• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • 14
  • 13
  • 13
  • 13
  • 13
  • 12
  • 2
  • 2
  • 1
  • Tagged with
  • 95
  • 95
  • 41
  • 34
  • 25
  • 24
  • 22
  • 17
  • 16
  • 15
  • 14
  • 13
  • 13
  • 13
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Comportamento mecânico de cerâmicas utilizadas na confecção de próteses parciais fixas / Mechanical behavior of ceramic materials used for fixed partial dentures

Borba, Marcia 23 June 2010 (has links)
Objetivos: determinar a resistência à flexão em três pontos (f), módulo de Weibull (m), coeficiente de susceptibilidade ao crescimento subcrítico de trinca (n) e tenacidade à fratura (KIC) de três cerâmicas usadas para confecção de infraestrutura (IE) de próteses parciais fixas (PPFs) (YZ- zircônia tetragonal parcialmente estabilizada por óxido de ítrio; IZ- cerâmica a base de alumina infiltrada por vidro e reforçada com zircônia; AL alumina policristalina) e duas porcelanas (VM7 e VM9); avaliar o efeito da configuração (uma, duas ou três camadas) nos valores de f e modo de fratura dos corpos-de-prova (CP); avaliar a influência do material de IE, do tamanho dos conectores e da ciclagem mecânica (CM) na carga de fratura (CF) e distribuição de tensões de PPFs; relacionar o comportamento mecânico dos materiais cerâmicos testados na configuração de barra e de PPF. Material e Método: Foram produzidos três tipos de CP em forma de barra (2mm x 4mm x 16mm): monolítico, duas camadas e três camadas. As IE das PPFs foram confeccionadas utilizando o sistema CAD-CAM e recobertas com porcelana. Os ensaios de f foram realizados em saliva artificial a 37ºC. Os valores de m e n foram determinados pela análise de Weibull e ensaio de fadiga dinâmica, respectivamente. As PPFs foram carregadas no centro do pôntico até a fratura. Oito PPFs de cada grupo foram submetidas a CM com freqüência de 2 Hz e carga de 140 N durante 106 ciclos e, posteriormente, ensaiadas até a fratura. A distribuição de tensões nas PPFs foi avaliada com análise de elementos finitos (AEF). Os princípios da fractografia foram utilizados para determinar o padrão de fratura e os valores de KIC. Os dados de f e CF foram analisados estatisticamente com Kruskal-Wallis e Tukey (95%). Resultados: A YZ obteve o maior valor de f (860 MPa) seguida dos materiais IZ (411 MPa) e AL (474 MPa) que não apresentaram diferença estatística. Os menores valores de f foram encontrados para as porcelanas (65 MPa). Os valores de m foram semelhantes para os materiais, com exceção dos grupos IZ e VM7, que apresentaram diferença significante. Os maiores valores de n foram encontrados para as cerâmicas YZ (76) e AL (72), seguidos pela IZ (54) e pelas porcelanas (40). A YZ apresentou o maior valor de KIC. O material submetido à tensão de tração durante o ensaio determinou o valor de f das estruturas. As PPFs de YZ com conector de 16mm2 suportaram os maiores valores de CF. Houve influência significativa do tamanho de conector para o material YZ. A CM não influenciou os valores de CF das PPFs. O padrão de distribuição de tensões foi semelhante entre as PPFs. Foi observada uma boa relação entre os valores de tensão de fratura dos materiais de IE em forma de barra e de PPF. Foram encontradas diferenças no modo de falha dos CP em forma de barra e de PPF. Conclusão: a YZ apresentou o melhor comportamento mecânico tanto na configuração de barra como de PPF. / Objectives: to determine the flexural strength (f), Weibull modulus (m), slow crack growth coefficient (n) and fracture toughness (KIC) of three ceramics used as framework materials for fixed partial dentures (FPDs) (YZ- yttria partially stabilized zirconia tetragonal polycrystals; IZ- alumina-based zirconia-reinforced glass infiltrated ceramic; AL alumina polycrystals) and two veneering porcelains (VM7 and VM9); to evaluate the effect of the specimen design (one, two or three layers) in the f and fracture mode; to evaluate the influence of the framework material, connector size and mechanical cycling (MC) in the fracture load (FL) and stress distribution of FPDs; to relate the mechanical behavior of the ceramic materials tested using bar-shaped specimens and FPDs. Materials and Methods: Bar-shaped specimens (2mm x 4mm x 16mm) were produced in three different designs: monolithic, bilayer and trilayer. FPD frameworks were built using CAD-CAM system and veneered with porcelain. Specimens were tested for three point bending in 37ºC artificial saliva. Weibull analysis and dynamic fatigue testing were used to determine m and n values, respectively. FPDs were tested with a load applied in the middle of the pontic. Eight FPDs of each group were subjected to MC using a frequency of 2Hz and load of 140N for 106 cycles and were subsequently loaded to failure. Stress distribution for FPDs was evaluated using finite element analysis (FEA). Fractography principles were used to determine the fracture mode and KIC values. f and FL data were analyzed using Kruskal-Wallis and Tukey (95%). Results: YZ had the highest f value (860 MPa) followed by IZ (411 MPa) and AL (474 MPa). Lower f values were observed for the porcelains (65 MPa). Except for IZ and VM7, m values were similar among the ceramic materials. Higher n values were found for YZ (76) and AL (72), followed by IZ (54) and the veneering materials (40). YZ presented the highest KIC value. The f values were influenced by the material subjected to tensile stress during testing. YZ FPDs with 16mm2 connector showed higher FL values. There was significant influence of the connector size on the FL values for YZ material. MC had no influence in the FL values for the FPDs. The stress distribution was similar for all FPDs. Considering the framework material, there was a good agreement between the fracture strength values obtained for bar-shaped specimens and FPDs. Different fracture modes were observed for bar-shaped specimens and FPDs. Conclusion: YZ presented the best mechanical performance in both bar-shaped and FPD specimen configuration.
42

