Back to search

University of Leeds

Next generation of atraumatic laparoscopic instruments through analysis of the instrument-tissue interface

Abstract

dc:description.abstract

Mechanically induced (or iatrogenic) bowel injury from the use of laparoscopic instruments can result in devastating effects on patient outcomes both during and after surgery. The aim of this work was to investigate exactly how colonic tissue behaves both mechanically and structurally when it is subjected to a mechanical load. Analysis of force application in laparoscopic surgery is critical to understanding the nature of the instrument-tissue interaction. The development of a novel method of both histological analysis and mechanical analysis (by which the tool-tissue interaction can be characterised) has evolved through this thesis. Mechanical and histological analysis was undertaken to quantify the instrument-tissue interaction in laparoscopic surgery. This was done in both ex vivo and in vivo experiments, using an indentation method and laparoscopic instrument respectively, in porcine tissue. Mechanical stress was applied to the colon by indentation applied using the Modular Universal Surface Tester (MUST) (FalexTM Tribology USA) in ex vivo experiments to mechanically characterise the response of tissue to mechanical loading. Histological analysis was performed to examine the architecture of the tissue after loading. In vivo analysis of colon grasping was then performed to characterise grasper damage both mechanically and histologically. A mechanical measure of energy input into the tissue has been linked to consistent histological damage, above a 50 N grasping force and a loading input of 300 N.s This work has successfully identified specific loading conditions that result in tissue injury and is the first to make a link between the mechanical analyses of tissue manipulation with change to the architecture of the tissue.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Leeds
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Barrie, Jenifer
Advisors dc:contributor.advisor
  • Neville, Anne
  • Calmer, Peter R.
  • Jayne, David G.
  • Pavitt, Sue

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Identifier
uk.bl.ethos.703364

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Barrie, Jenifer. Next generation of atraumatic laparoscopic instruments through analysis of the instrument-tissue interface. doctoral thesis, University of Leeds, 2017.