Measurements of heat capacity and heat transfer coefficient of water-oxygen mixtures at near critical conditions
Abstract
dc:descriptionThe constant-pressure heat capacity, Cp, and local forced convection heat transfer coefficient, h, for water-oxygen mixtures flowing inside horizontal smooth tubes were obtained experimentally. Data were obtained for pressures of 24 to 26 MPa; flow rates 0.636 to 1.27 l/min, average heat fluxes 34 to 160 kW/m², mass velocities 351 to 701 kg/m²s and temperatures from 330 to 430 °C. Oxygen flow was 2 to 8 weight percentage of the total mixture flow. For a given flow and heat supplied to the mixture, Cp is determined from the bulk temperature in a heated tube. The heat transfer coefficient, h is determined from the difference in bulk and wall temperatures. The temperature at which the maximum heat capacity occurs (Tpc) is lower for water-oxygen mixtures than for pure water. Another effect of oxygen addition is a reduction in magnitude of the maximum Cp and h. The enhancement near the critical point appears to be less at high heat flux.
Degree
thesis:*- Name thesis:degree_name
- Master of Applied Science - MASc
- Level thesis:degree_level
- master's
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Grantor dc:publisher
- University of British Columbia
- Year dc:date
- 2001
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Boskovic, Sanja
Rights
dc:rights- Statement dc:rights
-
- For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/2429/12034