Degradação da resistência de cerâmicas odontológicas após ciclagem mecânica / Resistance degradation of dental ceramics after cyclic loading

Lima, Erick de 23 September 2013 (has links)
Os objetivos deste trabalho foram: 1) avaliar o efeito do envelhecimento por ciclagem mecânica (3 milhões de ciclos a uma freqüência de 1 Hz) na resistência à flexão de quatro materiais cerâmicos utilizadas na confecção de próteses parciais fixas livre de metal: a) uma zircônia tetragonal policristalina estabilizada por ítria (Y-TZP); b) uma alumina policristalina (AL); c) compósito de alumina infiltrado por vidro (ICA) e d) um compósito de alumina e zircônia infiltrado por vidro (ICZ) e, 2) determinar o efeito da ciclagem mecânica no conteúdo de fase monoclínica de duas cerâmicas odontológicas contendo zircônia: a) zircônia tetragonal policristalina estabilizada por ítria e b) compósito de alumina e zircônia infiltrado por vidro. Material e método: Discos cerâmicos (12 mm x 1 mm) foram confeccionados conforme as recomendações dos fabricantes e testados em resistência à flexão biaxial. O grupo controle (sem ciclagem) de todos os materiais estudados foi submetido à estatística de Weibull para determinação da resistência característica (0) e módulo de Weibull (m). Os grupos envelhecidos mecanicamente foram fraturados em flexão biaxial e os valores obtidos foram comparados com seus respectivos grupos controle. A análise de difração de raios X (DRX) foi realizada para verificar do conteúdo de zircônia monoclínica. Resultados: Os valores médios de resistência à flexão apresentaram diferença estatisticamente significante para ambos os compósitos estudados, sendo que ICA apresentou diminuição no valor médio de resistência após a ciclagem mecânica (controle: 309,5 MPa; ciclado: 257,1 MPa) e ICZ, por outro lado, mostrou aumento da resistência após aplicação do protocolo de envelhecimento (controle: 315,6 MPa; ciclado: 359,1 MPa). As médias obtidas para materiais policristalinos foram semelhantes entre seus respectivos grupos ciclado e controle, com valores de 786,1 MPa (controle) e 841,7 MPa (ciclado) para Y-TZP e 383,5 MPa (controle) e 405,4 MPa (ciclado) para AL. Nos padrões de DRX das superfícies polidas de amostras de Y-TZP e ICZ dos grupos controle e ciclado foram observados apenas picos de difração correspondentes à fase da zircônia tetragonal. Conclusão: apenas o compósito ICA apresentou diminuição significativa nos valores de resistência à flexão após a aplicação do protocolo de ciclagem. Os outros materiais testados não sofreram degradação significativa da resistência mostrando, portanto, um melhor desempenho mecânico após uma simulação de três anos de utilização clínica. A ciclagem não causou aumento no conteúdo de zircônia monoclina nos materiais Y-TZP e ICZ / The objectives of this study were: 1) To evaluate the effect of aging by mechanical cycling (3 million cycles at a frequency of 1 Hz) on the biaxial flexural strength of four dental ceramics used as framework for the manufacture of metal free fixed partial dentures: a) yttria partially stabilized zirconia tetragonal polycrystals (Y-TZP), b) alumina polycrystals (AL), c) alumina glass infiltrated ceramic (ICA) and d) alumina-based zirconia-reinforced glass infiltrated ceramic (ICZ); and 2) to determine the effect of mechanical cycling on the monoclinic zirconia content of two dental ceramics: a) yttria partially stabilized zirconia tetragonal polycrystals (Y-TZP) and b) alumina-based zirconia-reinforced glass infiltrated ceramic. Materials and Methods: Disc-shaped specimens (12 mm x 1 mm) were prepared according to manufacturer\'s recommendations and tested in biaxial flexure strength. The control group (no cycling) of all materials studied was subjected to Weibull statistics to determine the characteristic strength (0) and Weibull modulus (m). After mechanical aging, the specimens were fractured and the values obtained were compared with their respective control groups. The X-ray diffraction (XRD) analysis was performed to analyze the monoclinic zirconia content. Results: The mean values of flexural strength showed statistically significant differences for both composites studied, being that the ICA showed a decrease in the average value of resistance after mechanical cycling (control: 309.5 MPa; cycled: 257.1 MPa) and ICZ, on the other hand, showed increase in the resistance after application of the cycling protocol (control: 315.6 MPa; cycled 359.1 MPa). The means obtained for polycrystalline materials were similar between the respective groups cycled and control, with values of 786.1 MPa (control) and 841.7 MPa (cycled) for Y-TZP and 383.5 MPa (control) and 405.4 MPa (cycled) for AL. In the XRD patterns of the polished surfaces of Y-TZP and ICZ samples both cycled and control groups were observed only diffraction peaks corresponding to the tetragonal phase of zirconia. Conclusion: Only the composite ICA showed significant decrease in flexural strength values after applying the cycling protocol. The other materials tested did not suffer significant degradation resistance showing great mechanical performance after a simulated three years of clinical use. The mechanical cycling did not cause increase in the content of monoclinic zirconia in Y-TZP and ICZ.
43

