• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • 14
  • 13
  • 13
  • 13
  • 13
  • 12
  • 2
  • 2
  • 1
  • Tagged with
  • 95
  • 95
  • 41
  • 34
  • 25
  • 24
  • 22
  • 17
  • 16
  • 15
  • 14
  • 13
  • 13
  • 13
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Influência de três tratamentos de superfície para cerâmicas a base de zircônia na resistência adesiva e no comportamento à fadiga do material

Amaral, Marina [UNESP] 06 June 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-06-06. Added 1 bitstream(s) on 2015-06-18T12:46:53Z : No. of bitstreams: 1 000826190.pdf: 2371983 bytes, checksum: 1a6cae4c3630473d345c8d57f0a5e4ee (MD5) / O objetivo deste trabalho é avaliar o efeito de dois diferentes métodos de deposição de sílica na superfície de uma cerâmica a base de zircônia estabilizada por ítria na adesão a um cimento resinoso e no limite de fadiga do material. A hipótese testada é que ambos os tratamentos de superfície promoverão aumento da adesão entre zircônia e cimento resinoso, e de que a adição de uma camada de sílica reduzirá a resistência à flexão biaxial de discos Y-TZP, antes e após ciclagem mecânica; já o jateamento aumentará a resistência da cerâmica nas duas condições, seguindo o mesmo padrão para o limite de fadiga. Para o teste de adesão, 45 barras receberam um dos seguintes tratamentos de superfície (n = 15): controle: grupo controle, sem tratamento adicional após sinterização; silicatização: jateamento com partículas de SiO2 30 μm (Rocatec Soft, 3M ESPE); glaze: aplicação de uma única camada de vidro amorfo (Glaze Vita Akzent - Vita Zanhfabrik) e condicionamento com HF por 1 min. As amostras foram cimentadas (cimentação resinosa) à secções de cerâmica de dissilicato de lítio e, após 2500 ciclos térmicos, o teste de resistência adesiva à tração foi executado. Para avaliação das propriedades mecânicas, corpos de prova em forma de disco da cerâmica VITA In-Ceram 2000 YZ cubes for InLab foram confeccionados de acordo com as normas do ensaio de flexão biaxial. Os tratamentos de superfície avaliados são: controle; silicatização; e Glaze/HF. Os corpos de prova foram submetidos a flexão biaxial antes e após ciclagem mecânica (2 x 106 ciclos, 100 N, biaxial, imersão em água 37 ºC, 4 Hz). O método de escada foi utilizado para determinação do limite de fadiga dos corpos de prova, com 102, 103, 104 e 105 ciclos. A resistência adesiva foi maior para o grupo silicatização, seguido pelo grupo Glaze/HF e por ultimo o grupo controle, o qual não resistiu à ciclagem térmica. A ciclagem mecânica.. / The aim of this study is to evaluate the effect of different silica deposition methods on the surface of a zirconia ceramic on the adhesion to a resin cement and on the fatigue limit of the materials. The tested hypothesis is that surface treatments enhance the adhesion of resin cement to zirconia, and that the application of a silica layer reduces the flexural strength of zirconia discs, before and after mechanical cycling, and that air abrasion enhance the strength in both situations, following this patter also to fatigue limits. For the adhesive test, 45 bars received the following surface treatments (n = 15): control: without surface treatment after sintering; air-abrasion: 30 μm SiO2 particles (Rocated Soft, 3M ESPE); glaze: application of a thin layer of glaze (Glaze Vita Akzent - Vita Zanhfabrik), HF etching during 1 min plus silane. Samples were resin cemented to lithium dissilicate slices, and after 2,500 cycles of thermocycling, the tensile test was performed. Disc-shaped specimens were used for the evaluation of mechanical properties. The same surface treatments were performed on the tensile side of the samples. Specimens were submitted to biaxial flexural strength before and after mechanical cycling (2 x 106 cycles, 100 N, water immersion 37 ºC, 4 Hz). Stair case method was used to determine the fatigue limit of samples at 102, 103, 104 and 105 cycles. Adhesive strength was higher for air abraded group, compared to glaze group; control group did not survived thermocycling. Mechanical cycling had no effect on flexural strength. Air abrasion presented the highest values of flexural strength. Weibull analysis showed the highest m value for air abraded group without mechanical cycling, and the highest value was presented by glazed and mechanical cycled group. In stair case analysis, all groups presented a decrease in fatigue limit according to increase in number of cycles; air ...
12

Effect of ceramic density and curing pressure on properties of a resin infused alumina

