Back to search

University of Saskatchewan

Simulation of a 3-Fluid Membrane Liquid Desiccant Air-Conditioning System

Abstract

dc:description.abstract

A liquid-to-air membrane energy exchanger (LAMEE) is able to simultaneously cool and dehumidify air by transferring heat and moisture between the air stream and a liquid desiccant solution. The heat and moisture transfer rates in a LAMEE can be enhanced if a third fluid stream is used to control the desiccant solution temperature in the LAMEE. A LAMEE with a third fluid stream is known as a 3-fluid LAMEE. Published studies on 3-fluid LAMEEs are limited to experiments on the exchanger under limited test conditions. This thesis focuses on simulating the performance of a 3-fluid LAMEE in a membrane liquid desiccant air-conditioning (M-LDAC) system. In the thesis, empirical correlations are developed based on experimental data to model the 3-fluid LAMEE and the limitations of the empirical model are evaluated. Subsequently, the 3-fluid and 2-fluid M-LDAC systems are simulated and compared at six different dehumidification load conditions. The simulation results show that, for most conditions, the 3-fluid M-LDAC system is able to meet the dehumidification load with a lower energy input than the 2-fluid M-LDAC system. The energy efficiency of the 2-fluid M-LDAC system is higher than the 3-fluid M-LDAC system at only the lowest dehumidification load. The 3-fluid and 2-fluid M-LDAC systems are paired with a radiant cooling system to condition a small office building located in a hot-humid climate (Miami, Florida). Both the 2-fluid and 3-fluid systems provide acceptable thermal environment within the office building but the energy consumption of the 2-fluid system is 50% higher than the 3-fluid system. This thesis concludes that the 3-fluid M-LDAC system may be more suitable than the 2-fluid M-LDAC system for hot and humid climates and in buildings with high dehumidification loads.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department thesis:degree_department
Mechanical Engineering
Grantor
University of Saskatchewan
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Storle, Devin 1991-
Advisor dc:contributor.advisor
  • Simonson, Carey
Committee members dc:contributor.committeemember
  • Torvi, David
  • Guo, Huiqing
  • Faried, Sherif O.

Subjects

dc:subject × 6

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10388/8286

Chain of custody

source
Harvested from
University of Saskatchewan
Base URL
harvest.usask.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Storle, Devin 1991-. Simulation of a 3-Fluid Membrane Liquid Desiccant Air-Conditioning System. Masters thesis, University of Saskatchewan, 2017. https://hdl.handle.net/10388/8286