Technische Universität Dresden
Experimental Investigations on Bubbly Two-Phase Flow in a Constricted Vertical Pipe
Abstract
dc:description.abstractGas-liquid two-phase flows occur in many industrial applications and apparatuses. The design and optimization of such apparatuses and processes requires the numerical simulation of two-phase flows. However, two-phase flow simulations are still a challenging task, especially for industrial scales. Here, the simulation of large flow domains and high Reynolds number flows require a reduction of the resolved time-scales and length-scales by a high level of modeling to decrease the computational effort. Therefore, physics-based models are needed to depict the complex transport processes between the phases. Thus, two-phase flows are the object of ongoing research. Up to now, the majority of closure models for turbulence, interfacial forces or bubble breakup and coalescence were validated against experimental data derived from experiments in simple flow channel geometries like straight pipes. Their application for the simulation of two-phase flows with three-dimensional flow structures like e.g. recirculating areas, flow separation or strong velocity gradients requires constant experimental validation and further development. Hence, improved experimental methods are required for investigations of gas-liquid two-phase flows to provide reliable data for further development and validation of numerical flow simulation models. Therefore, experiments were performed in a constricted pipe under bubbly two-phase flow conditions. Three-dimensional flow structures were created by two types of flow constrictions for a variety of gas and liquid superficial velocities up to jg = 0.1400 m⋅s-1 and jl = 1.6110 m⋅s-1. The flow fields upstream and downstream of the flow constrictions were studied using ultrafast X-ray tomography and hot-film anemometry to obtain cross-sectional phase distribution, bubble characteristics and liquid velocity. The analysis of the ultrafast X-ray tomography image data was significantly improved by development of a histogram-based gas holdup calculation. Furthermore, the spatial dependence of the axial image plane distance was studied to improve the determination of axial bubble velocities and, thus, bubble sizes. The experimental method was advanced by simultaneous application of ultrafast X-ray tomography and hot-film anemometry. Eventually, the experimental data was compared to state-of-the-art Euler/Euler two-fluid simulations. The simulations were performed in the framework of a parallel doctoral thesis in the Experimental Thermal Fluid Dynamics department at the Helmholtz-Zentrum Dresden – Rossendorf by Ms. Sibel Tas-Koehler following the baseline approach. The results were compared in terms of the phase distribution, bubble sizes and gas velocity for two operating conditions using the homogeneous multiple size group model.
Degree
thesis:*- Level thesis:degree_level
- thesis.doctoral
- Department thesis:degree_department
- Fakultät Maschinenwesen
- Grantor dc:publisher
- Technische Universität Dresden
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Neumann-Kipping, Martin
- Advisor dc:contributor.advisor
-
- Hampel, Uwe
Subjects
dc:subject × 9Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- free
- info:eu-repo/semantics/openAccess
- Language dc:language.dcterms_iso639_2
- eng
Identifiers
dc:identifier.*- Dc Publisher Identifier
- 2024114-8
- Ddb Identifier Erstkat Id
- 1815980338