Jokhadar, Hossam Faisal 25 October 2017 (has links)
OBJECTIVES: To investigate the effect of sintering temperature on the microstructure and density of resin infused alumina, to investigate effect of sintering temperature and curing pressure on flexural strength, surface roughness, Young’s modulus, hardness and fracture toughness of resin infused alumina. MATERIALS: Alumina infused polymer and Vita In-ceram alumina. METHODS: Alumina powders were dry-pressed in a stainless steel mold to produce cylindrical alumina blocks. Blocks were divided into four different groups sintered at four different temperatures (1050ºC,1150ºC,1200ºC,1250ºC). The density of each block was measured. They were silane treated, and then infused with a UDMA mixture under vacuum condition. Infused alumina blocks were cured with an Isopress machine at two different pressures (20,001 psi and 23,187 psi) then cut into discs 1.5 mm thick x 14 mm diameter, n=8 for each group. Biaxial flexural strength was measured using an Instron Universal Testing machine at 0.5 mm/min crosshead speed. Surface roughness was measured with a Mitotoyu profilometer. Hardness was measured using a Vickers hardness test using Instron-produced indentations at 15 newton load for 30 seconds. Young’s modulus was measured by compressive Young’s modulus method using the Instron machine at 0.5 mm/min crosshead speed. Fracture toughness was measured using the Vickers indentation fracture toughness test. Microstructure of each group was investigated with a scanning electron microscope (SEM). RESULTS: Data were analyzed with One-way ANOVA with Tukey-Kramer HSD for comparison of all pairs at p<0.05 was used to determine statistical difference between groups. CONCLUSION: The biaxial flexural strength, surface toughness, hardness, Young’s modulus and fracture toughness increase as density of resin infused alumina increases. Interpenetrating phase material provides greater biaxial flexural strength and fracture toughness than single-phase alumina ceramics. Curing pressure has a significant effect on the biaxial flexural strength of polymer infused alumina blocks. / 2019-09-26T00:00:00Z
13

Tratamento de superfície e adesão em materiais vitrocerâmicos experimentais para aplicação odontológica / Surface treatment and bonding in experimental glass-ceramic materials for dental application

Andrade, Gustavo Henrique Barbosa de 03 September 2015 (has links)
Materiais cerâmicos têm sido utilizados rotineiramente na clínica restauradora. A capacidade de adesão à sistemas adesivos de cimentação é um dos fatores críticos para o sucesso clínico. O objetivo do presente estudo foi avaliar as propriedades de adesão à um sistema de cimentação adesiva de dois materiais vitrocerâmicos experimentais, sendo um reforçado por dissilicato de lítio (D) e outro por metassilicato de lítio (M) para aplicação odontológica. Para tal, objetivou-se determinar a influência de diferentes tratamentos de superfície na resistência de união a um sistema de cimentação adesiva através de ensaios de microtração e caracterizar as alterações morfológicas decorrentes dos diferentes tratamentos de superfície testados. Três tratamentos de superfícies para cada material experimental foram selecionados: 1- jateamento com partículas de Al2O3 (J), 2- ataque ácido com ácido hidrofluorídrico a 10% por 20 segundos (20) e 3- ataque ácido com ácido hidrofluorídrico a 10% por 60 segundos (60). Um grupo do material comercial IPS e.max CAD (Ivoclar-Vivadent) foi utilizado como controle, seguindo as instruções do fabricante para o tratamento de superfície. As alterações morfológicas na superfície das cerâmicas foram analisadas por microscopia eletrônica de varredura (MEV) e demonstraram que os materiais experimentais são ácido sensíveis e sofreram modificações topográficas com o jateamento. Para os ensaios de microtração, os blocos das cerâmicas experimental e comercial tiveram suas superfícies condicionadas e silanizadas com o Agente Silano Relyx Ceramic Primer (3M ESPE), e posteriormente foram cimentados a blocos de resina composta Filtek Z100 (3M ESPE) com o cimento resinoso RelyX ARC (3M ESPE). Tais conjuntos foram seccionados, originando espécimes em forma de palito, com 1mm2 de área de secção transversal e submetidos ao ensaio de microtração. A análise estatística dos dados foi realizada por meio do teste de O teste utilizado foi o de Análise de Variância a um critério (One-Way ANOVA), adotando nível de significância de &#x3B1;=5%, O teste de Bonferroni foi utilizado para comparações múltiplas, demonstrando que os grupos D20 e M60 apresentaram melhores resultados de resistência de união. D20 não apresentou diferença estatística em relação ao grupo controle e M60 demonstrou resistência de união significantemente maior que o material comercial do grupo controle; levando, portanto, à conclusão de que os materiais experimentais testados apresentam características adequadas de adesão ao sistema de cimentação adesiva utilizado. / Ceramic materials have been routinely used in restorative clinic. The adhesion capacity to adhesive cementation systems is a critical factor for clinical success. The main objective of the present study was to evaluate the adhesion properties to an adhesive cementation system of two experimental vitroceramic materials, a reinforced by lithium dissilicate (D) and another by lithium metasilicate (M) for dental application. For this purpose, the objective was to determine the influence of different surface treatments on bond strength to an adhesive cementation system through microtensile tests and characterize morphological changes resulting from the different surface treatments tested. Three surface treatments for each experimental material were selected: 1- blasting with Al2O3 particles (J), 2- etching with hydrofluoric acid 10% by 20 seconds (20) and 3- etching with hydrofluoric acid 10% for 60 seconds (60). A group of the commercial material, IPS e.max CAD (Ivoclar-Vivadent) was used as control, following the manufacturer\'s instructions for surface treatment. Morphological changes on the surface of the ceramics were analyzed by scanning electron microscopy (SEM) and demonstrated that experimental materials are acid sensitive and suffered topographical changes with the blasting. For the microtensile tests, the blocks of experimental and commercial ceramics had their surfaces conditioned and silanized with Silane agent Relyx Ceramic Primer (3M ESPE), and then they were cemented to resin composite blocks (Z100 Filtek blocks - 3M ESPE) with the resin cement, RelyX ARC (3 m ESPE). These sets were sectioned, resulting in stick-shaped specimens, with 1 mm2 cross sectional area and submitted to the microtensile tests. The test used was the analysis of variance to a criterion (One-Way ANOVA), adopting a significance level of &#x3B1; = 5%, the Bonferroni test was used for multiple comparisons, demonstrating that the D20 and M60 showed best results of bond strength. D20 showed no statistical difference in relation to the control group and M60 demonstrated significantly bond streght better than the commercial material of the control group; leading to the conclusion that the experimental material tested has appropriate characteristics of adhesion to the cementation system used.
14