Efeito de diferentes tratamentos de superfície na resistência de união, ângulo de contato, morfologia e análise da distribuição de tensão de laminados ultrafinos de cerâmica reforçada por dissilicato de lítio /

Escobar, Lorena Cristina Bogado. January 2017 (has links)
Orientador: Maria Filomena Rocha Lima Huhtala / Banca: Alexandre Luiz Souto Borges / Banca: Marcelo Giannini / Resumo: Laminados cerâmicos são utilizados em tratamentos conservadores para restabelecer estética e função com mínimo desgaste da estrutura dental. O objetivo deste estudo foi avaliar, in vitro, o efeito de dois tratamentos de superfície em espécimes cerâmicos ultrafinos de dissilicato de lítio na resistência de união com o cimento resinoso. Laminas ultrafinas de cerâmica (14 X 12 X 0,3 mm) foram distribuídas aleatoriamente em dois grupos (n=20) de acordo com o tratamento de superfície: ácido hidrofluorídrico 5% durante 20 s e silano (HF) e Monobond Etch & Prime (Ivoclar, Vivadent) por 60 s (MEP). Dois cilindros de cimento resinoso foram confeccionados utilizando matrizes cilíndricas. Após 24 h de armazenamento, os espécimes foram submetidos ao ensaio mecânico de microcisalhamento (1 mm/min) e o modo de falha foi estabelecido. Dados de resistência de união foram analisados pelo teste t de Student (α=0.05). O ângulo de contato foi determinado. Análise morfológica das superfícies cerâmicas por meio de microscopia de força atômica e eletrônica de varredura foi realizada. Através de análise por elementos finitos foi estudada a distribuição de tensão em incisivos centrais superiores restaurados com laminados cerâmicos ultrafinos de dissilicato de lítio (0,3 mm). O modelo tridimensional foi elaborado no software Rhinoceros e exportado para software de análise Ansys. Foram modelados e analisados 04 grupos sob duas condições: desgaste ou não de esmalte e tipo de preparo. Foi aplicada uma ca... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Laminate veneers are becoming a technique used in the conservative treatments by the ability to restore aesthetics and function. This study aimed to evaluate, in vitro, the effect of two surface treatments on ultrathin lithium disilicate specimens in bond strength between treated ceramics and resin cement. Ceramic ultrathin laminates (12 X 14 X 0.3 mm) were obtained and randomly distributed into two groups (n=20) according to the surface treatment: 5% hydrofluoric acid for 20 s and silane (HF) and Monobond Etch & Prime (Ivoclar, Vivadent) for 60 s (MEP). Two resin cement cylinders were made using cylindrical matrices. After 24 h storage, microshear bond strength tests were performed in a universal testing machine (1 mm/min) and failure mode was analyzed. Bond strength data were submitted to Student's t-test (α=0.05). The contact angle was measured. Micromorphogical analyses of representatives specimens were also performed (atomic force and scanning electron microscopy). Finite element analysis studied the distribution of stress in maxillary central incisors restored with ultrathin laminate veneers of lithium disilicate (0.3 mm). 3D model was elaborated in CAD Rhinoceros® software and exported to analysis software Ansys®. Four groups were modeled and analyzed under two experimental conditions: wear or non-enamel and type of preparation. A load of 100 N was applied at the palatal face. The stress was analyzed by Maximum Principal Stress criteria. Microshear bond strength values... (Complete abstract click electronic access below) / Mestre
44

"Avaliação quantitativa e qualitativa de duas cerâmicas frente a diferentes tratamentos de superfície" / Quantitative and qualitative evaluation of the two ceramics in differents surfaces tratment

Agra, Carlos Martins 01 September 2005 (has links)
A característica de superfície representa um fator importante na previsibilidade do comportamento dos materiais cerâmicos quanto ao desgaste. A rugosidade superficial de duas cerâmicas (Duceram Plus e Duceragold) foi avaliada através de dois métodos - análise quantitativa e qualitativa - após diferentes tratamentos. Foram confeccionados 36 corpos de prova de prova para a análise ao rugosímetro, e 24 corpos de prova para a análise ao MEV. Os resultados destas análises demonstraram o comportamento distinto entre os diferentes tratamentos. A análise com o rugosímetro demonstrou que a ação dos polidores EDENTA foi a mais efetiva para devolver lisura à superfície após a realização de desgaste com instrumento abrasivo diamantado rotatório. Todas as técnicas de polimento acarretaram em valores de rugosidade menores que os observados nos espécimes que foram submetidos apenas os “glaze". Entre as cerâmicas avaliadas, a Duceragold apresentou valores médios de rugosidade inferiores aos observados na porcelana Duceram Plus na maioria dos tratamentos pesquisados. Pela análise ao MEV não foi possível distinguir diferenças entre as cerâmicas ou entre os corpos de prova polidos ou submetidos apenas ao “glaze". / The surface characteristic of ceramic material is an important factor to predict its wear behavior. The surface roughness of two ceramics (Duceram Plus e Duceragold) was evaluated trough qualitative and quantitative methods after different treatments. 36 specimens were fabricated for the analysis utilizing a surface profiling instrument, and 24 for the SEM analysis. The results determined different behavior between the two ceramics evaluated due the treatment executed. The analysis utilizing a surface profiling instrument showed that the treatment using the EDENTA polishers was the most effective technique to provide the smoothest surface after trimming. All polishing techniques resulted in better surface properties when compared to the treatment glaze. The Duceragold ceramic presented lower roughness values in most treatments executed when compared to Duceram Plus. The perception trough the SEM analysis of significant differences between treatments or between the two ceramics was not achievable.
45

