Back to search

University of Victoria (Canada)

Fixed-point hardware design for CPWC image reconstruction

Abstract

dc:description.abstract

Coherent plane-wave compounding (CPWC) ultrasonography is an important imaging modality that allows for very high frame rates. During CPWC image reconstruction, computationally expensive delay-and-sum beamforming can be replaced by faster Fourier-domain remapping. The thesis deals with the MATLAB and hardware implementation of one of the recently proposed Fourier-domain CPWC reconstruction methods, namely, plane-wave (PW) Stolt's migration algorithm. We first present the floating- and fixed-point implementations of the said migration algorithm in MATLAB, and then perform quantitative evaluation of the reconstruction results, showing that it is feasible to obtain high-quality compounded images using hardware-oriented scaled fixed-point calculations, as opposed to more expensive software-oriented floating-point arithmetic. We also generate Xilinx FPGA-based implementations of both floating- and fixed-point MATLAB-based algorithms, using a high-level synthesis (HLS) design flow that collaboratively employs MATLAB Coder and Vivado HLS tool. MATLAB Coder can automatically convert a MATLAB code into a C program, while Vivado HLS can convert the resulting C program into a synthesizable Verilog/VHDL description. Results show that our fixed-point FPGA implementation is more resource and power efficient and can also operate at a higher clock frequency compared to its floating-point counterpart.

Degree

thesis:*
Level thesis:degree_level
Master of Applied Science M.A.Sc.
Department thesis:degree_department
Department of Electrical and Computer Engineering
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Shi, Ji
Advisor dc:contributor.supervisor
  • Rakhmatov, Daler N.

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Available to the World Wide Web
Language dc:language.iso
en, English

Identifiers

dc:identifier.*
Dc Identifier Citation
J. Shi and D. Rakhmatov,“Fixed-point CPWC ultrasound image reconstruction,”in 2019 IEEE International Ultrasonics Symposium (IUS). IEEE, 2019, pp. 1282–1285.

Chain of custody

source
Harvested from
University of Victoria (Canada)
Base URL
dspace.library.uvic.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Shi, Ji. Fixed-point hardware design for CPWC image reconstruction. Master of Applied Science M.A.Sc. thesis, 2020. http://hdl.handle.net/1828/11658