Efeito do processamento e da inclusão de fibras nas propriedades mecânicas e ópticas de uma porcelana odontológica / The effect of processing methods and fibers incorporation on the optical and mechanical properties of a dental porcelain

Araújo, Maico Dutra de 15 August 2011 (has links)
O objetivo dessa tese foi avaliar o efeito da adição de fibras e tipo de processamento (sinterização versus injeção) na microestrutura, propriedades mecânicas (resistência à flexão f e parâmetros de Weibull m, 0 e 5%), parâmetros de crescimento subcrítico (n e f0) e propriedades ópticas de razão de contraste (RC), parâmetro de translucidez (PT) e índice de opalescência (IO) de uma porcelana odontológica à base de leucita. Fibras de hexatitanato de potássio foram misturadas a uma porcelana à base de leucita que foi processada por sinterização e por injeção (com e sem fibras). Por meio de um estudo piloto realizado, variando-se temperaturas de sinterização e de injeção com 5% ou 10% de fibras, em massa, foram escolhidos o grupo controle (CS) sinterizado conforme recomendações do fabricante; o grupo sinterizado com fibras (SF), o grupo injetado sem fibras (ISF) e o grupo injetado com fibras (IF). A adição de fibras à porcelana processada por sinterização resultou em um material com fração volumétrica de poros mais do que duas vezes maior do que aquela encontrada para o grupo controle e a área média desses poros também foi mais do que o dobro da área média dos poros do controle. Outro problema apresentado pelo grupo sinterizado com fibras foi o aumento significativo da sua opacidade, representada pela razão de contraste que aumentou de 0,7 no controle para 1,0 no grupo sinterizado com fibras. Além disso, adição de fibras ao material processado por sinterização, apesar de ter causado aumento significativo da densidade e coeficiente de Poisson, não causou alterações significativas no módulo de elasticidade, dureza e tenacidade à fratura. Com relação à resistência à flexão biaxial, a adição de fibras na porcelana sinterizada causou aumento significativo da resistência média (f), porém os parâmetros da análise de Weibull (módulo de Weibull, m, resistência característica, 0, e resistência correspondente à probabilidade de falha de 5%, 5%) não foram alterados significativamente em relação ao grupo controle. Os parâmetros de crescimento subcrítico (coeficiente de susceptibilidade ao crescimento subcrítico, n, e resistência inicial, f0) também não foram alterados significativamente após a adição de fibras no material sinterizado. Embora o processamento por injeção sem adição de fibras não tenha afetado significativamente (em relação ao grupo controle) algumas propriedades como tenacidade à fratura, dureza, módulo de elasticidade, módulo de Weibull e 5%, houve um aumento significativo de parte das propriedades avaliadas como a resistência média, resistência característica e parâmetros de crescimento subcrítico. Com relação às propriedades ópticas, o processamento por injeção resultou em aumento da translucidez da porcelana, o que foi comprovado pela queda significativa no valor de razão de contraste e no aumento significativo no valor do parâmetro de translucidez em comparação com o grupo controle. Uma característica importante observada para o grupo injetado sem fibras foi seu baixo grau de porosidade em relação ao controle e também em relação aos outros dois grupos experimentais (SF e IF). Com relação ao grupo IF, o mesmo problema de alto grau de porosidade observado para o grupo sinterizado com fibras (SF) foi notado. Entretanto, os poros do grupo IF apresentaram área média significativamente menor e tamanho de poro aproximadamente 3 vezes menor do que os dos poros do grupo SF. Dentre as propriedades que não se alteraram comparando-se os grupos controle e injetado com fibras estão o módulo de elasticidade, coeficiente de Poisson, tenacidade à fratura, 5%, e as propriedades ópticas de razão de contraste e parâmetro de translucidez. Entretanto, é importante ressaltar que o grupo injetado com fibras obteve maiores valores médios em relação ao grupo controle para os seguintes parâmetros: densidade, dureza, resistência média, resistência característica, coeficiente de susceptibilidade ao crescimento subcrítico (foi o maior de todo o experimento) e resistência inicial (f0). / The objective was to evaluate the processing methods (conventional sintering and heat pressing) and fibers incorporation on the microstructure, mechanical properties (flexural strength f, and Weibull parameters m, 0 e 5%), slow crack growth parameters (n e f0) and contrast ratio (CR), translucency parameter (TP), opalescence parameter (OP) optical properties. Potassium Titanate fibers were mixed with a feldspathic porcelain, and then processed with conventional sintering and heat pressing (with or without fibers). A pilot study was carried out varying the sintering and heat pressing temperature with 5 or 10 wt% of fibers. The selected groups were the control group (CG), conventionally sintered processes following manufactures recommendations; conventionally sintered with fibers (SF); heat pressed without fibers (HP) and heat pressed with fibers (HPF). The hypothesis were: 1) The incorporation of fibers to the conventionally processed porcelain would improve the mechanical properties and slow crack growth parameters and would not affect the optical properties; 2) heat pressing the porcelain without fibers would improve the mechanical properties and slow crack growth parameters and would not affect the optical properties. 3) heat pressing the porcelain with fibers would improve the mechanical properties and slow crack growth parameters and would not affect the optical properties. Specimens were tested for biaxial flexural strength in water. Weibull analysis was used to determine m, 0 and 5% and the dynamic fatigue test was used to determine n e f0 values. The SF group showed percentage of porosity two times higher than the CG, higher values of f, but had no improvement on the Weibull parameters m, 0 and 5% values and slow crack growth parameters n and f0. It presented significant optical changes reaching 100% of opacity. The first hypothesis was partially accepted because there was increase only in f. The HP group presented 10 times lower porosity than CG. It showed higher values of f, and 0 but had no improvement on m and 5%. The HP group also showed higher values of n and f0 and significantly higher TP, and lower CR and OP. The second hypothesis was partially accepted as well because there were mechanical properties increases and changes in optical properties. The HPF group showed porosity two times higher than the CG, higher values of f, and showed an improvement on the Weibull parameters 0 and 5% and slow crack growth parameters n and f0. It presented significant changes OP.
15

