Back to search

Miami University

I. FLOW INJECTION CAPILLARY ELECTROPHORESIS USING ON-LINE ENZYMATIC AND DYE INTERACTION REACTIONS II. MINI—SOLID PHASE EXTRACTION OF PHARMACEUTICALS AND PHOSPHOLIPIDS IN CONJUNCTION WITH NANO-ELECTROSPRAY MASS SPECTROMETRY

Abstract

dc:description

The first two projects describe new applications of flow injection capillary electrophoresis (CE). The first study focuses on the determination of lactate or oxalate using injected lactate oxidase (LO) and peroxidase with UV detection. Two reactions, catalyzed by (LO) and peroxidase, are initiated by a single injection of the enzymes and the substrate 2,2’-azino-bis(3-ethylene-thiazoline-6-sulfonic acid) (ABTS) into the capillary previously filled with the sample (lactate or lactate-oxalate mixture) and the running buffer containing NADH. The oxidized ABTS product upon reaction with NADH is converted to NAD+, which is detected at 266 nm with a sample throughput of 7 min including wash steps. Linearity for lactate is established from 0.0025 – 1mM and serum samples are analyzed with an average recovery of 101%. This method can also be applied to the determination of oxalate as an inhibitor of LO. The second topic describes the determination of the concentration of cardiolipin using CE with on-line N-nonylacridine orange (NAO) dye interaction and spectrophotometric detection at 497 nm. Other phospholipids do not interfere and a detection limit of 0.05 ìM was found. In a blind study, actual mitochondrial cell membrane samples in the µL range, taken from cells before or after UV light exposure, are analyzed using the CE method. The last two topics describe preconcentration of pharmaceuticals and phospholipids with nano-electrospray ionization mass spectrometry (nano-ESI MS). An analytical method is developed for the quantitative determination of dicyclomine in serum with cyclopentolate as the internal standard by off-line nano-ESI MS with reversed phase mini-solid phase extraction (mini-SPE). Different length (0.5cm, 1cm) reversed phase (C4 and C18) mini-SPE cartridges are prepared by packing gel-loader pipette tips for optimization of the preconcentration effect. A factor of 100 is possible using the 1 cm C18 or C4 cartridge. Spiked serum samples are quantitatively determined using the C18 cartridge. Preconcentration of phospholipids is first studied for nano-ESI MS by weak anion exchange SPE. With aminopropyl SPE, detection limits are lowered 2-2000 times for different phospholipids as compared to no SPE. With aminopropyl mini-SPE and mixed mode C18/aminopropyl (1:1) mini-SPE, the detection limits for eight different phospholipids are lowered another factor of 5 better (about 0.05 to 5 pmol/ìL) than those for weak anion exchange SPE. Linear calibration curves are able to be established.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Chemistry and Biochemistry
Grantor dc:publisher
Miami University
Year dc:date
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Qi, Lining
Advisor dc:contributor.advisor
  • Danielson, Neil

Subjects

dc:subject × 9

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Qi, Lining. I. FLOW INJECTION CAPILLARY ELECTROPHORESIS USING ON-LINE ENZYMATIC AND DYE INTERACTION REACTIONS II. MINI—SOLID PHASE EXTRACTION OF PHARMACEUTICALS AND PHOSPHOLIPIDS IN CONJUNCTION WITH NANO-ELECTROSPRAY MASS SPECTROMETRY. doctoral thesis, Miami University, 2003. http://rave.ohiolink.edu/etdc/view?acc_num=miami1059077676