Abstract
dc:description.abstractIn this study, the thermal resistance, flexural behavior, and impact resistance via hurricane impact loads of two-wythe precast concrete composite sandwich beams comprised of an intermediate carbon-fiber epoxy inter-facially bonded to a dual Hybrid Matrix Composite (HMC) were investigated as an affordable alternative for enhancing thermal and mechanical (debris-impact and flexural) properties. The study is a precursor to the design of Precast Concrete Sandwich Panels (PCSP). HMC is a chemical reaction between a thermosetting epoxy network and a fast-setting, yet highly reactive, isocyanate-amine system at a pre-polymerized stage. The interfacial reaction of HMC is a function of epoxy curing kinetics, resin viscosity, and polyurea-type, enabling mechanical and thermal behaviors to be aptly modified. Thirteen thin two-wythe (2.5-in per wythe) concrete beams were quasi-statically tested under 4-point loading; twelve HMC specimens were tested for thermal conductivity and resistivity (R-Value); and nine concrete panels were impact-tested, engendering enhanced mechanical and thermal behavior relative to conventional fiber-reinforced composites (FRP) and also to current industry-standard expanded polystyrene (EPS) and extruded polystyrene (XPS) insulation. Test results indicate that panels integrated with HMC designed with a lower-viscosity resin ( = 696 cps) and an epoxy curing time of 0.5 hours, where the epoxy network reacts with an aliphatic polyurea to elicit excellent dual thermal-mechanical performance. In this scenario, energy absorption, and R-value, using a heat flow meter apparatus, were calculated as 7.9 kJ and 4.71 hr∙ft2∙°F/(Btu∙in) respectively. Although thermal resistance (R-value) in counterpart XPS standard insulation systems was found to reach R-4.76 hr∙ft2∙°F/(Btu∙in), strength, energy absorption, and ductility were limited. Furthermore, composite beam action, or the shear transfer mechanism, at service and ultimate conditions in the highest-performing sample was calculated using stiffness and strength methods that elicited 22% and 337% respectively, deducing that HMC is an affordable dual-purpose insulation alternative in the multi-wythe construction of large precast tilt-up walls. A finite element model was developed to simulate PCSPs with HMC intermediate layer materials. indicating enormous potential of HMC as a dual thermal-mechanical system in tilt-up wall constructions.
Degree
thesis:*- Level thesis:degree_level
- Thesis
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Avalos, Hector R Orozco
- Contributors dc:contributor
-
- Thomas L Attard
- Cristopher Waldron
- Vinoy Thomas
Subjects
dc:subject × 7Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.library.uab.edu/etd-collection/2635