Hosted by Utah State University Libraries
Venturi Meter Performance When Installed on the Branch of a Tee Junction with Converging Run Flow
Abstract
dc:description.abstractVenturi flow meters are often installed downstream of disturbances such as a tee junction, valve, or elbow. In such a case, a laboratory calibration may be needed to measure the Venturi meter’s performance under said limitations so that accurate metering is achieved. However, in some cases, laboratory calibration may not be possible.The purpose of this research was to investigate Computational Fluid Dynamics (CFD) ability to simulate a Venturi meter installed on the branch of a tee junction with converging run flow. This study used CFD to compare against laboratory results to illustrate CFD’s capability as a calibration method. The results of this study were used to develop a procedure to adjust a Venturi meter’s discharge coefficient for a Venturi meter that will be, or already is, installed on the branch of a tee junction with converging run flow.
Degree
thesis:*- Name thesis:degree_name
- Master of Science (MS)
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Civil and Environmental Engineering
- Grantor dc:publisher
- Hosted by Utah State University Libraries
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Naulu, E. Elliot
- Contributors dc:contributor
-
- Michael C. Johnson
- Zachary B. Sharp
- Marv Halling