• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 11
  • 11
  • 11
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

On some methods for the analysis of continuous dynamical systems / 連続力学系の解析法について

Suda, Tomoharu 23 March 2020 (has links)
京都大学 / 0048 / 新制・課程博士 / 博士(人間・環境学) / 甲第22521号 / 人博第924号 / 新制||人||221(附属図書館) / 2019||人博||924(吉田南総合図書館) / 京都大学大学院人間・環境学研究科共生人間学専攻 / (主査)准教授 木坂 正史, 教授 角 大輝, 教授 足立 匡義 / 学位規則第4条第1項該当 / Doctor of Human and Environmental Studies / Kyoto University / DFAM
2

Directional analysis of cardiac left ventricular motion from PET images. / Análise direcional do movimento do ventrículo esquerdo cardíaco a partir de imagens de PET.

Sims, John Andrew 28 June 2017 (has links)
Quantification of cardiac left ventricular (LV) motion from medical images provides a non-invasive method for diagnosing cardiovascular disease (CVD). The proposed study continues our group\'s line of research in quantification of LV motion by applying optical flow (OF) techniques to quantify LV motion in gated Rubidium Chloride-82Rb (82Rb) and Fluorodeoxyglucose-18F (FDG) PET image sequences. The following challenges arise from this work: (i) the motion vector field (MVF) should be made as accurate as possible to maximise sensitivity and specificity; (ii) the MVF is large and composed of 3D vectors in 3D space, making visual extraction of information for medical diagnosis dffcult by human observers. Approaches to improve the accuracy of motion quantification were developed. While the volume of interest is the region of the MVF corresponding to the LV myocardium, non-zero values of motion exist outside this volume due to artefacts in the motion detection method or from neighbouring structures, such as the right ventricle. Improvements in accuracy can be obtained by segmenting the LV and setting the MVF to zero outside the LV. The LV myocardium was automatically segmented in short-axis slices using the Hough circle transform to provide an initialisation to the distance regularised level set evolution algorithm. Our segmentation method attained Dice similarity measure of 93.43% when tested over 395 FDG slices, compared with manual segmentation. Strategies for improving OF performance at motion boundaries were investigated using spatially varying averaging filters, applied to synthetic image sequences. Results showed improvements in motion quantification accuracy using these methods. Kinetic Energy Index (KEf), an indicator of cardiac motility, was used to assess 63 individuals with normal and altered/low cardiac function from a 82Rb PET image database. Sensitivity and specificity tests were performed to evaluate the potential of KEf as a classifier of cardiac function, using LV ejection fraction as gold standard. A receiver operating characteristics curve was constructed, which provided an area under the curve of 0.906. Analysis of LV motion can be simplified by visualisation of directional motion field components, namely radial, rotational (or circumferential) and linear, obtained through automated decomposition. The Discrete Helmholtz Hodge Decomposition (DHHD) was used to generate these components in an automated manner, with a validation performed using synthetic cardiac motion fields from the Extended Cardiac Torso phantom. Finally, the DHHD was applied to OF fields from gated FDG images, allowing an analysis of directional components from an individual with normal cardiac function and a patient with low function and a pacemaker fitted. Motion field quantification from PET images allows the development of new indicators to diagnose CVDs. The ability of these motility indicators depends on the accuracy of the quantification of movement, which in turn can be determined by characteristics of the input images, such as noise. Motion analysis provides a promising and unprecedented approach to the diagnosis of CVDs. / A quantificação do movimento cardíaco do ventrículo esquerdo (VE) a partir de imagens médicas fornece um método não invasivo para o diagnóstico de doenças cardiovasculares (DCV). O estudo aqui proposto continua na mesma linha de pesquisa do nosso grupo sobre quantificação do movimento do VE por meio de técnicas de fluxo óptico (FO), aplicando estes métodos para quantificar o movimento do VE em sequências de imagens associadas às substâncias de cloreto de rubídio-82Rb (82Rb) e fluorodeoxiglucose-18F (FDG) PET. Com a extração dos campos vetoriais surgiram os seguintes desafios: (i) o campo vetorial de movimento (motion vector field, MVF) deve ser feito da forma mais precisa possível para maximizar a sensibilidade e especificidade; (ii) o MVF é extenso e composto de vetores 3D no espaço 3D, dificultando a análise visual de informações por observadores humanos para o diagnóstico médico. Foram desenvolvidas abordagens para melhorar a precisão da quantificação de movimento, considerando que o volume de interesse seja a região do MVF correspondente ao miocárdio do VE, em que valores de movimento não nulos existem fora deste volume devido aos artefatos do método de detecção de movimento ou de estruturas vizinhas, como o ventrículo direito. As melhorias na precisão foram obtidas segmentando o VE e ajustando os valores de MVF para zero fora do VE. O miocárdio VE foi segmentado automaticamente em fatias de eixo curto usando a Transformada de Hough na detecção de círculos para fornecer uma inicialização ao algoritmo de curvas de nível, um tipo de modelo deformável. A segmentação automática do VE atingiu 93,43% de medida de similaridade Dice, quando foi testado em 395 fatias de eixo menor de FDG, comparado com a segmentação manual. Estratégias para melhorar o desempenho do algoritmo OF nas bordas de movimento foram investigadas usando spatially varying averaging filters, aplicados em seqüências de imagens sintéticas. Os resultados mostraram melhorias na precisão de quantificação de movimento utilizando estes métodos. O Índice de Energia Cinética (KEf), um indicador de motilidade cardíaca, foi utilizado para avaliar 63 sujeitos com função cardíaca normal e alterada / baixa de uma base de dados de imagens PET de 82Rb. Foram realizados testes de sensibilidade e especificidade para avaliar o potencial de KEf para classificar a função cardíaca, utilizando a fração de ejeção do VE como padrão ouro. Foi construída uma curva ROC, que proporcionou uma área sob a curva de 0,906. A análise do movimento do VE pode ser simplificada pela visualização de componentes de campo de movimento direcional, ou seja, radial, rotacional (ou circunferencial) e linear, obtidos por decomposição automatizada. A decomposição discreta de Helmholtz Hodge (DHHD) foi utilizada para gerar estes componentes de forma automatizada, com uma validação utilizando campos de movimento cardíaco sintéticos a partir do conjunto Extended Cardiac Torso Phantom. Finalmente, o método DHHD foi aplicado a campos de FO, criado a partir de imagens FDG, permitindo uma análise de componentes direcionais de um indivíduo com função cardíaca normal e um paciente com baixa função e utilizando um marca-passo. A quantificação do campo de movimento a partir de imagens PET possibilita o desenvolvimento de novos indicadores para diagnosticar DCVs. A capacidade destes indicadores de motilidade depende na precisão da quantificação de movimento que, por sua vez, pode ser determinado por características das imagens de entrada como ruído. A análise de movimento fornece um promissor e sem precedente método para o diagnóstico de DCVs.
3

