Back to search

University of South Florida

Sorption of Benzene, Tolueneand Ethylbenzeneby Plasticized PEMA and PEMA/PMMA Sensing Films Using aQuartz Crystal Microbalance (QCM) at 298.15K

Abstract

dc:description

Detection of volatile organic compounds (VOC’s) in the environment is important for human health and wellness. Long term exposure of certain VOC’s like benzene, toluene, ethylbenzene and xylene (BTEX) has a severe effect on human health. There are techniques such as gas chromatography, photo ionization, and mass spectroscopy that are time consuming, require gas sampling and are ineffective in real time sensing in air. Acoustic wave devices such as surface acoustic wave (SAW) devices can be used for sensing BTEX compounds in both vapor and liquid phase. The quartz crystal microbalance (QCM) is a low-frequency acoustic wave device, which can be used to characterize polymer film sensing quickly and easily by studying the sorption properties of BTEX compounds in them. In this work, thin films (~ 0.5 microns) of polymer/plasticizer blends are spin-coated on a 5MHz QCM for the detection of VOC’s. A polymer/plasticizer combination of poly (ethyl methacrylate) (PEMA) and a copolymer of poly (ethyl methacrylate) and poly (methyl methacrylate) (PEMA/PMMA) with di n-butyl phthalate (DBP), di-n-butyl sebacate (DBS) and n-butyl stearate (BS) are used for the detection of benzene, toluene and ethylbenzene in vapor phase. The working apparatus consists of a stream of solvent vapor diluted with nitrogen to an arbitrary concentration passing over the QCM oscillated to its resonant frequency. The sorption data are reported at 298.15 K in terms of activity as a function of weight fraction curves and are interpreted with the Flory-Huggins ternary model. The addition of plasticizer modifies the free volume properties of the polymer, thereby increasing diffusion and sensitivity of BTEX vapors. The plasticizer composition is tailored to 17.5%, for maximum sorption with minimal viscoelastic effects. The sorption and sensitivity of BTEX are interpreted and studied in terms of plasticizer type and concentration.

Degree

thesis:*
Name thesis:degree_name
MS in Chemical Engineering (M.S.C.H.)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Chemical Engineering
Grantor
University of South Florida
Year dc:date
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Adapa, Deekshitha
Contributors dc:contributor
  • Venkat Bhethanabotla, Ph.D.
  • Scott Campbell, Ph.D.
  • John Kuhn,Ph.D.

Subjects

dc:subject × 5

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.usf.edu/etd/7720

Chain of custody

source
Harvested from
University of South Florida
Base URL
digitalcommons.usf.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Adapa, Deekshitha. Sorption of Benzene, Tolueneand Ethylbenzeneby Plasticized PEMA and PEMA/PMMA Sensing Films Using aQuartz Crystal Microbalance (QCM) at 298.15K. Thesis thesis, University of South Florida, 2019. https://digitalcommons.usf.edu/etd/7720