Influência do tipo de sistema de infra-estrutura na adaptação e microinfiltração de coroas totais cerâmicas / Influence of the type of framework system in the adaptation and microleakage of all-ceramic crowns

Cavalcanti, Maria Tereza Moura de Oliveira 04 April 2008 (has links)
Os objetivos deste trabalho foram: a quantificação da microinfiltração e desadaptação antes e após cimentação de coroas totais cerâmicas, com quatro tipos de sistemas de infra-estrutura e a correlação entre desadaptação e microinfiltração. Após aprovação pelo Comitê de Ética da FOUSP, 40 terceiros molares humanos receberam coroais totais cerâmicas, sendo: 2 cerâmicas infiltradas por vidro (In-Ceram alumina Slip-Cast (S) e o bIoco In-Ceram Alumina CA-12 (CA)) e 2 cerâmicas de alumina policristalina (Procera/Nobel Biocare (P) e o bloco In-Ceram Al-20, CEREC In-Lab (CE)), (n=10). O espaço entre coroa e dente foi medido antes e depois da cimentação das coroas. Foram submetidos à ciclagem mecânica (100.000 ciclos, 8 Kgf, 4 Hz), térmica (700 ciclos, 5/55ºC por minuto), submersos em azul de metileno 0,5% por 4 horas e seccionados nos sentidos mésio/distal e vestíbulo/lingual. As imagens foram obtidas em estereomicroscópio (20X) e os dados de desadaptação foram submetidos à ANOVA (e Tukey). Os escores da microinfiltração foram submetidos à análise da concordância dos avaliadores e Kruskal-Wallis. Não houve diferenças significantes entre os sistemas cerâmicos (S= 38, P= 49, CA= 48 e CE= 39?m). O fator \"região\" da linha de cimentação apresentou diferenças estatísticas. A desadaptação foi maior na parede pulpar (60 ?m), seguida dos ângulos axio-pulpar e gengivo-axial (57 e 48 ?m, respectivamente). As paredes axiais e margens foram os locais de menor desadaptação (27 e 26 ?m, respectivamente). Houve diferença estatística entre as duas técnicas de medida, antes e após a cimentação (46 e 41?m, respectivamente). Houve diferença estatisticamente significante entre os quatro tipos de sistemas cerâmicos avaliados quanto à microinfiltração, onde S e CE apresentaram maiores níveis de infiltração, seguidos de P e CA. Não houve correlação entre microinfiltração e desadaptação. Concluiu-se que os quatro sistemas cerâmicos avaliados produziram coroas totais com linha de cimentação dentro dos limites clinicamente aceitáveis. / The objectives of this study were to quantify the microleakage and the loss of marginal adaptation before and after cementation of all-ceramic crowns, with four types of infrastructure systems, and to compare these parameters. After approval by the Committee on Ethics in Research of Dental School of University of São Paulo, 40 human third molars received all-ceramic crowns, 2 glass-infiltrated ceramics (In-Ceram alumina Slip-Cast (S) and the block In-Ceram Alumina CA-12 (CA) ) and 2 polycrystalline alumina ceramics (Procera / Nobel Biocare (P) and the block Ceram In-Al-20, CEREC In-Lab (EC) (n = 10). The gap between ceramic dental prosthesis and tooth was measured before and after cementation of the crowns. They were subjected to mechanical load cycling (100,000 cycles, 8 Kgf, 4 Hz), thermocycling (700 cycles, 5 / 55 ° C per minute), immersed in 0.5% methylene blue dye for 4 hours and then sectioned in the mesial / distal and buccal / lingual aspects. The images were obtained in stereomicroscope (20X) and the marginal fit data were evaluated by ANOVA (and Tukey test). The microleakage values were analyzed by the correlation analysis of examiners and the Kruskal-Wallis test. There were no significant differences between the ceramic systems (S = 38, P = 49, CA = 50 and CE = 39 ? m). The factor \"region\" of the cementation line has presented statistical differences. The loss of adaptation was higher on the pulpal wall (61 ? m), followed by gingival-axial (49 ? m) and axial-pulpal (58 ? m) angles. The axial walls and margins were the sites of the smallest displacement (27 and 26 ?m, respectively). There was statistical difference between the two techniques of measurement, before and after cementation (47 and 41 ?m, respectively). Statistically significant difference among the four types of ceramic systems was detected for microleakage, whereas S and CE showed higher levels of infiltration, followed by P and CA. However, no correlation was found between microleakage and loss of marginal adaptation. It was concluded that the four systems produced all-ceramic crowns with the line of cementation within clinically acceptable limits.
46

Efeito de diferentes espessuras, técnicas de aplicação e protocolos de resfriamento na resistência à fratura da cerâmica de cobertura aplicada sobre infraestrutura de y-tzp /