Directional analysis of cardiac left ventricular motion from PET images. / Análise direcional do movimento do ventrículo esquerdo cardíaco a partir de imagens de PET.

John Andrew Sims 28 June 2017 (has links)
Quantification of cardiac left ventricular (LV) motion from medical images provides a non-invasive method for diagnosing cardiovascular disease (CVD). The proposed study continues our group\'s line of research in quantification of LV motion by applying optical flow (OF) techniques to quantify LV motion in gated Rubidium Chloride-82Rb (82Rb) and Fluorodeoxyglucose-18F (FDG) PET image sequences. The following challenges arise from this work: (i) the motion vector field (MVF) should be made as accurate as possible to maximise sensitivity and specificity; (ii) the MVF is large and composed of 3D vectors in 3D space, making visual extraction of information for medical diagnosis dffcult by human observers. Approaches to improve the accuracy of motion quantification were developed. While the volume of interest is the region of the MVF corresponding to the LV myocardium, non-zero values of motion exist outside this volume due to artefacts in the motion detection method or from neighbouring structures, such as the right ventricle. Improvements in accuracy can be obtained by segmenting the LV and setting the MVF to zero outside the LV. The LV myocardium was automatically segmented in short-axis slices using the Hough circle transform to provide an initialisation to the distance regularised level set evolution algorithm. Our segmentation method attained Dice similarity measure of 93.43% when tested over 395 FDG slices, compared with manual segmentation. Strategies for improving OF performance at motion boundaries were investigated using spatially varying averaging filters, applied to synthetic image sequences. Results showed improvements in motion quantification accuracy using these methods. Kinetic Energy Index (KEf), an indicator of cardiac motility, was used to assess 63 individuals with normal and altered/low cardiac function from a 82Rb PET image database. Sensitivity and specificity tests were performed to evaluate the potential of KEf as a classifier of cardiac function, using LV ejection fraction as gold standard. A receiver operating characteristics curve was constructed, which provided an area under the curve of 0.906. Analysis of LV motion can be simplified by visualisation of directional motion field components, namely radial, rotational (or circumferential) and linear, obtained through automated decomposition. The Discrete Helmholtz Hodge Decomposition (DHHD) was used to generate these components in an automated manner, with a validation performed using synthetic cardiac motion fields from the Extended Cardiac Torso phantom. Finally, the DHHD was applied to OF fields from gated FDG images, allowing an analysis of directional components from an individual with normal cardiac function and a patient with low function and a pacemaker fitted. Motion field quantification from PET images allows the development of new indicators to diagnose CVDs. The ability of these motility indicators depends on the accuracy of the quantification of movement, which in turn can be determined by characteristics of the input images, such as noise. Motion analysis provides a promising and unprecedented approach to the diagnosis of CVDs. / A quantificação do movimento cardíaco do ventrículo esquerdo (VE) a partir de imagens médicas fornece um método não invasivo para o diagnóstico de doenças cardiovasculares (DCV). O estudo aqui proposto continua na mesma linha de pesquisa do nosso grupo sobre quantificação do movimento do VE por meio de técnicas de fluxo óptico (FO), aplicando estes métodos para quantificar o movimento do VE em sequências de imagens associadas às substâncias de cloreto de rubídio-82Rb (82Rb) e fluorodeoxiglucose-18F (FDG) PET. Com