Back to search

University of Saskatchewan

X-RAY INDUCED EFFECT ON CHARGE CARRIER TRAPPING LIFETIME OF a-Se PHOTOCONDUCTORS AND THE RECOVERY PROCESS

Abstract

dc:description.abstract

Amorphous selenium (a-Se) alloy x-ray detectors are currently used in commercial mammographic detectors for breast cancer detection and diagnosis. They have been only recently commercialized and there are now at least five companies manufacturing these detectors. This work focuses on the study of the X-ray induce effects on the carrier trapping lifetime in a-Se, and the recovery process of the X-ray induced damage in the bulk of a-Se samples. The x-ray dose effect on the carrier trapping lifetime was studied alongside the temperature effect on the induced x-ray damage and recovery process. The carrier trapping lifetime reduces as the accumulated dose deposited in the a-Se samples increases. Upon the cessation of x-ray exposure, carrier lifetime recovered slowly (over many hours) back to its original state. The damage was not permanent. Several a-Se detectors samples have been exposed to high doses of x-ray and the recovery process has been observed under different temperature, 23.5 oC and 35.5 oC. The time of flight (TOF) measurement technique was employed to measure the carrier drift mobility  and the interrupted filed time of flight (IFTOF) technique was used to measure the carrier trapping lifetime . All samples used in this project are pure a-Se for hole transport measurements, a-Se: 0.3%: 2.5ppm Cl and a-Se: 0.5%: 10ppm Cl for electron transport measurements. Sample thickness ranges from 50 μm to 200 μm with a variance of ±5 μm at different positions on the sample. The applied dose rate during the x-ray irradiation ranges from 1.9 Gy/s to 2.5 Gy/s. The difference in dose rate does not affect the change in the hole trapping lifetime but has a non-significant effect on the electron trapping lifetime. The rate of decrease in the hole normalized lifetime is more rapid at 35.5oC than at room temperature (23.5oC). The recovery processes were also observed to be more rapid at the higher temperature.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Electrical Engineering
Department thesis:degree_department
Electrical and Computer Engineering
Grantor
University of Saskatchewan
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Adeagbo, Emmanuel Bamise 1988-
Advisor dc:contributor.advisor
  • Kasap, Safa
Committee members dc:contributor.committeemember
  • Li, Chen
  • Michael, Bradley
  • Anh, Dinh
ORCID person:identifier.orcid

Subjects

dc:subject × 5

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10388/9776

Chain of custody

source
Harvested from
University of Saskatchewan
Base URL
harvest.usask.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Adeagbo, Emmanuel Bamise 1988-. X-RAY INDUCED EFFECT ON CHARGE CARRIER TRAPPING LIFETIME OF a-Se PHOTOCONDUCTORS AND THE RECOVERY PROCESS. Masters thesis, University of Saskatchewan, 2018. https://hdl.handle.net/10388/9776