Hosted by Utah State University Libraries
Simulation of Counterintuitive Pressure Drop in a Parallel Flow Design for a Specimen Basket for Use in the Advanced Test Reactor
Abstract
dc:description.abstractTo continue improving nuclear energy, new materials must be tested in testing reactors such as the Advanced Test Reactor (ATR) at Idaho National Laboratory. A new test cap section allowed coolant to contact specimens tested in the ATR. A parallel channel test cap section should reduce the pressure drop across this section compared to a single channel. A fluid experiment conducted by Idaho State University showed the pressure drop was actually greater. A Computation Fluid Dynamics simulation using STAR-CCM+ was conducted of the fluid experiment to explain the abnormal pressure drop. The simulation provided evidence of ow through the test section required for a corrosion test and supported the results of the fluid experiment. Some pressure drop was caused by nozzle-like design and sudden expansion and contraction. Chaotic mixing produced some pressure drop. Flow disturbance related to flow rate caused a pressure drop at high flow rates when the fluid separated into each channel. The anomalous pressure drop was caused by the design of the test cap section.
Degree
thesis:*- Name thesis:degree_name
- Master of Science (MS)
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Mechanical and Aerospace Engineering
- Grantor dc:publisher
- Hosted by Utah State University Libraries
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Zabriskie, Adam X.
- Contributors dc:contributor
-
- Heng Ban
- Robert Spall
- Leijun Li