Given the poor durability of bioprosthetic heart valves and thrombogenicity of mechanical valves, recent attention has been directed towards synthetic leaflet valves. The work of this thesis forms part of a project to develop a tri-leaflet polyurethane heart valve prosthesis. Two aspects have been addressed: in vitro valve function and durability test methods, and fabrication techniques for polyurethane valves. Existing in vitro valve testing facilities, comprising a hydrodynamic function tester (pulse duplicator) and accelerated fatigue testers, have been upgraded. An improved data acquisition system combined with a computerised control system has been developed for the pulse duplicator. The new system allows valve function to be more efficiently and reliably assessed, and also provides a means for characterising the pulse duplicator and its transducers. Accelerated fatigue testing facilities have been similarly enhanced by the introduction of a computerised data acquisition system. In order to exploit the design potential offered by the use of a synthetic material, an integrated CAD/CAM system has been developed for producing sculptured valve formers. Such formers have been incorporated into injection moulding tools for tri-leaflet polyurethane valves. Polyurethane valves have been moulded, but to date not with sufficiently thin leaflets: the required leaflet thickness (< 150 gm) results in a mould cavity which presents an enormous resistance to flow in the injection moulding process. However, a finite element-based mathematical model has been used to simulate the flow of molten polyurethane into the mould cavity and initial results suggest that it should indeed be possible to injection mould a polyurethane valve and a practicable means of achieving this has been identified. The sculptured formers incorporated into the injection moulding tools have also been used to create dip moulded tri-leaflet polyurethane valves. These dip moulded valves, though difficult to produce consistently, function reasonably well in the pulse duplicator and accelerated fatigue tests are in progress.

Degree

thesis:*
Name dc:type.qualificationname
phd
Level dc:type.qualificationlevel
doctoral-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
1992

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mackay, Tom G.

Rights

Identifiers

dc:identifier.*
Identifier
uk.bl.ethos.324108
T7473

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Mackay, Tom G.. Towards a tri-leaflet polyurethane heart valve prothesis. doctoral-pg thesis, University of Strathclyde, 1992. https://stax.strath.ac.uk/concern/theses/m613mx695