University of Alabama Birmingham
The impact of fine sensor spacing on complex tissue impedance spectra measurements in rabbit ventricular epicardium
Abstract
dc:description.abstractOur research group recently developed an instrumentation and signal processing approach that overcomes many of the obstacles associated with using small sensors to complete complex composite impedance (uCI) measurements, whose amplitude and phase depend upon the tissue's resistive and capacitive properties. The goal of this study was to test the feasibility of using smaller electrodes with finer separations than sizes traditionally employed in cardiac electrophysiologic studies with whole hearts to resolve uCI spectra in terms of magnitude (|uCI|) and phase (
Degree
thesis:*- Level thesis:degree_level
- Thesis
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Waits, Charlotte Mae Kent
- Contributors dc:contributor
-
- Andrew E Pollard
- Vladimir G Fast
- Jian Huang
- Jack M Rogers
- Diane C Tucker
Subjects
dc:subject × 5Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.library.uab.edu/etd-collection/3237