Back to search

UCL (University College London)

Optimising MRI Quantitative Susceptibility Mapping Techniques for Clinical Translation and Accelerated Structural and Functional Research Applications

Abstract

dc:description.abstract

Quantitative susceptibility mapping (QSM) is a magnetic resonance imaging (MRI) technique that utilises the phase of the complex MRI signal and a physics-based reconstruction pipeline to estimate the underlying tissue susceptibility distribution. QSM provides information on tissue composition such as iron content affected in several neurodegenerative diseases. The gold-standard sequence for acquiring data for QSM is a 3D gradient echo (GRE) sequence, with a whole-brain acquisition time of approximately 5 minutes. Echo planar imaging (EPI) sequences can acquire whole-brain volumes in a few seconds, allowing both structural and functional neuroimaging. I present work on translating QSM into clinical practice through investigating the effects of oblique slice acquisition, developing a robust method to correct for tilted slices or volumes. I also developed and optimised a robust QSM acquisition protocol and QSM reconstruction pipeline for neuroradiological imaging of patients with movement disorders; neuroradiologist scores based on image quality demonstrated their preference for iterative Tikhonov and Auto non-linear dipole inversion (NDI) susceptibility calculation methods over total variation-based regularised methods. I optimised a QSM reconstruction pipeline for investigations into tissue composition changes in patients with temporal lobe epilepsy (TLE), to find susceptibility and R2* differences in TLE patients compared to healthy controls, affecting the hippocampus, amygdala, thalamus and basal ganglia. A major portion of my research was to optimise the QSM acquisition and reconstruction pipeline for a multi-echo 2D EPI sequence for rapid (< 4 s repetition time) structural and functional QSM. This included: investigating the use of simultaneous multi-slice (SMS) acceleration which was found to provide accurate and rapid EPI-QSM; comparing single-echo and multi-echo EPI acquisitions for QSM; developing methods to reduce geometric distortion inherent to EPI sequences; and reducing artefacts in reconstructed susceptibility maps through optimising the QSM pipeline for multi-echo 2D-EPI. I applied the results of these investigations to present optimised structural QSM, preliminary functional QSM and functional MRI (fMRI) results from a 1.3 mm isotropic resolution multi-echo EPI sequence with 3-fold SMS and 4-fold GRAPPA acceleration.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kiersnowski, Oliver C
Contributors dc:contributor
  • Shmueli, Karin
  • Thornton, John S

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10183385/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Kiersnowski, Oliver C. Optimising MRI Quantitative Susceptibility Mapping Techniques for Clinical Translation and Accelerated Structural and Functional Research Applications. Doctoral thesis, UCL (University College London), 2023. https://discovery.ucl.ac.uk/id/eprint/10183385/