Back to search

West Virginia University

Evaluation of Concavity Compression Mechanism as a Possible Predictor of Shoulder Muscle Fatigue

Abstract

dc:description.abstract

The overall impact of shoulder musculoskeletal disorders (MSDs) in the workplace is enormous in terms of worker’s health, and corporate economics. To recognize the risk factors for shoulder MSDs, previous studies have used questionnaires, clinical examinations, direct measurements, observational, and modeling methods. While most of the existing studies substantiate that the shoulder strain (e.g. pain/discomfort, muscle force or activity, joint loading, etc.) is affected by the stress (e.g. force, posture, repetition), the underlying mechanism that explains how the shoulder joint is strained when subjected to different levels of stress is not well understood. In this study, concavity compression, a stabilizing mechanism of the shoulder joint was evaluated as a possible underlying mechanism that can explain the stress-strain relationship for the shoulder joint during dynamic physical exertions. The study was completed in three steps. In the first step, a shoulder strain index based on the concept of concavity compression mechanism was developed. Eight male participants performed thirty different material handling tasks in various work positions using a weight of 2 lb. A biomechanical model of the shoulder complex was used to estimate the resultant reaction forces acting on the right shoulder joint during these tasks. Based on the concept of concavity compression, the reaction forces were used to formulate the strain index. Higher value of the strain index signified higher stabilizing demand and therefore higher shoulder strain. Based on the strain index values, the tasks were categorized into low, medium and high strain tasks. In the second step, a global muscle fatigue index that considers the anatomical characterization of the muscles and their physiological and biomechanical contributions during a physical exertion was developed. Eight participants performed fatiguing exertions under static and dynamic conditions using two different weights of 2 lb and 6 lb. The activity of eight shoulder muscles – supraspinatous, infraspinatous, teres major, middle deltoid, anterior deltoid, posterior deltoid, biceps, and triceps of the right shoulder joint were recorded using surface electromyography (SEMG). Muscle fatigue was evaluated by measuring percent change in global fatigue index between first and last repetitions. Results indicated that the global fatigue index was sensitive to the fatigue related neuromuscular changes and was able to accurately predict the shoulder joint fatigue. In the third step, the appropriateness of concavity compression mechanism in estimating shoulder strain was evaluated by testing a central hypothesis: “tasks that put higher stabilizing demand on the shoulder muscles (estimated using strain index) would result in higher fatigue (estimated using fatigue index)”. Ten male participants performed repetitive exertions using the previously identified high, medium, and low strain tasks using three different weight conditions (2, 4, and 6 lb). The SEMG data were recorded from the above-mentioned shoulder muscles. The global muscle fatigue index was calculated for the first and last three repetitive exertions of each task to estimate development of fatigue. A two-factor randomized complete block design was used to test the relationship between the strain index and global fatigue index. Results showed that tasks having higher strain index values and force levels resulted in significantly (P< 0.001) higher percent change in global fatigue index. The highest percent change in the global fatigue index and the highest perceived exertion score was observed for the high strain task performed at 6 lb weight condition. Similarly, the lowest percent change in the GFI value and the lowest perceived exertion score was observed for the low strain task performed at 2 lb weight condition. Thus, the overall results of this study seem to indicate that the concavity compression mechanism can explain the stress-strain relationship for the shoulder joint during dynamic physical exertions. A shoulder strain index based on the concept of concavity compression mechanism can predict the stabilizing demand and thus the shoulder muscle fatigue during dynamic physical exertions. The strain index developed in this study could potentially have applications in the workplaces to identify the stressful exertions that may increase the risk of shoulder MSDs.

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Mechanical and Aerospace Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Chowdhury, Suman Kanti
Contributors dc:contributor
  • Ashish Nimbarte
  • Bhaskaran Gopalakrishnan
  • Hongwei Hsiao
  • Majid Jaridi
  • Xiaopeng Ning

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
West Virginia University
Base URL
researchrepository.wvu.edu/do/oai/
Last updated
2026-11-21
Source record
OAI-PMH GetRecord
related terms
citation

Chowdhury, Suman Kanti. Evaluation of Concavity Compression Mechanism as a Possible Predictor of Shoulder Muscle Fatigue. Dissertation thesis, https://doi.org/10.33915/etd.5364