Efeito do preenchimento e do material restaurador na resistência à fratura e distribuição de tensões de pré-molares superiores fragilizados /

Souza, Ana Carolina de Oliveira. January 2012 (has links)
Orientador: Alexandre Luiz Souto Borges / Coorientador: Tathy Aparecida Xavier / Banca: Rubens Nisie Tango / Banca: Lucas Villaça Zogheib / Resumo: O objetivo deste trabalho foi avaliar a influência do tipo de preenchimento e material restaurador na distribuição de tensões e resistência à fratura de pré-molares superiores tratados endodonticamente e com cúspides socavadas. Foram selecionados 40 pré-molares superiores humanos hígidos, sendo que 5 foram deixados intactos como controle (Grupo C+) e o restante realizado tratamento endodôntico e socavamento das cúspides. Cinco dentes foram separados para compor o controle negativo (Grupo C-), os demais foram divididos em dois grupos de acordo com o material de preenchimento (cimento de ionômero de vidro e resina composta) e realizados preparos para inlays. Foram então subdivididos em três grupos, sem restauração (PC: preenchimento com ionômero de vidro, PR: preenchimento com resina composta direta), restaurados com resina composta indireta (CS: preenchimento com cimento de iônomero de vidro e RS: preenchimento com resina composta direta) e os restaurados com cerâmica (CE: preenchimento com cimento de ionômero de vidro e RE: preenchimento com resina composta direta). As restaurações foram cimentadas com cimento resinoso dual e armazenadas em água destilada a 37 ºC por 24 h. Cada corpo de prova foi submetido a carga de compressão em máquina de ensaios universal, com velocidade de 1 mm/min. Os dados de resistência à fratura foram submetidos à análise de variância e ao teste de Tukey (5%). Os oito grupos formados foram modelados, importados pelo software Ansys 13.0, os volumes de cada geometria convertidos em elementos tetraédricos e submetidos á análise estática estrutural dentro do limite elástico e linear. Os resultados mostraram que a remoção de estrutura dentária afetou significantemente a resistência à fratura. Os menores valores foram... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to evaluate the influence of filling and restorative material on stress distribution and fracture resistance of premolars endodontically treated and weakened cuspal. Were selected 40 premolars healthy humans, 5 were left intact as controls (group C +) and others were performed endodontic treatment and removed the buccal and lingual dentin. Then 5 teeth were left to negative control (Group-C), the others were divided into two groups according to the filling material (glass ionomer and composite resin) and performed inlays prepares. They were then sudivided into three groups, no inlay restoration (PC: fill with glass ionomer, PR: fill with direct composite resin), restored with inlay made of indirect composite resin (CS: Fill glass ionomer (GIC) and RS: fill with resin composite) and restored with ceramic (EC: fill with VSD and RE: fill with resin composite). The restorations were cemented with dual cured resin cement and stored in distilled water at 37ºC/24h. Each specimen was compressed until the fracture in a universal testing machine with a 1mm/min of cross head speed. The eight groups were modeled, imported by software Ansys 13.0, the volume of each geometry were converted into tetrahedric elements and subjected to static structural analysis within the elastic limit and linear. Data fracture resistance were analysed by ANOVA and Tukey's test (5%). The results showed that removal of tooth structure affected significantly the fracture resistance values, the lowest were presented by the negative control group, followed by the groups restored and filled (no statistical difference between them) and all smaller than the control group positive. The different combinations of filling and restorative materials increased... (Complete abstract click electronic access below) / Mestre
16

