An Evaluation of Corrosion Sensors for the Monitoring of the Main Cables of the Anthony Wayne Bridge

Abstract

dc:description

The Anthony Wayne Bridge is a suspension bridge located in Toledo, Ohio currently undergoing an extensive rehabilitation project. Internal inspection revealed corrosion of the steel wires within the bridge’s main cable. The bridge operators have elected to pursue the installation of a dehumidification system. Such a system injects dry air into the cable to lower the relative humidity and stop the corrosion process. The research presented in this thesis investigates the use of the Analtom AN110 corrosion sensor and its applications on the Anthony Wayne Bridge. Dehumidification systems require extensive monitoring systems to ensure their effectiveness and proper operation. The AN110 corrosion sensor uses linear polarization resistance (LPR) technology to measure corrosion rates in real time. Such measurements could potentially provide data valuable in ensuring the effectiveness and progress of the drying-out process. Included is an extensive review of the bridge’s rehabilitation process, a literature review of dehumidification and the application of LPR technology, and laboratory testing of the corrosion sensor. Laboratory testing involved the exposure of the sensor to cyclic relative humidity to observe the relationship between corrosion rate and relative humidity. The use of the AN110 corrosion sensor in the monitoring of the future dehumidification system on the Anthony Wayne Bridge is recommended. Among other factors, testing results showed a clear and consistent relationship between the recorded corrosion rate and the relative humidity. The sensor functions as expected and confirms the existing understanding of the effect of relative humidity on the corrosion of steel.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Civil Engineering
Grantor dc:publisher
University of Toledo
Year dc:date
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Colony, Charles W., Colony
Chair dc:contributor.committeechair
  • Nims, Douglas

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Colony, Charles W., Colony. An Evaluation of Corrosion Sensors for the Monitoring of the Main Cables of the Anthony Wayne Bridge. masters thesis, University of Toledo, 2016. http://rave.ohiolink.edu/etdc/view?acc_num=toledo1471543246