Lima, Júlia Magalhães da Costa. January 2014 (has links)
Orientador: Marco Antonio Bottino / Banca: Paulo Francisco César / Banca: Susana Salazar Marocho / Banca: Renata Marques de Melo / Banca: Alexandre Luiz Souto Borges / Resumo: O objetivo desta pesquisa foi avaliar, in vitro, a influência do resfriamento, da técnica de aplicação e do efeito da espessura da cerâmica de cobertura na carga de fratura de coroas totalmente cerâmicas com infraestrutura de zircônia. Foram confeccionadas 100 infraestruturas de zircônia (Y-TZP) com 1,0 mm de espessura. 80 infraestruturas foram divididas em 8 grupos (n = 10) para confecção de 80 coroas de acordo com os fatores "técnica de aplicação" (estratificada e prensada), "espessura" (1 mm e 2 mm) e "protocolo de resfriamento" (lento e rápido) da cerâmica de cobertura. Com as outras 20 infraestruturas foram confeccionadas 20 coroas pela técnica CAD/CAM/Rapid Layer e divididas em 2 grupos (n = 10) de acordo com o fator "espessura da cerâmica de cobertura" (1 mm e 2 mm) e foi realizada Análise de Elementos Finitos. Todos os espécimes foram ciclados mecanicamente (200 N; 2 x 106 ciclos; 3,0 Hz; água/ 37 °C). A presença de chipping foi avaliada através de análise em estereomicroscópio após a ciclagem mecânica. Em seguida, todos os espécimes foram submetidos ao teste de resistência à fratura em compressão axial (0,5 mm/minuto; 10 kN). As coroas foram analisadas para determinar a possível origem da falha. Os dados (N) obtidos foram submetidos à análise estatística, com o Teste de Dunnett, teste t-Student, para a técnica CAD/CAM/Rapid Layer, e ANOVA 3-fatores e teste de Tukey para as demais técnicas. A carga de fratura das coroas confeccionadas pela técnica CAD/CAM/Rapid Layer, independente da espessura, foi menor em relação às outras duas técnicas (p < 0,05), mas houve diferença significativa entre as duas espessuras das coroas confeccionadas por esta técnica. Houve influência dos fatores resfriamento (p = 0,0058) e técnica de aplicação (p = 0,0001) na análise das técnicas estratificada e prensada. O resfriamento lento diferiu.... / Abstract: The aim of this study was to evaluate the in vitro influence of cooling protocols and application techniques and the effect of the thickness of veneering ceramics on the fracture resistance of prosthetic crowns. For this purpose, 100 'zirconia partially stabilized by yttrium oxide' frameworks (1 mm thick) were made. Eighty frameworks were divided into 8 groups (n = 10) according to the application technique (stratified or pressed), thickness (1 or 2 mm), and the cooling protocol (slow or fast) of the veneering ceramic. With the remaining 20 frameworks, 20 crowns were prepared by the CAD/CAM/Rapid Layer technique and were divided into 2 groups (n = 10) according to the veneering ceramic thickness (1 or 2 mm); these were also evaluated by Finite Element Analysis. All specimens were mechanically cycled (200 N, 2 x 106 cycles; 3.0 Hz; water at 37 °C). Chipping presence was evaluated by stereomicroscopy after mechanical cycling. All specimens were tested for compressive strength (0.5 mm/minute; 10 kN). We analyzed crowns to determine the possible beginning of the failures. Data, in N, were statistically analyzed with Dunnett's, t-test, 3-way ANOVA, and Tukey's tests. The fracture load of the CAD/CAM/Rapid Layer crowns was lower, regardless of ceramic thickness, when compared with the other two application techniques tested (p < 0.05). We observed an influence of the cooling protocol (p = 0.0058) and the application technique (p = 0.0001) in the analysis of stratified and pressed techniques. Slow cooling differed from rapid cooling in the pressed ceramic crowns; however, this difference was not observed for the stratified crowns, regardless of the thickness of the veneering ceramic. Failures in the CAD/CAM/Rapid Layer crowns began predominantly at the interface between the resin cement and veneering ceramic, resulting in delaminations of the veneering ceramic, while the other techniques .... / Doutor
47

Efeito de protocolos de jateamento na resistência à flexão e transformação de fase cristalina em cerâmicas de Y-TZP /