Efeito de protocolos de cimentação na carga de fratura para uma cerâmica de dissilicato de lítio /

Carvalho, Rodrigo Furtado de. January 2014 (has links)
Orientador: Estevão Tomomitsu Kimpara / Co-orientador: Tarcisio José de Arruda Paes-Junior / Banca: Guilherme de Siqueira Ferreira Anzaloni Saavedra / Banca: Fabíola Pessôa Pereira Leite / Banca: Júlio César Brigolini de Faria / Banca: Vanessa Cruz Macedo / Resumo: Foi proposto avaliar a carga de fratura de restauração cerâmica à base de dissilicato de lítio (IPS e.max CAD) submetida a diferentes protocolos de cimentação. Foram confeccionadas 70 bases de um material resinoso análogo à dentina (NEMA grade G10) simulando de maneira padronizada dentes preparados para coroa total (término em chanfro com paredes de 6 graus de convergência) e a anatomia da raiz. A porção radicular foi coberta com poliéter e incluída em poliuretano. Setenta coroas cerâmicas foram fabricadas pelo sistema CAD/CAM. Depois de avaliar a espessura do filme de cimento (técnica do cimento análogo) as coroas foram limpas em ultra-som com água destilada (5 min). Posteriormente, as coroas foram submetidas a diferentes protocolos de cimentação: FZ-cimento de fosfato de zinco; IVMR-cimento de ionômero de vidro modificado por resina; RDCS-ácido fluorídrico 5 % (20 s) + silano (1 min) + cimento resinoso dual; RDCST-ácido fluorídrico 5% (20 s) + silano (1 min) + tratamento térmico forno 100 °C (2 min) + cimento resinoso dual; RDS-silano (1 min) + cimento resinoso dual; RDST-silano (1 min) + tratamento térmico forno 100 °C (2 min) + cimento resinoso dual; RAACS-ácido fluorídrico 5% (20 s) + silano (1 min) + cimento resinoso auto-adesivo. Todas as amostras foram submetidas à ciclagem termomecânica (2.000.000 ciclos - 100 N, 4 Hz, 5 ºC - 55 ºC, tempo de permanência 60 s), com um pistão de aço inoxidável (Ø=4mm) no centro da superfície oclusal. O teste da carga de fratura foi realizado em uma máquina de ensaios universal (v = 1 mm/min à 37 °C em água destilada). Os dados de carga de fratura (N) foram submetidos aos testes ANOVA (um fator) e Tukey, com α = 0,05. Realizou-se a análise de elementos finitos para verificação da distribuição das tensões na coroa. Por meio do microscópio eletrônico de varredura foram realizadas, em duas amostra de cada... / Abstract: It was proposed to evaluate the load of fracture of a ceramic restoration-based lithium disilicate (IPS e.max CAD) submitted to different protocols cementation. 70 bases were made of a resin material similar to dentin (NEMA grade G10) to provide standardized preparations, machined to simulate a tooth prepared for full crown (ending Bevel with walls of 6 degrees of convergence) and the anatomy of the root. The root portion was covered with polyurethane poliétere included. Seventy ceramic crowns were fabricated by CAD / CAM system. After evaluating the film thickness of cement (cement analogue technique) crowns were cleaned with distilled water in ultra-som (5 min). Subsequently, the crowns were subjected to different protocols cementation: FZ-zinc phosphate cement; IVMR-ionomer resin modified glass; RDCS-hydrofluoric acid 5% (20 s) + silane (1 min) + dual resin cement , RDCST-hydrofluoric acid 5% (20 s) + silane (1 min) + heat treatment furnace 100 °C (2 min) + dual resin cement; RDS-silane (1min) + dual resin cement; RDST silane (1 min) + heat treatment furnace 100 °C (2 min) + dual resin cement; RAACS-hydrofluoric acid 5% (20 s) + silane (1 min) + self-adhesive resin cement. All samples were subjected to thermomechanical cycling (2,000,000 cycles - 100N, 4 Hz, 5 ºC - 55 ºC, dwell time 60 s), with a stainless steel piston (Ø = 4 mm) in the center of the occlusal surface. The fracture toughness test was performed in a universal testing machine (v = 1 mm/min at 37 ° C in distilled water). Data fracture resistance (N) were subjected to ANOVA (one factor) and Tukey's test with α = 0.05. We conducted a finite element analysis to check the distribution of the stresses on the crown. Through scanning electron microscopy were performed on two samples from each group, representative photomicrographs of surface treatment . For fractographic analysis, we used the stereo type of fracture... / Doutor
17

Determinação do tempo de vida de restaurações totalmente cerâmicas (y-tzp/porcelana) com incidência da carga em diferentes regiões de contato /

