UCL (University College London)
Optimising MRI Quantitative Susceptibility Mapping Techniques for Clinical Translation and Accelerated Structural and Functional Research Applications
Abstract
dc:description.abstractQuantitative susceptibility mapping (QSM) is a magnetic resonance imaging (MRI) technique that utilises the phase of the complex MRI signal and a physics-based reconstruction pipeline to estimate the underlying tissue susceptibility distribution. QSM provides information on tissue composition such as iron content affected in several neurodegenerative diseases. The gold-standard sequence for acquiring data for QSM is a 3D gradient echo (GRE) sequence, with a whole-brain acquisition time of approximately 5 minutes. Echo planar imaging (EPI) sequences can acquire whole-brain volumes in a few seconds, allowing both structural and functional neuroimaging. I present work on translating QSM into clinical practice through investigating the effects of oblique slice acquisition, developing a robust method to correct for tilted slices or volumes. I also developed and optimised a robust QSM acquisition protocol and QSM reconstruction pipeline for neuroradiological imaging of patients with movement disorders; neuroradiologist scores based on image quality demonstrated their preference for iterative Tikhonov and Auto non-linear dipole inversion (NDI) susceptibility calculation methods over total variation-based regularised methods. I optimised a QSM reconstruction pipeline for investigations into tissue composition changes in patients with temporal lobe epilepsy (TLE), to find susceptibility and R2* differences in TLE patients compared to healthy controls, affecting the hippocampus, amygdala, thalamus and basal ganglia. A major portion of my research was to optimise the QSM acquisition and reconstruction pipeline for a multi-echo 2D EPI sequence for rapid (< 4 s repetition time) structural and functional QSM. This included: investigating the use of simultaneous multi-slice (SMS) acceleration which was found to provide accurate and rapid EPI-QSM; comparing single-echo and multi-echo EPI acquisitions for QSM; developing methods to reduce geometric distortion inherent to EPI sequences; and reducing artefacts in reconstructed susceptibility maps through optimising the QSM pipeline for multi-echo 2D-EPI. I applied the results of these investigations to present optimised structural QSM, preliminary functional QSM and functional MRI (fMRI) results from a 1.3 mm isotropic resolution multi-echo EPI sequence with 3-fold SMS and 4-fold GRAPPA acceleration.
Degree
thesis:*- Level dc:type.qualificationlevel
- Doctoral
- Grantor dc:publisher.institution
- UCL (University College London)
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kiersnowski, Oliver C
- Contributors dc:contributor
-
- Shmueli, Karin
- Thornton, John S
Rights
- Language dc:language
- en, eng
Identifiers
dc:identifier.*- Repository record dc:identifier.uri
- https://discovery.ucl.ac.uk/id/eprint/10183385/