Back to search

Hosted by Utah State University Libraries

Comparative Studies on Oxygen Mass Transfer for the Design and Development of a Single-Use Fermentor

Abstract

dc:description.abstract

Accurate experimental oxygen mass transfer coefficient, a measure of how quickly oxygen travels from a gas bubble to the bulk liquid, is important for comparing performance and for evaluating the oxygen transfer capability of a fermentor. Delays in probe response and changing gas volumes upon start-up of gassing affect the accuracy of oxygen transfer measurements. To mitigate these inaccuracies, a standard correction procedure for oxygen mass transfer data was established for highly oxygenated, well-mixed fermentation systems. Probe response time correction was generated by applying a second-order response model to dissolved oxygen probes and shown to be effective within 4%. By using a derived model for transient volume rise, the effect of changing gas volume at start-up was shown to cause very minimal error (1-2%) in kLa. The unsteady-state method of kLa determination was used to compare design aspects of a hypothetical fermentor, including gas sparging devices and locations, baffle geometries and quantities, and impeller configurations. It was shown that locating the sparging device in the center of the tank, directly below the drive shaft and bottom impeller, is optimal for oxygen mass transfer. Sparger type was shown to have little effect on oxygen mass transfer values, although an open-pipe sparger was shown to provide slightly more oxygen mass transfer than a ring sparger. The use of rounded baffles in place of traditional rectangular baffles resulted in a 67-80% decrease in oxygen mass transfer coefficient. A comparison of three and four traditional baffles showed that three baffles produced a higher oxygen mass transfer than four. Correlation of baffle ratio and oxygen mass transfer coefficient indicated that the optimum baffle ratio is approximately one. Radial impellers were observed to provide better mixing, and thus higher oxygen mass transfer coefficients than axial impellers. In seven of ten comparisons, an impeller quantity ratio of 1.33 instead of 1.00 provided significant improvement in kLa. Additionally, only two of ten comparisons showed a difference between traditional Rushton turbine impellers and Smith turbine impellers, indicating that the difference in oxygen mass transfer capability of the two is negligible.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Biological Engineering
Grantor dc:publisher
Hosted by Utah State University Libraries

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sorenson, Kristan L.
Contributors dc:contributor
  • Timothy Taylor
  • Ronald Sims
  • Heng Ban

Subjects

dc:subject × 7

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Utah State University
Base URL
digitalcommons.usu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Sorenson, Kristan L.. Comparative Studies on Oxygen Mass Transfer for the Design and Development of a Single-Use Fermentor. Thesis thesis, Hosted by Utah State University Libraries, https://digitalcommons.usu.edu/etd/738