Corazza, Pedro Henrique. January 2014 (has links)
Orientador: Álvaro Della Bona / Co-orientador: Estevão Tomomitsu Kimpara / Co-orientador: Jason A. Griggs / Banca: Humberto Lago de Castro / Banca: Márcia Borba / Banca: Alexandre Luiz Souto Borges / Banca: Rubens Nisie Tango / Doutorado Sanduíche no Exterior / Resumo: O objetivo do presente estudo foi comparar o tempo de vida e o modo de falha de restaurações totalmente cerâmicas (Y-TZP/porcelana) com aplicação da carga em diferentes regiões de contato, pelo método de vida acelerado step stress. Padrões de um material análogo à dentina (resina epóxica reforçada por fibras de vidro), simulando preparos para coroas totais de um primeiro molar inferior, foram obtidos e incluídos em resina poliuretano. Infra-estruturas (IE) de Y-TZP foram usinadas através de um sistema CAD-CAM, recobertas por uma porcelana e cimentadas aos padrões com um cimento resinoso dual (Panavia F). Os grupos foram divididos de acordo com as regiões de contato oclusal que ocorrem durante a função mastigatória (n = 20): contato na fossa central (CF), contato na cúspide (CC) e contato deslizante (CD). Nos grupos CF e CC a carga cíclica foi aplicada verticalmente nos pontos pré-selecionados, utilizando um pistão cerâmico usinado em CAD-CAM. Já no grupo CD, a carga vertical foi associada a um deslocamento lateral de 1 mm na vertente triturante da cúspide disto-lingual. Em todos os grupos, a frequência foi de 2 Hz. Diferentes perfis de estresse foram utilizados no experimento. As fraturas das restaurações foram detectadas com um monitor acústico acoplado ao ensaio. Uma distribuição de Weibull (intervalo de confiança de 95%) foi utilizada para analisar os dados. Quinze corpos de prova (CP) por grupo experimental, onde se conseguiu desprender a porção fraturada e gerar duas superfícies de fratura, foram analisados seguindo-se os princípios da fractografia. Os valores de estresse crítico de fratura (σf) foram obtidos. O valor de m (Módulo de Weibull) do grupo CF (2,1; 1,5-3,6) foi estatisticamente superior comparado ao m do grupo CD (0,7; 0,5-1,2). Não houve diferença estatística nos tempos de vida dos grupos CF e CD. A probabilidade de falha obtida ... / Abstract: The aim of the present study was to compare the life-time and failure mode of all-ceramic restorations (Y-TZP/porcelain) with load application on different contact points, by step stress accelerated life method. Dentin analog (epoxy filled with woven glass fibers) dies simulating a prepared mandibular first molar were obtained and embedded in polyurethane bases. The Y-TZP substructures (SB) were milled in a CAD-CAM system, veneered with a porcelain and cemented onto the dies using a dual resin cement system (Panavia F). The groups were divided according to the occlusal contact areas, based on masticatory function (n = 20): central groove load (CGL), cusp tip load (CTL) and sliding contact (SC). For the groups CGL and CTL, the cyclic load was applied vertically at the preselected points using a ceramic piston obtained in a CAD-CAM machine. For the SC group, the vertical cyclic load (also applied by a ceramic piston) was associated with a lateral displacement of 1 mm at the occlusal ridge of the disto-lingual cusp. The frequency was 2 Hz for all simulations. Different stress profiles, constants and progressives, were used. The fractures were detected with an acoustic device attached to the test. A Weibull distribution (95% of confidence boundary) was used to analyze the data. Fifteen specimens (SP) per group were examined following the fractography principles, and the critical stress at the fracture (σf) was calculated. The m value (Weibull modulus) of CGL (2.1; 1.5 - 3.6) was statistically greater than the m value of SC group (0.7; 0.5 - 1.2).There was no difference on the lifetime of the groups CGL and SC. The probability of failure obtained for a 300 N load and 200,000 cycles was statistically greater for CT (0.63; 0.44 - 0.81) compared to CG (0.23; 0.12 - 0.43). The failure mode of all specimens was chipping of the porcelain. For CTL, failure originated predominantly at the contact.... / Doutor
18

Desenvolvimento e validação de um novo protocolo para ciclagem térmica de materiais dentários /

