University of British Columbia
Capillary electrophoresis-mass spectrometry and complementary approaches for semi-quantitative analysis of samples with complex matrices
Abstract
dc:descriptionCapillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) combines the superior separation efficiency of CE with the detection capability of MS to provide information-rich data on samples with complex matrices. CE-ESI-MS is applied to a range of complex mixtures to semi-quantify unknown components and find patterns among groups of samples. The first part of this thesis tells how the industrial generation of oil sands process-affected waters (OSPW) poses an environmental threat, and a review is given on the state-of-the-art of analytical chemistry in the semi-quantification of toxic naphthenic acid fraction compounds (NAFC) in OSPW. The chapter ends with a technical description of the CE-ESI-MS system which was utilized. CE-ESI-MS was demonstrated to produce effective analyses of a well-known complex mixture: human urine. CE-ESI-MS was used to quantify and “fingerprint” components in human urine via targeted and untargeted analyses of the sub-5 kDa urine metabolome of patients with prostate and/or bladder cancer. For targeted analysis, endogenous levels of sarcosine and 5 other metabolites were quantified in four patients and in a pooled healthy urine sample. An untargeted analysis of patient urine was also performed identifying over 400 distinct molecular features per patient. Next, a CE-ESI-MS method was developed for the analysis of a relatively unknown complex mixture: NAFCs in OSPW. A standard mixture of amine-derivatized naphthenic acids was analyzed in under 15 min, detecting NAFCs between m/z 250 and 800. Derivatization of NAFCs consisted of two-step amidation reactions mediated by 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) and N-hydroxysuccinimide in three different solvents. The optimum BGE composition was determined to be 30% (V/V) methanol in water and 2% (V/V) formic acid. The optimized CE-ESI-MS method was then used to find patterns in NAFCs across porewater samples impacted by oil sands waste. CE-ESI-MS, Orbitrap MS, and a standard GC-FID method were used to characterize porewater samples. Differences in measured amounts of total petroleum hydrocarbon by GC-FID and NAFC by HRMS indicate that the two methods provide complementary information about dissolved organic species in water leachate samples. CE-ESI-MS also provides complementary information and is a feasible and practical option for source evaluation of NAFCs in water.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy - PhD
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Chemistry
- Grantor dc:publisher
- University of British Columbia
- Year dc:date
- 2018
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- MacLennan, Matthew S.
Rights
dc:rights- Statement dc:rights
-
- Attribution-NonCommercial-NoDerivatives 4.0 International
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/2429/67116