Turci, Priscilla Cristoforides Pereira. January 2014 (has links)
Orientador: Rubens Nisie Tango / Banca: Guilherme de Siqueira Ferreira Anzaloni Saavedra / Banca: João Paulo Barros Machado / Banca: Paulo Francisco César / Banca: Alberto Noriyuki Kojima / Resumo: O objetivo deste estudo foi avaliar o efeito de diferentes protocolos de jateamento na resistência à flexão biaxial e transformação de fase cristalina de cerâmica policristalina de Y-TZP. Foram confeccionados 740 discos de zircônia estabilizada parcialmente por ítrio - Cercon®Zirconia (DENTSPLY Ceramco, EUA) e In Ceram 2000 YZ cubes (Vita Zahnfabrik, Alemanha) segundo a norma ISO 6872 (15 mm diâmetro x 2 mm espessura). As amostras foram jateadas com partículas de óxido de alumínio (30 μm) revestido por sílica (RocatecSoft - 3M ESPE) e divididas em 74 grupos (n = 10), incluindo-se os grupos controle (ausência de jateamento)(n = 10) para cada cerâmica, de acordo com os fatores: pressão de jateamento (2, 3 e 4 bar); ângulo formado entre a ponta do jateador e a superfície da cerâmica (45º, 60º, 90º); distância do microjateador à cerâmica (5 e 10 mm) e tempo de jateamento (15 s e 20 s). Foi realizado teste de resistência à flexão biaxial em máquina de ensaio universal (1 mm/min, 1000 kg). Os dados (MPa) foram submetidos a análise de variância e ao teste de Duncan. Parte das amostras (n=3) foram submetidas à difração por raios-X (DRX) para quantificação das fases cristalinas e à microcopia eletrônica de varredura (MEV) para análise da topografia superficial. Pressão (p = 0,00) afetou significativamente os resultados, porém tempo (p = 0,49), distância (p = 0,46) e angulação (p = 0,13) não afetaram a Cercon. Já para Vita YZ, a pressão (p = 0,00) foi estatisticamente significante, porém tempo (p=0,66), distância (p = 0,70) e angulação (p=0,14) não foram. Fase monoclínica foi encontrada nos grupos da Cercon (0 a 11%), enquanto para Vita YZ, nenhuma fase foi encontrada. Para Vita YZ, a pressão 3 bar teve maior resistência à flexão biaxial e 4 bar apresentou menor valor. Angulação de 45° associado a 2 bar foi a melhor combinação (1012,21 ± 108,36 MPa)... / Abstract: The aim of this study was to evaluate the effect of different sandblasting protocols on biaxial flexural strength and crystalline phase transformation in Y - TZP ceramic. 740 discs of Yttria-Partially-Stabilized Zirconia were made - Cercon ® Zirconia (DENTSPLY Ceramco, USA) and In Ceram 2000 YZ cubes (Vita Zahnfabrik, Germany) according to the standards of ISO 6872 (15 mm diameter x 2 mm thick) . The samples were sandblasted with aluminum oxide - coated silica 30 μm (Rocatec Soft - 3M ESPE ) and divided into 74 groups (n = 10 ) , according: pressure (2, 3 and 4 bar) ; nozzle angle (45°, 60°, 90°); nozzle distance (5 and 10 mm) and time (15 s and 20 s) . The biaxial flexural strength on universal testing machine (1mm/min, 1,000 kg) was performed. Data (MPa) were submitted to ANOVA and to Duncan's test (α = 0.05). Samples (n = 2) were subjected to X- ray diffraction to quantify crystalline phases. Pressure (p = 0.00) significantly affected the results, but deposition time (p = 0.49), nozzle distance (p = 0.46) and nozzle angles (p=0.13) did not affect to Cercon ceramic. Pressure (p = 0.00) affected significantly the results to Vita YZ, but deposition time (p = 0.66), nozzle distance (p = 0.70) and nozzle angles (p = 0.14) did not affect. Some monoclinical phase was achieved in Cercon groups (0 a 11%) and none for Vita YZ. For Vita YZ ceramic, 3 bar pressure had the biggest flexural strength value and 4 bar was the worst one and angle 45° associated to 2 bar were the best combination (1012.21 ± 108.36 MPa) compared to 4 bar (556.65 ± 117.41 MPa) (p < 0.001). EDS analysis demonstrated regular superficial grains. SEM images indicated grain size of 0.712 μm (Vita YZ), and 0.705 μm (Cercon). The Cercon density was 98% compared to the theoretical density of zirconia, while VITA YZ was 99% / Doutor
48

Restaurações cerâmicas minimamente invasivas executadas por cirurgiões dentistas com diferentes níveis de experiência profissional : estudo clínico cego, longitudinal e prospectivo /

Melo, Régis Alexandre da Cunha. January 2015 (has links)
Orientador: Eduardo Passos Rocha / Banca: Paulo Henrique dos Santos / Banca: Rodolfo Bruniera Anchieta / Resumo: Objetivo: Avaliar a influência da experiência profissional de cirurgiões-dentistas na taxa de sobrevida de restaurações cerâmicas delgadas cimentadas sobre dentes anteriores e/ou posteriores. Material e Método: Um total de 16 profissionais em nível de especialização realizaram tratamentos restauradores com cerâmica delgada, que foram divididos em quatro grupos (n=4) de acordo com o tempo de formação profissional - Grupo 1: recém-formados com até 2 anos de formados; Grupo 2: de 2 a 5 anos de formado; Grupo 3: de 5 a 10 anos de formado; Grupo 4: mais de 10 anos de formado. Todos os profissionais foram instruídos e treinados a seguirem o mesmo protocolo clínico de trabalho, embora desconhecessem os objetivos da pesquisa. Um único avaliador acompanhou os atendimentos clínicos realizados em 24 pacientes, totalizando 274 restaurações unitárias em dissilicato de lítio, sendo 158 na região anterior e 116 na posterior, distribuídas entre os arcos maxilar (186) e mandíbular (88). A espessura das cerâmicas variou entre 0,3 mm e 4,0 mm. As intercorrências ocorridas durante a execução dos protocolos clinicos, bem como os tempos de condicionamento ácido, de fotopolimerização e o tipo de cimento foram anotados. As restaurações foram cimentadas com diferentes cimentos em função da espessura da cerâmica, sendo: Rely X U200 (n=120), Rely X Veneer (n=95) e Variolink Veneer (n=58); totalizando 91 coroas totais, 137 facetas com preparo e 46 facetas sem preparo. As avaliações clínicas foram realizadas após a instalação das restaurações e nos controles de 30, 180, 360 dias posteriores à cimentação. Os parâmetros para a avaliação foram baseados nos critérios modificados do USPHS, adaptados ao estudo. Julgou-se insucesso quando houve fratura ou soltura das restaurações. As fraturas foram replicadas e submetidas à análise... / Abstract: Objective: To evaluate if the dentist experience can influence the survival rate of cemented anterior and/or posterior thin ceramic restorations. Materials and Methods: A total of 16 professionals with different expertise level with thin ceramic restorations were divided into four groups (n=4) - Group 1: up to 2 years of the graduation; Group 2: 2 to 5 years of graduation; Group 3: 5-10 years of graduation; Group 4: more than 10 years of graduation. All professionals have been educated and trained to follow the same clinical protocol, but were unaware of the research objectives. A single evaluator accompanied the clinical treatments performed in 24 patients, totaling 274 single restorations in lithium disilicate, 158 in the anterior region and 116 in the posterior distributed region among the arches, 186 in the maxillae and 88 in the jaw. The thickness of the ceramic varied between 0.3 mm and 4.0 mm. Minor complications that occurred during the execution of the protocols, the etching and the light curing times and the type of cement were recorded. The restorations were cemented with different cements according to the thickness of ceramic, which: Rely X U200 (n = 120), Rely X Veneer (n = 95) and Variolink® Veneer (n = 58); totaling 91 full crowns, 137 laminated with preparation and 46 laminated with no prepare. Clinical assessments were performed after the installation of the restorations and at the controls of 30, 180 and 360 days after the cementing period. The parameters for evaluation were based on the modified USPHS criteria, adapted to the study. It was deemed unsuccessful when there was fracture or loosening of the restorations. Fractures were replicated and submitted to fractographic analysis. Results: The least number of failures were observed in Group 2 (1 debonding), the largest number in Group 1 (5 fractures) and highest... / Mestre
49