Marinho, Caroline Cotes. January 2015 (has links)
Orientador: Estevão Tomomitsu Kimpara / Co-orientador: Fabíola Pessoa Pereira Leite / Banca: Vanessa da Cruz Macedo / Banca: Sérgio Eduardo de Paiva Gonçalves / Banca: Flávia Zardo Trindade / Banca: Josete Barbosa Cruz Meira / Resumo: Este trabalho teve como objetivos: avaliar a variação térmica que ocorre em ambiente bucal para predizer a quantidade e duração das variações de temperatura por dia, a temperatura máxima e mínima encontrada na cavidade oral e sugerir um novo protocolo de ciclagem térmica baseado nestas informações; e comparar os resultados de resistência de união após várias formas de envelhecimento. Para tal, foi instalado um sensor térmico wireless no palato de um aparelho parcial removível de seis voluntários, e estes foram monitorados durante três dias para desenvolvimento de um novo protocolo de ciclagem térmica. Após esta etapa, 40 blocos de cerâmica feldspática foram cimentados entre si (N=20), divididos em cinco grupos (n=4) e cortados em fatias. As fatias foram submetidas aos seguintes tipos de envelhecimento: C, teste imediato (sem envelhecimento); A, armazenagem em água por 30 dias; E, protocolo de ciclagem térmica experimental desenvolvido neste estudo; CIB, ciclagem intra-bucal; e ISO, protocolo de ciclagem térmica estabelecido pela norma ISO 11405 (2003). As fatias foram cortadas em palitos, os quais foram submetidos ao teste de microtração. A análise de falha foi realizada com o auxílio de um estereomicroscópio. A temperatura máxima encontrada foi de 47,59 ̊C, a mínima foi de 13,11 ̊C. A média de temperatura diária manteve-se entre 34 ̊C e 36 ̊C. A média de variação de temperatura por dia foi de 5,3 vezes, com duração média de 183 s. Os grupos A, CIB, E apresentaram valores de resistência de união estatisticamente menor que o grupo C (p-valor=0,0002), sendo semelhantes entre si. O grupo ISO foi semelhante aos grupos C e CIB. O modo de falha mais encontrado para todos os grupos foi do tipo mista. Conclui-se que ocorrem em média 6 variações térmicas por dia, com duração de 180 segundos. O protocolo de ciclagem térmica sugerido pela ISO não foi capaz de reduzir a resistência de uniâo. A ciclagem.. / Abstract: This study aimed to evaluate the thermal variation that occurs in the oral environment; predicted the number of thermal cycles and temperature variation which occurs during certain time periods and compared the results of the bond strength of ceramic and luting agent after different aging protocols. For this purpose, six volunteers used a removable device with wireless thermal sensor and they were monitored for three days, to develop a new thermal cycling protocol. After this step, 40 feldspathic ceramic blocks were cemented together with a resin luting agent (N = 20), divided into five groups (n = 4) and cut into slices. Aging of the slices were: C, immediate test (without aging); A, storage in water for 30 days; E, thermal cycling experimental protocol developed in this study; CIB, storage of the slices in mouth for 30 days; and ISO, thermal cycling protocol established by ISO 11405 (2003). The slices were cut into sticks for microtensile test. The failure analysis were performed in a stereomicroscope. Maximum temperature observed was 47.59 ̊C, the lowest temperature was 13.11 ̊C. The average daily temperature is between 34 ̊C and 36 ̊C. The average temperature change per day was 5.3 times, with an average duration of 183 s. A, CIB, and E groups showed strength values statistically lower than C group (p-value = 0.0002), and they were similar among them. The ISO group was similar to the groups C and IB. The failure type most commonly found for all groups was mixed mode. It concluded that occurs daily 6 temperature variations, with duration of 180 seconds. The ISO thermocycling protocol did not reduce the bond strength. The experimental cycling used in E, 180 thermal cycles with a temperature range of 50 ̊C and 10 ̊C for 180 seconds each and 36 ̊C intermediate baths was able to accelerate the degradation process of bond between ceramic and cement that occurred during storage in water for 30 days / Doutor
19

Confiabilidade de coroas com infraestrutura em zircônia sob fadiga deslizante: efeito do tipo de tratamento interno para cimentação /

Monteiro, Evelyn Barbosa Carmona. January 2014 (has links)
Orientador: Renata Marques de Melo Marinho / Banca: Marco Antonio Bottino / Banca: Paulo Francisco César / Resumo: O estudo avaliou a vida em fadiga de coroas cerâmicas com infraestrutura em zircônia (Vita In-Ceram® YZ) recobertas com cerâmica feldspática (Vita VM9). Foram utilizados 60 molares hígidos, preparados para coroa total e distribuídos em 3 grupos de acordo com o tratamento de superfície: primer (MDP); silicatização (Jateamento de óxido de alumínio 30 μm revestida por sílica + silano); vitrificação (glaze + ácido fluorídrico 10% + silano). A porcelana foi aplicada sobre os copings de zircônia seguindo a anatomia do primeiro molar superior. As coroas foram tratadas internamente, cimentadas com RelyX ARC e cicladas em máquina de fadiga deslizante (BIOPDI Sliding) na vertente interna da cúspide mésio vestibular. Para fadiga foi utilizada carga de 200 N, a 3 Hz de frequência e um pistão 3,18 mm de diâmetro, até falharem ou até completarem 2x106 ciclos. A cada 500.000 ciclos os espécimes foram inspecionados para verificar a presença de falhas, em estereomicroscópio. Para a determinação da confiabilidade foi feita a análise de Weibull, comum intervalo de confiança bilateral de 95%. As falhas predominantes foram trincas ocorrendo também falhas por lascamento e delaminação. Os parâmetros de Weibull (beta e eta) para os grupos primer, silicatização e vitrificação foram respectivamente: 1,51 e 1,6.106 ciclos; 1,50 e 0,739 .106 ciclos; 1,53 e 0,882. 106 ciclos. A confiabilidade de todas as coroas diminuiu com o tempo, mas as coroas que receberão o tratamento interno com um primer MDP apresentaram as taxas de sobrevivência mais elevadas. Significado Clínico: O uso de um primer MDP antes da cimentação de uma coroa com infraestrutura em zircônia pode aumentar a sua tolerância aos danos / Abstract: The aim of the present study was to evaluate the fatigue life of zircônia crowns veneered with feldspathic porcelain. Sixty first molars were selected, prepared for full crown and divided into 3 groups according to surface treatment: primer (MDP); tribochemical silica coating (Rocatec Soft + silane); glaze (Vita Akzent + Hydrofluoric acid 10 % + silane). The veneering porcelain was applied respecting the anatomy of upper first molar. The zirconia inner surface was treated according to the group, cemented using resin cement. The specimens were cycled in sliding fatigue machine (200N, 3Hz), using a piston of 3.18 mm diameter, on the inner side of the mesial buccal cusp, until specimens fail or up to 2x106 cycles. Every 500,000 cycles, the specimens were evaluated for the presence of flaws in stereomicroscope (10 ×). To determine the probability of survival (reliability), Weibull analysis was performed, considering a two-sided confidence interval of 95 %. The predominant type of failure was cracking and chipping of the feldsphatic porcelain followed by delamination. Weibull parameters (beta and eta) for primer, silica coating and glaze groups were respectively 1,51 and 1,6.106 cycles; 1,50 and 0,739.106 cycles; 1,53 and 0,882.106 cycles. The reliability of all crowns decreased with time, but the crowns cemented with an MDP primer presented higher survival rates. Clinical Significance: The use on an MDP primer before cementation of a veneered zirconia crown can increase its tolerance to damage / Mestre
20

