331

Experimental Studies Of Electron Spin Dynamics In Semiconductors Using A Novel Radio Frequency Detection Technique

Guite, Chinkhanlun 06 1900 (has links) (PDF)
A novel experimental setup has been realized to measure weak magnetic moments which can be modulated at radio frequencies (~1–5 MHz). Using an optimized radio-frequency (RF) pickup coil and lock-in amplifier, an experimental sensitivity of 10 -15 Am2 corresponding to 10 -18 emu has been demonstrated with a one second time constant. The detection limit at room temperature is 9.3 10 -16 Am2/√Hz limited by Johnson noise of the coil. In order to demonstrate the sensitivity of this technique it was used to electrically detect the polarized spins in semiconductors in zero applied magnetic fields. For example in GaAs, the magnetic moment due to a small number (~ 7 x 108) of spin polarized electrons generated by polarization modulated optical radiation was detected. Spin polarization was generated by optical injection using circularly polarized light which is modulated rapidly using an electro-optic cell. The modulated spin polarization generates a weak time-varying magnetic field which is detected by the sensitive radio-frequency coil. Using a radio-frequency lock-in amplifier, clear signals were obtained for bulk GaAs and Ge samples from which an optical spin orientation efficiency of ~ 10–20% could be determined for Ge at 1342 nm excitation wavelength at 127 K. In the presence of a small external magnetic field, the signal decayed according to the Hanle Effect, from which a spin lifetime of 4.6 ± 1.0 ns for electrons in bulk Ge at 127 K was extracted. The spin dynamics in n-Ge was further explored and the temperature dependence of the spin lifetime was plotted for a temperature range of about 90 K to 180 K. The temperature dependence of the optical pumping efficiency was also measured though no quantitative conclusions could be derived. The signals observed for semi-insulating GaAs, n-GaAs, GaSb and CdTe which are direct gap semiconductors are much larger than expected (almost two orders of magnitude). An attempt was made to explain this unexpected behavior of these direct gap semiconductors using the spin hall effect.
332

Ultra-large sheet formation by 1D to 2D hierarchical self-assembly of a “rod–coil” graft copolymer with a polyphenylene backbone

Huang, Yinjuan, Yuan, Rui, Xu, Fugui, Mai, Yiyong, Feng, Xinliang, Yan, Deyue 17 July 2017 (has links)
This communication reports a unique ultra-large sheet formation through hierarchical self-assembly of a rod–coil graft copolymer containing a rigid polyphenylene backbone and flexible poly(ethylene oxide) (PEO) side chains. The hierarchical self-assembly process involved a distinctive morphological transition of 1D helical to 2D superstructures. The graft copolymer offers a new chance for the challenging bottom-up fabrication of ultra-large self-assembled nanosheets in solution, as well as a novel system for fundamental studies on 2D self-assembly of polymers.
333

Řízení orientace družice - laboratorní úloha / Orientation Control of Satellite - Laboratory Experiment

Neužil, Ondřej January 2018 (has links)
This diploma thesis is about the basics of satellite systems, about their sorting, usage and technologies. An important part is the description of the principles controlling and stabilization of the small experimental CubeSat type satellites. The main point is the proposition and construction of the laboratory model of the CubeSat type satellite that should simulate the chosen methods of controlling and stabilization in laboratory conditions. The thesis describes the construction of the electronic parts of the model, the controlling software of the satellite’s processor and user software for easy controlling by PC.
334

Výroba sendvičové závitové vložky objemovým tvářením / Bulk forming technology of sandwich coil insert

Šíma, Vojtěch January 2019 (has links)
The project elaborated in a frame of Master‘s degree branch M-STG focuses on the design of a technology of sandwich coil used for connecting the aircraft floor sandwich panels to the fuselage bulkheads. The product is made of a lightweight aluminium alloy AlMn1. Combined cold extrusion with upsetting of the flange was chosen as the most fitting technology due to the manufacturing requirements and production series size of 120 000 pieces per year. The component is manufactured from a block blank in three operations by a progressive forming machine TPM 8-A with a nominal force of 1000 kN from Šmeral Brno a.s. producer. Within the project, tools for the production of the part were designed and also technical calculations for individual operations and technical and economic evaluation of production were made. The price of the component is estimated to be at least CZK 7,33.
335

NÁVRH NDT METODY PRO HODNOCENÍ DRÁTKOBETONU / DESIGN OF NON-DESTRUCTIVE METHOD FOR TESTING OF STEEL FIBER REINFORCED CONCRETE