Efeito da infiltração de sílica pelo método sol-gel na resistência à flexão de bicamadas de porcelana e Y-TZP /

Reis, Ana Flavia Nunes. January 2015 (has links)
Orientador: Renata Marques de Melo Marinho / Banca: Alexandre Luiz Souto Borges / Banca: Leonardo Buso / Resumo: O objetivo deste trabalho foi infiltrar sílica em uma cerâmica Y-TZP, avaliar seu efeito na resistência à flexão Biaxial, e na união com a porcelana feldspática. Para a análise da resistência à flexão foram confeccionados 180 discos de zircônia, 120 de 0,5mm e 60 com 1,2mm discos (14 mm de diâmetro). 90 discos foram infiltrados com sílica pelo método sol-gel em temperatura ambiente (n = 30). A espessura do disco foi de 1,2 mm para os espécimes controle (espécime sem porcelana, n = 30). O recobrimento por porcelana feldspática foi de duas espessuras (0,5mm e 1 mm) sobre a zircônia que tinha 0,5 mm. Os espécimes com porcelana foram polidos com lixas de carbeto de silício (SiC) de granulação # 400, 600, 800 e 1200. Obtivemos 6 grupos: dois monolíticos (ZR- Zircônia Monolítica sem infiltração e ZRI- Zircônia Monolítica Infiltrada) (controle) e quatro estratificados: ZRF 1,0 (0,5mm Zircônia coberta com 0,5 mm porcelana), ZRIF 1,0 (0,5 mm Zircônia infiltrada coberta com 0,5 mm de porcelana), ZRF 1,5 (0,5 mm Zircônia infiltrada coberta com 1,0 mm de porcelana) ZRIF 1,5- Zircônia infiltrada (0,5 mm Zircônia infiltrada coberta com 1,0 mm de porcelana). Após o ensaio de flexão biaxial em meio aquoso, foram determinados o módulo de Weibull (m) e resistência característica (σθ). Os fragmentos foram analisados em EDS, MEV, DRX e FTIR. A Dureza (H) e tenacidade a fratura foram analisadas pela nanoindentação, já o módulo elástico (E) por duas técnicas, nanoindentação e por impulso, e para avaliar a adesão entre a zircônia e a porcelana foi aplicado o Teste de Scratch. Foram modeladas 7 condições experimentais e analisados pelo método por elementos finitos. A zircônia monolítica infiltrada mostrou uma estrutura com grãos arredondados envoltos em uma matriz de sílica, e a presença de zircônia cúbica e tetragonal. O DRX revelou a formação de ZrSiO4 nos grupos infiltrados. Os grupos monolíticos... / Abstract: The objective was to infiltrate silica in a Y- TZP ceramics, evaluate its effect on resistance biaxial strenght, and the union with feldspathic porcelain. For the analysis of flexural strength were prepared zirconia discs 180, 120 and 60 of 0.5 mm to 1.2 mm disks (14 mm diameter). 90 discs were infiltrated with silica by the sol-gel method at room temperature (n = 30). The thickness of the disk was 1.2 mm for the samples control (no porcelain specimen, n = 30). The coating was feldspathic porcelain by two thicknesses (0.5 mm and 1 mm) of zirconia, which had 0.5 mm. Specimens with porcelain were polished with sandpaper silicon carbide (SiC) granulation # 400, 600, 800 and 1200. We obtained six groups: two monolithic (Zr-Zirconia Monolithic without infiltration and ZRI- Zirconia monolithic Infiltrated) (control) and four laminated ZRF 1.0 (0.5 mm zirconia covered with 0.5 mm porcelain), ZRIF 1.0 (0.5 mm infiltrated zirconia covered with 0.5 mm of porcelain), ZRF 1.5 (0.5 mm infiltrated zirconia covered with 1.0 mm of porcelain) ZRIF 1,5-infiltrated Zirconia (0.5 mm infiltrated zirconia covered with 1.0 mm of porcelain). After the biaxial bending test in an aqueous medium were determined Weibull modulus (m) and the characteristic strength (σθ). The fragments were analyzed by EDS, SEM, XRD and FTIR. The hardness (H) and fracture toughness were analyzed by nanoindentation, since the elastic modulus (E) by two techniques, nanoindentation and on impulse, and to evaluate the adhesion between the zirconia and porcelain was applied Scratch Test. 7 experimental conditions were modeled and analyzed by the finite element method. The infiltrated zirconia showed a monolithic structure with rounded grain wrapped in a silica matrix, and the presence of cubic and tetragonal zirconia. The XRD showed the formation of ZrSiO4 infiltrates in groups. The monolithic modules Weibull groups showed superior to ... / Mestre
50

