Back to search

The Ohio State University

Simulation-Based Stability Tests in Total Knee Arthroplasty: Are Component Alignment, KneeLaxity, and Tibiofemoral Contact Forces Related?

Abstract

dc:description

Total knee arthroplasty (TKA) is known to be a successful procedure that can treat pain and disfunctioncaused by knee osteoarthritis (KOA). However, approximately 20% of patients are dissatisfied aftersurgery, with complications that have been linked to variable intraoperative procedures such asprosthetic component alignment and soft-tissue balancing techniques. The concept of kinematicalignment has been introduced to serve as an alternative to traditional mechanical alignment, where allpatients’ bone cuts are made in the same way to restore a straight hip-knee-ankle line. Kinematicalignment instead aims to restore the anatomy of the native knee, without the need to balance the softtissues. While many methods regarding soft-tissue balancing are subjective to surgeon decisions, newtechnology released by OrthoSensor serves to take tibiofemoral force measurements in eachcompartment of the knee during a passive range of motion, claiming that equal contact forces withinvarious thresholds presume knee balance. However, biomechanical knee balance is defined using theamount of knee motion resulting from a known applied force, which we have quantified with a novelknee stability device. The purpose of this study was to investigate the relationship of these contact forcemeasurements to biomechanical knee laxity and prosthetic component alignment, as well as to explorethe clinical utility of using contact forces and component alignments to predict knee laxity. Theserelationships were explored by creating a model of the lower limb in OpenSim 4.0 that incorporatedcontact meshes of the prosthetic components and varying properties of ligament stiffnesses torepresent five different types of knees. 790 forward dynamic simulations were run at multiple flexionangles, applying increasing and decreasing torque to move the knee in the varus-valgus direction.Correlations were calculated between contact forces, knee laxity, and component alignment, and forward step-wise regressions were done to try to predict laxity using inputs of contact and alignment.Balanced contact forces did not show a consistent association with balanced knee laxity, but highercontact forces were generally associated with decreased laxity. However, contact measurements did nothave a consistent significant effect in the prediction of knee laxity, which adds to the lack of support forthe utilization of these measurements. Tibiofemoral contact was also quite sensitive to componentalignment changes, which supports the idea that kinematically-aligned TKAs should not use a forcetarget when balancing the knee, as patient-specific alignment entails patient-specific contact forces.Overall, the relationships between tibiofemoral contact and biomechanical knee function wereinconsistent and therefore the use of these contact forces in soft-tissue balancing is not supported.More research should be done in modeling these forces during daily activities to explore a relationshipbetween contact forces and active functionality.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor dc:publisher
The Ohio State University
Year dc:date
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Delventhal, Brooke
Contributors dc:contributor
  • Siston, Robert

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Delventhal, Brooke. Simulation-Based Stability Tests in Total Knee Arthroplasty: Are Component Alignment, KneeLaxity, and Tibiofemoral Contact Forces Related?. masters thesis, The Ohio State University, 2019. http://rave.ohiolink.edu/etdc/view?acc_num=osu1574422948246589