University of Toledo Health Science Campus
A Comparative Analysis of Conventional MLC Based IMRT and Solid Compensator Based IMRT Treatment Techniques
Abstract
dc:descriptionIntensity Modulation Radiation Therapy (IMRT) using multi leaf collimation systems hasrevolutionized the delivery of radiation therapy. However, these treatments may result indelivery of very large monitor units (MUs) through very small fields where electronicequilibrium may be compromised. This also raises some concerns in terms of thescattered dose to areas outside the main treatment volume. The goals of this study were toevaluate the clinical differences of solid compensator and MLC based IMRT treatments.The investigation was extended to compare fluence maps at prescription plane, thedelivery time, monitor unit requirements, and deposited dose to outside of the targetvolume. The ADAC Pinnacle inverse planning system was used to generate MLC basedIMRT plans and using the .decimal software package, generating the compensator basedIMRT plans. Treatment plans were generated for prostate, adrenal gland, brain, and headand neck cases. Delivery of treatment plans were performed on a Rando phantom andmosfet dosimeters, TLDs, and films were used to compare measured doses of MLC andsolid IMRT treatments. For the more complex plans the solid compensators resulted in26.7% fewer monitor units and delivery time was reduce in half when compared with mlcplans. However for relatively simple IMRT plans such as prostate boosts or adrenalgland plans where the target has a relatively simple cylindrical shape the mlc plansresulted in an average of 41.6% fewer MUs and required about 16% less time to deliverthan the solid compensator plans. Mosfet skin dose analysis showed that the solidcompensators resulted in an average of 17.5% less dose. Film analysis also showed thatCompensator plans delivered less out of field fluence. Based on the results it is evidentthat solid compensators are a viable IMRT treatment option when considering complex target arrangements that require many beams segments. For relatively simple planswhich result in fewer and larger beam segments compensator based plans showed noadvantage over mlc plans in regards to MUs and treatment time.
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Biomedical Sciences (MSBS)
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- College of Medicine
- Grantor dc:publisher
- University of Toledo Health Science Campus
- Year dc:date
- 2009
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Khadija, Murshed
- Chair dc:contributor.committeechair
-
- Parsai, E. Ishmael
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=mco1264434257