Efeitos de lasers de alta potência na superfície de cerâmicas vítreas de dissilicato de lítio e sua resistência de união à dentina humana /

Feitosa, Fernanda Alves. January 2016 (has links)
Orientador: César Rogério Pucci / Banca: Rebeca Di Nicoló / Banca: Patrícia Moreira de Freitas / Banca: Taís Scaramucci Forlin / Banca: Symone Cristina Teixeira / Resumo:O objetivo desse estudo foi avaliar a eficiência da irradiação com lasers de alta potência e a influência da aplicação do silano previa ou posteriormente à irradiação com os lasers na resistência de união entre cerâmica vítrea de dissilicato de lítio, cimento resinoso e dentina humana. Foram confeccionados 50 espécimes troncocônicos de cerâmica (n=10), divididos aleatoriamente em 5 grupos: 1- ControleCondicionamento com ácido hidrofluorídrico 10% por 1 min e aplicação do silano; 2- Er:YAG - irradiação com laser Er:YAG (200 mJ e 10 Hz), seguido do condicionamento com ácido hidrofluorídrico 10% por 1 min e aplicação do silano; 3- Silano + Er:YAG - Condicionamento com ácido hidrofluorídrico 10% por 1 min, aplicação do silano e irradiação com laser Er:YAG nos mesmo parâmetros do grupo anterior; 4- Nd:YAG - irradiação com laser Nd:YAG (120 mJ e 10 Hz), seguido de condicionamento com ácido hidrofluorídrico 10% por 1 min e aplicação do silano, 5- Silano + Nd:YAG - Condicionamento com ácido hidrofluorídrico 10% por 1 min, aplicação do silano e irradiação com laser Nd:YAG nos mesmo parâmetros do grupo anterior. Após os tratamentos os espécimes cerâmicos foram cimentados com cimento resinoso de presa dual à superfície de dentina de 50 molares humanos incluídos em resina acrílica ativada quimicamente. Após armazenamento por 24 h foi realizado o ensaio de tração em máquina de ensaios universais com célula de carga de 10 KgF e velocidade constante de 1mm/min. Os dados obtidos foram submetidos à ANOVA 2-fatores e teste de Dunnet (α=5%). A análise dos padrões de fratura foram analisadas em estereomicroscopio. Adicionalmente foram confeccionados 15 espécimes em cerâmica no formato cilíndrico, submetidos aos mesmo tratamentos dos grupos anteriores (n=3) e utilizados para análise do ângulo de contato e análise em microscópio eletrônico de varredura. O teste de Dunnet mostrou diferenças... / Abstract:The aim of this study was to evaluate the efficiency of irradiation with high-power lasers and the influence of silane application before or after irradiation with lasers on the bond strength between lithium disilicate glass-ceramic, resin cement and human dentin. Fifty truncated-cones ceramic specimens (n=10) were randomly divided into 5 groups: Control- etching with hydrofluoric acid 10% for 1 min and application of silane; 2- Er - Er:YAG laser irradiation (200 mJ and 10 Hz), followed by etching with hydrofluoric acid 10% for 1 min and application of silane; 3- Sil + Er - etching with hydrofluoric acid 10% for 1 min, silane application and irradiation with Er: YAG laser in the same parameters as the previous group; 4- Nd:YAG laser - irradiation with Nd: YAG laser (120 mJ and 10 Hz), followed by etching with hydrofluoric acid 10% for 1 min and application of the silane, 5- Sil + Nd- Etching with hydrofluoric acid 10% for 1 min, silane application and irradiation with Nd: YAG laser on the same parameters as the previous group. After treatment, the ceramic specimens were cemented with dual cure resin cement to the dentin of 50 human molars included in acrylic resin. After storage for 24 h it was submitted to tensile test in a universal testing machine with 10 kgf load cell and constant speed of 1 mm/min. Data were submitted to ANOVA 2-way and Dunnet test (α = 5%). The analysis of fracture patterns were analyzed in stereomicroscope. In addition were made 15 ceramic specimens in cylindrical shape, subjected to the same treatment of the above groups (n = 3) and used for analysis of the contact angle analysis and scanning electron microscope. The Dunnet test showed significant differences between Control group (9.42 ± 2.27 MPa) and Er group (19.25 ± 3.7 MPa) and Sil + Er (14.11 ± 4.11 MPa). ANOVA 2-way (p <5%) for Laser Type (p <0.0001) and Technical of Silanization (p = 0.0002) showed significant differences for both factors, but not for their.. / Doutor

Page generated in 0.0426 seconds