Back to search

University of Toronto

New Approaches to High Efficiency Inductively Coupled Plasma Analytical Atomic Spectrometry

Abstract

dc:description.abstract

Two new strategies have been proposed for reducing the gas and energy consumption of ICP sources, in the first place, and improving their analytical performance, in the second place, for analytical atomic spectrometry. In the first strategy, a system was designed to collect the exhaust argon from the interface of an ICP-MS system, purify it, and recycle it back to the ICP torch. The experiments showed that the argon collection system was capable of withstanding the extreme temperatures of the plasma and collect most of the exhaust gas without disturbing the plasma. In the first stage of purifying the gas, a metal-foam heat exchanger coupled with a Peltier cooler was used to freeze the water content of the exhaust gas. In the second stage, a titanium-based heated filter was used to capture the other contaminants. The purification system was shown to be capable of purifying the exhaust argon for several hours of operation. In the second strategy, a new ICP torch was developed with significant reduction in gas and power consumption, but better analytical performance. Computer simulations were used extensively to design and optimize the torch based on the flow patterns, heat transfer, and electromagnetic field. This approach led to a new generation of ICP torches with a “conical” geometry. The new torch could work with up to 70% reduction in gas/energy consumption, at least 4 times higher power density, and a more stable plasma in comparison with the conventional “cylindrical” torches. Based on spectroscopic measurements, in comparison with the common Fassel-type torches, the new torch exhibited 1000–1700 K higher excitation/rotational temperature, 3 times higher robustness, 5 times higher electron density, less interference from easily-ionizable elements, and equal/better detection limits in multi-element analysis. It was further demonstrated that the whole vaporization/atomization/ionization of sample species could be completed in a shorter time using the new torch. Analyzing metal-tagged beads/cells with a commercial CyTOF2 mass cytometer showed that 50% reduction in event length and 2 times higher sensitivity could be achieved using the new torch. These improvements can potentially lead to higher sample throughput and shorter time of analysis per sample.

Degree

thesis:*
Department dc:contributor.department
Mechanical and Industrial Engineering
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Alavi, Sina
Advisor dc:contributor.advisor
  • Mostaghimi, Javad

Subjects

dc:subject × 6

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1807/95654

Chain of custody

source
Harvested from
University of Toronto
Base URL
utoronto.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Alavi, Sina. New Approaches to High Efficiency Inductively Coupled Plasma Analytical Atomic Spectrometry. 2018. https://hdl.handle.net/1807/95654