.The objective of this research project was twofold: a) to model the Best Medical, Inc.seed Model 2301 125I seed and run in Monte Carlo N-Particle Transport Code version 5(MCNP5). To compute the American Association of Physicists in Medicine (AAPM)Task Group 43 (TG43) factors using this model. Then compare the results to Book valuesas published by Sowards et al and the TG43 report. b) To model the newthermobrachytherapy seed and run the TG-43 factors, comparing the results to both theBook values and the calculated Best Model seed.In Liquid Water, the dose rate constant calculated for the Best model Seed is 1.056±0.0055 Gy*h-1*U-1 (Book value of 1.01: with a percentage difference of 4.6%). Thevalue measured for thermobrachytherapy seed#1 is 1.057 ±0.031 cGy*h-1U-1and thermobrachytherapy seed#2 is 1.058 ±0.031 cGy*h-1U-1The value obtained for thermobrachytherapy Seed#1 varies by 0.091% from themeasured Best Model value and by 4.69% from Best Model book value. Continuing thecomparison, the value obtained for thermobrachytherapy Seed#2 varies by 0.15% fromthe measured Best Model value and by 4.75% from Best Model book valueIn Solid Water, the dose rate constant calculated for the Best model seed is 1.03 ±0.031cGy*h-1*U-1 (Book value of 0.98: with a percentage difference of 5.1%). The valuemeasured for thermobrachytherapy seed#1 is 1.03 ±0.031 cGy*h-1U-1 andthermobrachytherapy seeds#2 is1.029 ±0.031 cGy*h-1*U-1. The value obtained forthermobrachytherapy Seed#1 varies by 0.01% from the measured Best Model seed andby 5.1% from Best Model book value. The value obtained for thermobrachytherapySeed#2 varies by 0.09% from the measured Best Model value and by 4.97% from BestModel book value.The Correction/Multiplicative Factor (conversion of dose rate constant) between theSolid Water and liquid water for the calculated Best Model 125I seed #2301 is 1.026(Book Value of 1.05). Thermobrachytherapy Seed#1 has a factor of 1.026 andThermobrachytherapy Seed#2 is 1.028. It once again shows close agreement for bothSolid and liquid Water.Radial dose function was taken at 0.1cm to 10cm at 0.1cm intervals to 1cm and then at0.5cm interval to 10cm.The figures for Radial dose functions can be compared and itshows superposition of the data points confirming good agreement between the measuredand the book value. The Radial dose function from the two brachytherapy seeds is furthercompared to the measured values and book values of the Best Model seed and again agood agreement is seen in the results.Anisotropy Function was calculated for all the three seeds in both Liquid and SolidWater. The function was calculated from 1cm to 7cm in 1cm increments at 0°-90° at 10°increments. Similar to comparisons in the radial function, anisotropy function data pointswere superimposed confirming good agreement between the measured value for BestModel and the book value. The anisotropy function from the two brachytherapy seeds isfurther compared to the measured values and book values of the Best Model seed andagain a good agreement is seen in the results.In liquid water, the Source Anisotropy Constant for Best Model 2301 Seed is 0.935,thermobrachytherapy seed#1 is 0.923 and thermobrachytherapy seed#2 is 0.927. For theBest Model 2301, the value deviates by 4.5% from the Book value. The values forthermobrachytherapy seed#1 deviates from the Monte Carlo calculated Best Model 2301125I Seed by 1.28%, and from the Book value by 4.6%. Thermobrachytherapy seed#2deviates from the Monte Carlo calculated Best Model 2301 125I Seed by 0.8% and theBook value by 5.4%. In Solid Water, the Source Anisotropy Constant for Monte Carlocalculated Best Model 2301 Seed is 0.926. Thermobrachytherapy seed#1 has a value of0.918 and thermobrachytherapy seed#2 has a value of 0.927.In terms of deviation, the Monte Carlo calculated Best Model seed deviates 4.5% fromthe book value for the same seed. Thermobrachytherapy seed#1 deviates from the MonteCarlo calculated Best Model 2301 125I Seed by 0.08% and the Book value by 5.4%.Thermobrachytherapy seed#2 deviates from the Monte Carlo calculated Best Model 2301125I Seed by 0.3% and the Book value by 4.8%Analyzing the data, there is very little difference between thermobrachytherapy seed#1and thermobrachytherapy seed#2 in comparison to one another. The data between the twoseeds is very comparable. Also, the results are quite similar, in terms of error percentage,between the Book values and measured value for the Best Model 2301 125I Seed. It is alsoimportant to note that the seed’s TG-43 factors have not deviated too much from theestablished data on the Best Model Seed. This ensures that the radio-activity from theseed is still established and there isn’t a loss of activity around the seed.
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Biomedical Sciences (MSBS)
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- College of Graduate Studies
- Grantor dc:publisher
- University of Toledo Health Science Campus
- Year dc:date
- 2008
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Khan, Nadeem
- Chair dc:contributor.committeechair
-
- Parsai, E. Ishmael
Subjects
dc:subject × 9Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=mco1228860927