Virginia Tech
The Chondroid Conundrum: Transpharyngeal Removal of Guttural Pouch Chondroids in Horses
Abstract
dc:description.abstractRemoval of chondroids from the guttural pouches (GP) of affected horses is essential to prevent asymptomatic transmission of Strangles (Streptococcus equi subsp equi). Current chondroid removal via endoscopic basket or percutaneous surgery has limitations, including time, cost and complications. Dorsal pharyngeal recess (DPR) fenestration of the GP using transendoscopic laser is minimally invasive, but has not been optimized for removal of GP chondroids. Our objective was to determine if a 3D-printed instrument improved lavage efficacy for chondroid removal from a dorsal pharyngeal recess (DPR) fenestration, and to compare instrument placement directly through the DPR fenestration vs. through the SPO. We hypothesized that: 1) use of a 3D-printed instrument would recover more prostheses, reduce lavage time, and incur less soft tissue damage than lavage alone; and 2) that 3D-printed instrument placement through the DPR would recover more prostheses, reduce lavage time, and incur in less soft tissue damage than placement through the salpingopharyngeal ostium (SPO) in equine cadaveric heads. Procedures to remove 50 plastic 12 mm bead prostheses from the GP were randomized for 10 repeats: DPR+3D: 3D-printed instrument via DPR; DPR-3D: lavage via DPR; SPO+3D: 3D-printed instrument via SPO; SPO-3D: lavage via SPO. Lavage was administered in 2-minute cycles via 3D-printed instrument or tubing control. Bead recovery and rate to remove ≥96% or 3 consecutive no-yield cycles was recorded. Soft tissue damage was graded via endoscopy. Data were compared by GEE model and Fisher's exact test (p < 0.05). Median laser surgery time was 1225 seconds (range 563-2400 seconds). 3D-printed instrument chondroid removal procedures recovered significantly more beads (median 48 beads; range 0-49) and were significantly faster (median 24 beads/cycle; range 12-50) than lavage alone (median 6 beads/cycle; range 0-29 and 0.66 beads/cycle, range 0-49). There was no difference when the 3D-printed instrument was used through the DPR fenestration or SPO. Superficial mucosal damage occurred after 43.4% of fenestrations. Post-procedure, there was no difference in soft tissue damage between procedures (30.4% of heads). Use of the custom 3D-printed instrument efficiently removed GP chondroids through a DPR fenestration when used either through the fenestration or via the SPO. It may be a viable treatment alternative to current techniques and warrants testing in live horses.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Biomedical and Veterinary Sciences
- Department dc:contributor.department
- Biomedical and Veterinary Sciences
- Grantor dc:publisher
- Virginia Tech
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Cardona, Guillermo Andres
- Chair dc:contributor.committeechair
-
- Bogers, Sophie Helen
- Committee members dc:contributor.committeemember
-
- Byron, Christopher R.
- Dahlgren, Linda A.
- McKenzie, Harold C.
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- In Copyright
- Licence dc:rights.uri
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Other
- vt_gsexam:38288