Back to search

The Ohio State University

A study of ion-moleucle reactions in a dynamic reaction cell to improve elemental analysis with inductively coupled plasma-mass spectrometry

Abstract

dc:description

An inductively coupled plasma dynamic reaction cell mass spectrometer (ICP-DRC-MS) was used to study reactions between elemental analyte ions, elemental and polyatomic background ions (such as argides (ArM+), oxides (MO+) and doubly charged species (M2+)) with NH3 and C2H4. NH3 reduced most ion signals from a deionized water sample (DI H2O), argides (ArM+), oxides (MO+) and doubly charged species (M2+). C2H4 was less powerful at reducing background ion signals from a deionized water sample (DI H2O) and generated new in-cell product ions, increasing the background signal at many masses. Loss of ion signal rates were calculated and reported in orders of magnitude per (mL/min increase in reaction gas flow rate (in Argon equivalent units)). NH3 attenuated most elemental ion signals between 1 and 3 orders of magnitude although rates up to five orders of magnitude were seen. C2H4 reduced most elemental ion signals up to 2 orders of magnitude although rates up to 3 orders of magnitude were seen. The products of reactions between NH3 and 70 elemental ions were identified, categorized and quantified. The major product ions from C2H4 and monoisotopic elemental ions greater than 100 amu were identified and categorized. Effects of the Mathieu parameter q (or RPq) on elemental and product ion signals in an NH3 pressurized reaction cell were studied. Comparisons of product ion prevention via RPq value and kinetic energy discrimination were made. A simulation of ion signal (sample and blank) and estimated detection limits (EDL) versus reaction gas flow rate was created and designed to aid selection of the optimum reaction gas flow rates. A strategy for method development with the ICP-DRC-MS is presented. Results using this strategy are shown for the detection of 27Al+ in the presence of 11B16O+, detection of 51V+ in the presence of 35Cl16O+. Also included are the results for the detection of 75As+ as 75As16O+ and 80Se+ as 80Se16O+ at masses 91 and 96, respectively, to avoid the spectral overlaps 40Ar35Cl+ and 40Ar2+ at masses 75 and 80, respectively. The ICP-DRC-MS was used to precisely measure 60Ni/58Ni with 0.091% RSD and a counting statistics limit of 0.087%.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Chemistry
Grantor dc:publisher
The Ohio State University
Year dc:date
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jones, Deanna M. Rago
Advisor dc:contributor.advisor
  • Olesik, Susan

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Jones, Deanna M. Rago. A study of ion-moleucle reactions in a dynamic reaction cell to improve elemental analysis with inductively coupled plasma-mass spectrometry. doctoral thesis, The Ohio State University, 2007. http://rave.ohiolink.edu/etdc/view?acc_num=osu1180534215