Back to search

University of Toledo Health Science Campus

Dose Modification Factor Analysis of Multi-Lumen Brachytherapy Applicator with Monte Carlo Simulation

Abstract

dc:description

Multi-lumen applicators like the Contura (SenoRx, Inc.) are used in partial breast irradiation (PBI) brachytherapy in instances where asymmetric dose distributions are desired, for example, when the applicator surface-to-skin thickness is small (<7mm). In these instances, the air outside the patient and the lung act as a poor scattering medium, scattering less dose back into the breast tissue which affects the dose distribution. Many commercial treatment planning systems do not correct for tissue heterogeneity, which results in inaccuracies in the planned dose distribution. This deviation has been quantified as the dose modification factor (DMF), equal to the ratio of the dose rate at 1cm beyond the applicator surface, with homogenous medium, to the dose rate at 1cm with heterogeneous medium. This investigation intends to model the Contura applicator with the Monte Carlo N-Particle code (MCNP, Los Alamos National Labs), determine a DMF through simulation, and correlate to previous measurements. Taking all geometrical considerations into account, an accurate model of the Contura balloon applicator was created in MCNP. This model was used to run simulations of symmetric and asymmetric plans. The dose modification factor was found to be dependent on the simulated water phantom geometry, with cuboid geometry yielding a max DMF of 1.0664. The same measurements taken using a spherical geometry water phantom gave a DMF of 1.1221. It was also seen that the difference in DMF between symmetric and asymmetric plans using the Contura applicator is minimal.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Biomedical Sciences (MSBS)
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
College of Medicine
Grantor dc:publisher
University of Toledo Health Science Campus
Year dc:date
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Williams, Eric
Chair dc:contributor.committeechair
  • Pearson, David

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Williams, Eric. Dose Modification Factor Analysis of Multi-Lumen Brachytherapy Applicator with Monte Carlo Simulation. masters thesis, University of Toledo Health Science Campus, 2012. http://rave.ohiolink.edu/etdc/view?acc_num=mco1352570600