Back to search

UCL (University College London)

Partial volume correction of 99mTc oncology SPECT imaging via case specific resolution estimation

Abstract

dc:description.abstract

This project aimed to develop a practical method to compensate for the detrimental effect of limited spatial resolution in Tc-99m nuclear medicine oncology imaging. Correction for limited resolution is currently not routinely applied in clinical practice, limiting quantitative accuracy. Literature review identified existing correction strategies, then assessed based on oncology-specific criteria. This found no existing method ideal for oncology. Specifically, many existing correction methods assume that resolution is invariant, which is not a valid assumption for SPECT imaging. Two methods were selected for further investigation. Key factors affecting SPECT resolution were investigated by simulating SPECT acquisition and reconstruction for simple digital phantoms. Practical experiments demonstrated that assuming invariant resolution could introduce inaccuracies in correcting for the effects of limited resolution. Case-specific resolution was estimated using the perturbation method, and subsequently incorporated into correction algorithms. This was tested using a range of datasets including simple digital phantoms and computerised anthropomorphic models - with images generated by analytical simulation. Quantitative accuracy improved for correction algorithms incorporating case-specific resolution. Realistic test datasets developed based on clinical data were used with Monte Carlo software to simulate image acquisition. Two correction algorithms, used with perturbation, were compared with a conventional correction method. Results demonstrated that the Single Target Correction (STC) method with perturbation performed as well as the conventional, Recovery Coefficient (RC), method for regional quantification, with the added advantages of producing an image and capturing heterogeneity within the object of interest. Further work in this area, including assessment of other factors which contribute to quantitative accuracy of quantitative SPECT imaging is required. The work in this thesis could potentially contribute to the practical implementation of correction for the detrimental effect of limited spatial resolution, moving towards images which can more accurately aid the diagnosis, monitoring and treatment of oncology patients.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Livingstone Gillen, Rebecca
Contributors dc:contributor
  • McQuaid, Sarah
  • Thielemans, Kris
  • Hutton, Brian
  • Denis-Bacelar, Ana

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10213593/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Livingstone Gillen, Rebecca. Partial volume correction of 99mTc oncology SPECT imaging via case specific resolution estimation. Doctoral thesis, UCL (University College London), 2025. https://discovery.ucl.ac.uk/id/eprint/10213593/