Probabilidade de falha de coroas com infraestrutura em zircônia com diferentes geometrias /

Ramos, Gabriela Freitas. January 2014 (has links)
Orientador: Renata Marques de Melo Marinho / Banca: Alexandre Luiz Souto Borges / Banca: Flávia Pires Rodrigues / Resumo: Este estudo avaliou a probabilidade de falha de coroas de zircônia recobertas total ou parcialmente com cerâmica de cobertura e glaze, para determinação da sua confiabilidade por meio da análise de Weibull. Sessenta molares foram selecionados e preparados para coroa total, e divididos em três grupos (n = 20): Tradicional - infraestrutura em zircônia e cobertura total em porcelana; Modificada - infraestrutura em zircônia com cobertura parcial de cerâmica de cobertura (Vestibular) e; Monolítica - totalmente em zircônia. Em todos os espécimes, foi aplicada uma fina camada de vidro (glaze). Os espécimes foram submetidos à ciclagem mecânica (100 N, 3 Hz), com um pistão (Ø = 6 mm), até a falha dos espécimes ou até completar 2 x 106 ciclos. A cada 500.000 ciclos, os espécimes foram inspecionados quanto à presença de falhas, em estereomicroscópio (10×). Os tipos de falhas predominantes foram as trincas e o lascamento na cerâmica de cobertura, e também falhas por delaminação e descolamento da coroa. Os parâmetros de Weibull (beta e eta), com intervalo de confiança bilateral de 95% foram respectivamente: Tradicional - 1,25 e 0,09 E + 07 ciclos; Modificada - 0,58 e 1,16 E + 07 ciclos e Monolítica - 1,05 e 1,64 E + 07 ciclos. As coroas Tradicionais apresentaram maior susceptibilidade à falha por fadiga, as Modificadas apresentaram maior propensão a falhas precoces e as Monolíticas não demonstraram susceptibilidade à fadiga. As coroas Modificada e Monolítica apresentaram então maior número de coroas que não apresentam falhas após o teste de fadiga / Abstract: This study evaluated the failure probability of fully or partially porcelain / glaze veneered crowns, determining their failure probability with Weibull analysis. Sixty molars were selected and prepared for first molar full crown and divided into three groups (n = 20): Traditional -crowns with zirconia infrastructure covered with feldspathic porcelain; Modified - crown partially covered with veenering porcelain and Monolithic - Full countour zirconia crown. All specimens were treated with glaze layer. Specimens were submitted to mechanical cycling (100 N, 3 Hz) using a piston (Ø = 6 mm) until the specimens failure or up to 2 x 106 cycles. Every 500,000 cycles the specimens were inspected for the presence of flaws in stereomicroscope (10×). The predominant type of failure was cracking and chipping of the feldsphatic porcelain, followed by delamination and debonding . Weibull parameters (beta and eta), with two-sided confidence interval of 95 %, were respectively: Traditional - 1,25 and 0,09 E + 07 cycles ; Modified- 0,58 and 1,16 E + 07 cycles; Monolithic - 1,05 and 1,64 E + 07cycles. Traditional crowns showed greater susceptibility to fatigue, the Modified group presented higher propensity to early failures, and Monolithic showed no susceptibility to fatigue. Modified and Monolithic presented then highest number of crowns presenting no failures after the fatigue test. The three crown designs presented quite different behaviors under fatigue. The two modified groups presented less probability to failure after 2 x 106 cyles / Mestre

Page generated in 0.0711 seconds