Back to search

The Ohio State University

MRI-Based Attenuation Correction for PET Reconstruction

Abstract

dc:description

In this study we proposed and developed a simple attenuation mapping approachbased on magnetic resonance imaging (MRI) for the purpose of reconstructing positron emission tomography (PET) images in PET/MRI imaging devices. After experimental development, an in vivo calibration was performed by whole body scanning of five beagles on both a PET/CT and MRI. The attenuation was determined by using an automatic segmentation algorithm to segment regions of air, lung, soft tissue, and bone and assigning them values of 0.002 cm-1, 0.030 cm-1, 0.098 cm-1, and 0.130 cm-1 respectively. The CT attenuated PET images and the MRI attenuated PET images were very similar, and average standardized uptake values (SUV) for mostregions of interest differed by 1% - 6%. Also, mean relative differences (MRD) between the images were between 5% and 9% for most regions. The only exception isbone, where the three region MRI attenuated PET images had an SUV 9% less on average than the CT attenuation images, and the MRD averaged 14%. Also, additionalsegmentation of bone in the four region MRI attenuated PET images reduced the SUV difference to 3% and the MRD to 6%. However, the differences between the CT and 3 region attenuations were much smaller than the differences between CT attenuated and unattenuated PET images, which had average SUVs of 1-37% and MRDs of 10-45%. In particular the spine had an average SUV difference of 29% and MRD of 45%. Therefore, despite the improvements in the four region segmentation, the three region segmentation without delineation of osseous tissues produces high quality images that are sufficient for most expected clinical purposes.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
The Ohio State University
Year dc:date
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Steinberg, Jeffrey
Contributors dc:contributor
  • Honscheid, Klaus
  • Knopp, Michael

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Steinberg, Jeffrey. MRI-Based Attenuation Correction for PET Reconstruction. doctoral thesis, The Ohio State University, 2008. http://rave.ohiolink.edu/etdc/view?acc_num=osu1219938403