Komárková, Tereza January 2019 (has links)
The doctoral thesis deals with a non-destructive testing method (NDT) designed to evaluate the uniformity of distribution and determination of the concentration of steel fibres in steel fiber reinforced concrete (SFRC). At present, no non-destructive method is available in the field of diagnostics of building structures to assess the concentration and the homogeneity of SFRC. The Institute of Building Testing (SZK FAST BUT Brno) has several diagnostic devices, but their utility for the evaluation of selected parameters of SFRC has not proven during the research activity. This knowledge led to the design of a new measuring instrument in cooperation with the Institute of Theoretical and Experimental Electrical Engineering of the Faculty of Electrical Engineering and Communication (UTEE FEKT BUT in Brno) and the methodology for evaluation of these parameters. The proposed NDT method has been experimentally tested and verified for its utility for the evaluation of SFRC in building practice.
336

Třísítný vibrační třídič / Three-sided vibrating screen

Švrček, Jakub January 2020 (has links)
This diploma thesis deals with the design of an inclined three-sided vibrating screen, which is designed for sorting bulk aggregates. The aim of the diploma thesis is primarily to make a construction design with a specific comparison of various design solutions, considering the calculated operating parameters. In the construction design, is used not only the experience of the manufacturer of this type of machine, but also recommendations based on the manu-facturers of screens component. The design also includes a comparison of two types of flex-ible mounting, which is one of the basic structural units of the entire vibrating screen. The thesis is conceived from the basics, with emphasis on the simplicity and functionality of the device.
337

Magnetoterapeutický přístroj pro léčbu dětské mozkové obrny / Magnetotherapeutic device for Child Neurology

Walek, Petr January 2010 (has links)
Project Magnetotherapeutic device for Child Neurology in his forepart paies medical use of Pulsatile Magnetic Field. Summaries a therapeutic effects of field which is interacting with biotic issue and determines which of those effects are acceptable for treatment of Infantile Paralysis. Below it describes single Bio-Parametres of Pulsatile Magnetic Field and analyses reasons and effects of Infantile Paralysis. In second part is described a block diagram of magnetotherapeutic device for treatment of Infantile Paralysis. Described is principle of function of blocks. In third part is defined circuit solving of controlling, supervisory and generating part of magnetotherapeutic device. Function and wiring of components is described in detail. There is also created a Printed Circuit Board. Device is controlled by three microcontrollers, therefore there are described flowcharts and controlling programs for microcontrollers.
338

Software pro řízení zapalování a vstřikování spalovacích motorů / Engine Motormanagement Software

Huška, Lukáš January 2010 (has links)
This master thesis deals with ignition systems which are used in cars vehicles with gas engines and also with setting of the best moment of ignition of gasoline-air mixture in cylinders of engine. Ways of gas injection at diesel engines and their control systems are also described in this thesis. Next chapter deals with control unit and describes main actions which are necessary for today’s motor vehicles. As illustration is used example of succession of actions which are necessary for calculation and setting regular value of pre-ignition. At the end is shown animation, which can be used for practice lessons in a subject Automobile Electric and Electronic Systems as a example. It will simplify understanding of described activities which are all accomplished by central control unit. For purposes of laboratory lessons is in this thesis also discussed measuring of engine performance with changes of parameter of central control unit.
339

Vývoj bezdrátové bachorové sondy / Development of wireless rumen probe

Šídlová, Ludmila January 2011 (has links)
The aim was to study the possibilities of wireless transmission from the stomach of ruminants and to design and implement wireless ruminal probe. The first part deals with the internal wireless probe. The next section describes and evaluates available ruminal probe. There is given its own equipment design in the other chapters. The probe was designed for power management and for working with harvestable ambient power. The frequency of 125 kHz with bipolar coding was chosen for wireless data transmission. Two air coils are used on both sides as antennas. The proposed probe was designed and wireless data transmission was tested.
340

Měřicí systém impulzního proudového zdroje / Measurement system for pulsed current source

Myška, Radek January 2011 (has links)
This work deals with the description and analysis of suitable methods for measurement of non-periodical high-level current pulses. For pulsed current source design and development a suitable measurement system is required. In this work shunt resistor, Rogowski sensor and magneto-optic sensor are presented. The analysis of their properties is performed in order to design a suitable sensor for test current pulse measurement. A design of Rogowski coil sensor has been made. An experimental measurement of current pulses with short time relations has been performed. The suitability of the coil sensor for non-harmonic waveforms measurement has been evaluated on the basis of measurement results. In case of the magneto-optic sensor a concept utilizing an optical fiber has been proposed. The design of the sensor has been performed also. Individual parts of the sensor were verified. Experimental magneto-optic sensors have been built and their properties have been studied.