As seismic design in Canada continues to evolve, many buildings designed to previous building code editions are left to their own devices, creating a vulnerability in communities exposed to large earthquakes. This thesis will examine the preparedness of communities in the lower mainland of British Columbia in the event of a M9 megathrust earthquake. It originates from the Cascadia Subduction Zone, a seismic source off the west coast of Canada and the United States. The focus of this thesis will be on the seismic performance of tall, pre-1980s, reinforced concrete shear wall buildings, which represent a large proportion of Vancouver’s tall buildings. A nonlinear dynamic analysis of an archetype building fitting the mentioned criteria was carried out using shell elements in LS-Dyna. Furthermore, using the FEMA P-2018 rating system, a rapid screening tool that assigns a rating to indicate relative collapse risk for each building considered, a general picture of the risk these building pose to the community could be formed. In recognition that collapse safety is not enough to create a more resilient community, as part of this study, a recently developed framework called TREADS (Tool for Recovery Estimation and Downtime Simulation) is used to describe the performance of the building by following resilience-based performance measures. Results for the nonlinear assessment showed that the archetype building has a large shear capacity due to the large number of walls. However, it is very brittle, and fails abruptly at a low drift ratio. Nevertheless, the FEMA P-2018 showed that this case study building has a rating indicating a relatively low seismic risk. By contrast, the loss and downtime assessment of the building showed that performance would fall short of the target recovery state of shelter-in-place after a 475yr return period earthquake and the target downtime to functional recovery of 4 months. Since the analysis using FEMA P-2018 suggests that the archetype building would perform better relative to other similar buildings, detailed analyses are recommended for any buildings of this type.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Civil Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Si, Jennifer
Contributors dc:contributor
  • Molina Hutt, Carlos

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/84175

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Si, Jennifer. Evaluating the functional recovery performance of a 1970s non-ductile reinforced concrete shear wall building. master's thesis, University of British Columbia, 2023. http://hdl.handle.net/2429/84175