Queen's University at Kingston
Reinforcement learning-based energy management of battery-supercapacitor hybrid energy storage systems in electric vehicles
Abstract
dc:description.abstractBattery-supercapacitor hybrid energy storage systems (HESSs) combine the high energy density of batteries with the high power capability of supercapacitors. Their performance depends on both the power-converter architecture and the energy-management system (EMS). This thesis investigates the coordinated design of converter architecture and EMS for electric vehicles (EVs). First, HESS converter architectures are classified as dual-stage, single-stage, and quasi-stage systems, while EMS methods are reviewed as rule-based, optimization-based, machine-learning-based, and hybrid approaches. The review shows that converter topology determines the feasible source-power paths, control variables, and operating constraints available to the EMS. The first original study considers a fully active dual-stage HESS with separate bidirectional dc-dc converters. This structure enables independent source-current regulation and a continuous battery-current action. Deep deterministic policy gradient, soft actor-critic, and proximal policy optimization (PPO) are compared under a common plant, reward function, and training framework. The agents are trained using the Worldwide Harmonized Light Vehicles Test Procedure (WLTP) and evaluated under the unseen Urban Dynamometer Driving Schedule (UDDS). Among the evaluated learning methods, PPO provides the lowest battery root-mean-square current, current standard deviation, and peak discharge current. The second study considers a neutral-point-clamped-derived single-stage multi-source inverter. Since the battery and supercapacitor currents cannot be commanded independently, the EMS is formulated as discrete selection among three space-vector-modulation operating modes. A discrete-action PPO policy is trained using UDDS and evaluated under the unseen WLTP and New York City Cycle. Relative to a rule-based EMS, it reduces battery root-mean-square current by 35.37% and 39.33%, and peak absolute battery current by 27.78% and 33.49%, under the two cycles, respectively. The fixed trained policies are also evaluated using OPAL-RT software-in-the-loop implementations. Overall, the results show that the EMS formulation should reflect the physical control freedom provided by the converter architecture: continuous source-current allocation is enabled by the investigated dual-stage system, whereas topology-dependent discrete mode selection is adopted for the investigated single-stage system.
Degree
thesis:*- Department dc:contributor.department
- Electrical and Computer Engineering
- Grantor
- Queen's University at Kingston
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Ranjbaran, Parisa
- Advisors dc:contributor.supervisor
-
- Bakhshai, Alireza
- Jain, Praveen
Subjects
dc:subject × 4Rights
dc:rights- Statement dc:rights
-
- Attribution-NonCommercial-NoDerivatives 4.0 International
- Licence dc:rights.uri
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1974/37055