Back to search

Virginia Commonwealth University

Effect of Clear Aligner Attachment Size on Extrusion of Maxillary Lateral Incisors: A Randomized Controlled Trial

Abstract

dc:description.abstract

<p><strong>Objective</strong>: Predictable maxillary lateral incisor extrusion with clear aligners remains a clinical challenge. Clinicians often select attachment design based on anecdotal experience rather than prospective evidence. This multicenter randomized controlled trial compared the clinical efficacy of Invisalign optimized extrusion attachments against three sizes of horizontal gingivally-beveled attachments (1×1×3 mm, 1×1×4 mm, 1×1×5 mm) and evaluated patient esthetic perceptions of each.</p> <p><strong>Methods</strong>: Patients requiring at least 0.5 mm of maxillary lateral incisor extrusion were recruited across four clinical sites. Targeted incisors were randomized into four groups: Optimized (O), or Horizontal 3mm (H3), 4mm (H4), and 5mm (H5). Digital models (Pretreatment, Predicted, and Posttreatment) were superimposed using Geomagic software to quantify extrusion accuracy. Patient esthetic satisfaction was captured via a REDCap survey using a 5-point Likert scale.</p> <p><strong>Results</strong>: Thirty-one teeth from 18 patients were analyzed. Achieved extrusion was significantly lower than predicted, with a median of 70% of planned movement. Optimized attachments produced significantly greater extrusion than horizontal gingivally beveled attachments (92% vs. 52%; p=0.0108), while no significant differences were observed among horizontal attachment sizes. Survey results indicated high esthetic satisfaction across all cohorts. No statistically significant differences in esthetic perception were observed between attachment designs.</p> <p><strong>Conclusion</strong>: Optimized extrusion attachments significantly outperformed horizontal gingivally beveled attachments, achieving greater extrusion efficiency without compromising esthetics. Increasing horizontal attachment size did not improve extrusion outcomes. Optimized attachments are therefore recommended for maxillary lateral incisor extrusion with Invisalign.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science in Dentistry
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Dentistry
Year dc:date.available
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Catalano, Alexis M
Contributors dc:contributor
  • Christina Philips
  • Steven Lindauer
  • Bhavna Shroff
  • Caroline Carrico
  • Parthasarthy Madurantakam

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • © The Author

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Virginia Commonwealth University
Base URL
scholarscompass.vcu.edu/do/oai/
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation