Back to search

South Dakota State University

Refinement Of Trend-To-Trend Cross Calibration Total Uncertainties Utilizing Extended Pseudo Invariant Calibration Sites (Epics) Global Temporally Stable Target

Abstract

dc:description.abstract

Cross-calibration is an essential technique for calibrating Earth Observation satellite sensors, which involves taking nearly simultaneous images of a ground target to compare uncalibrated sensor to a well-calibrated reference sensor. This study introduces the hyperspectral Trend-to-Trend (T2T) cross-calibration technique utilizing EPICS Cluster 13 Global Temporally Stable (Cluster 13-GTS) as the calibration target, offering better temporal stability than previous targets used in T2T cross-calibration by an absolute difference of 0.4%, between coefficients of variation across all bands excluding CA band. A multispectral sensor-specific normalized hyperspectral profile was developed using the EO-1 Hyperion hyperspectral profile over Cluster 13-GTS to improve Spectral Band Adjustment Factor (SBAF) estimation, capturing sensor-specific Relative Spectral Response (RSR) variations and introducing the ability to use the multispectral sensorspecific hyperspectral profile for calibrating future satellite sensors like Landsat Next with super-spectral bands. SBAFs were derived from EO-1 Hyperion normalized to multispectral sensors, which were interpolated to 1nm, ensuring precise spectral band adjustments following a Monte Carlo simulation approach for uncertainty quantification. Results show that reference sensor-specific hyperspectral profiles at 1nm spectral resolution improve SBAF accuracy and exhibit total uncertainty within 5.8% across all bands and all sensor pairs with L8 as the reference sensor. These findings demonstrate that integrating reference sensor-specific high-resolution hyperspectral data and stable calibration targets im-proves T2T cross-calibration accuracy, supporting future superspectral missions such as Landsat Next.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis - Open Access
Discipline thesis:degree_discipline
Electrical Engineering and Computer Science

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Samaranayake, Minura
Contributors dc:contributor
  • Larry Leigh

Subjects

dc:subject × 1

Rights

dc:rights

Identifiers

dc:identifier.*
Repository record dc:identifier
https://openprairie.sdstate.edu/etd2/1540

Chain of custody

source
Harvested from
South Dakota State University
Base URL
openprairie.sdstate.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Samaranayake, Minura. Refinement Of Trend-To-Trend Cross Calibration Total Uncertainties Utilizing Extended Pseudo Invariant Calibration Sites (Epics) Global Temporally Stable Target. Thesis - Open Access thesis, https://openprairie.sdstate.edu/etd2/1540