University of Minnesota
Thermal performance of solar-assisted thermo-active foundation with a double u-loop heat exchanger in a cold climate
Abstract
dc:description.abstractGround source heat pumps are a renewable energy option to reduce greenhouse gas emissions from building's space heating and cooling. Placing the heat exchanger within the structures of new homes creates a cost-effective “thermo-active foundation.” This research aims to explore the potential of “thermo-active foundations” with a double u-loop ground heat exchanger enhanced with a solar thermal collector and latent thermal energy storage. This study determines the appropriately sized solar collector needed at three locations to maintain the ground’s thermal balance, then the system was enhanced using phase change material as a thermal energy storage component. Results show the sized collectors without the thermal energy storage system, the overall coefficient of performance was 3.86, 3.79, and 3.98 for International Falls, Duluth, and Winona respectively. The enhanced results show that when incorporating phase change material, the coefficient of performance is 3.75, 3.82, and 3.86 for International Falls, Duluth, and Winona, respectively.
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Gruenes, Jordan
Subjects
dc:subject × 12- cold climate
- double u-loop
- heat exhangers
- solar-assisted
- thermal energy storage
- thermo-active foundation
- Plan As (thesis-based master's degrees)
- Master of Science
- Master of Science in Mechanical Engineering
- Department of Mechanical and Industrial Engineering
- Swenson College of Science and Engineering
- University of Minnesota Duluth
Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Citation
- Gruenes, Jordan. (2024). Thermal performance of solar-assisted thermo-active foundation with a double u-loop heat exchanger in a cold climate. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/269532.