a extração dos campos vetoriais surgiram os seguintes desafios: (i) o campo vetorial de movimento (motion vector field, MVF) deve ser feito da forma mais precisa possível para maximizar a sensibilidade e especificidade; (ii) o MVF é extenso e composto de vetores 3D no espaço 3D, dificultando a análise visual de informações por observadores humanos para o diagnóstico médico. Foram desenvolvidas abordagens para melhorar a precisão da quantificação de movimento, considerando que o volume de interesse seja a região do MVF correspondente ao miocárdio do VE, em que valores de movimento não nulos existem fora deste volume devido aos artefatos do método de detecção de movimento ou de estruturas vizinhas, como o ventrículo direito. As melhorias na precisão foram obtidas segmentando o VE e ajustando os valores de MVF para zero fora do VE. O miocárdio VE foi segmentado automaticamente em fatias de eixo curto usando a Transformada de Hough na detecção de círculos para fornecer uma inicialização ao algoritmo de curvas de nível, um tipo de modelo deformável. A segmentação automática do VE atingiu 93,43% de medida de similaridade Dice, quando foi testado em 395 fatias de eixo menor de FDG, comparado com a segmentação manual. Estratégias para melhorar o desempenho do algoritmo OF nas bordas de movimento foram investigadas usando spatially varying averaging filters, aplicados em seqüências de imagens sintéticas. Os resultados mostraram melhorias na precisão de quantificação de movimento utilizando estes métodos. O Índice de Energia Cinética (KEf), um indicador de motilidade cardíaca, foi utilizado para avaliar 63 sujeitos com função cardíaca normal e alterada / baixa de uma base de dados de imagens PET de 82Rb. Foram realizados testes de sensibilidade e especificidade para avaliar o potencial de KEf para classificar a função cardíaca, utilizando a fração de ejeção do VE como padrão ouro. Foi construída uma curva ROC, que proporcionou uma área sob a curva de 0,906. A análise do movimento do VE pode ser simplificada pela visualização de componentes de campo de movimento direcional, ou seja, radial, rotacional (ou circunferencial) e linear, obtidos por decomposição automatizada. A decomposição discreta de Helmholtz Hodge (DHHD) foi utilizada para gerar estes componentes de forma automatizada, com uma validação utilizando campos de movimento cardíaco sintéticos a partir do conjunto Extended Cardiac Torso Phantom. Finalmente, o método DHHD foi aplicado a campos de FO, criado a partir de imagens FDG, permitindo uma análise de componentes direcionais de um indivíduo com função cardíaca normal e um paciente com baixa função e utilizando um marca-passo. A quantificação do campo de movimento a partir de imagens PET possibilita o desenvolvimento de novos indicadores para diagnosticar DCVs. A capacidade destes indicadores de motilidade depende na precisão da quantificação de movimento que, por sua vez, pode ser determinado por características das imagens de entrada como ruído. A análise de movimento fornece um promissor e sem precedente método para o diagnóstico de DCVs.
4

Applications of the Helmholtz-Hodge Decomposition to Networks and Random Processes

Strang, Alexander 07 September 2020 (has links)
No description available.
5

[en] UNCERTAINTY ANALYSIS OF 2D VECTOR FIELDS THROUGH THE HELMHOLTZ-HODGE DECOMPOSITION / [pt] ANALISE DE INCERTEZAS EM CAMPOS VETORIAIS 2D COM O USO DA DECOMPOSIÇÃO DE HELMHOLTZ-HODGE

PAULA CECCON RIBEIRO 20 March 2017 (has links)
[pt] Campos vetoriais representam um papel principal em diversas aplicações científicas. Eles são comumente gerados via simulações computacionais. Essas simulações podem ser um processo custoso, dado que em muitas vezes elas requerem alto tempo computacional. Quando pesquisadores desejam quantificar a incerteza relacionada a esse tipo de aplicação, costuma-se gerar um conjunto de realizações de campos vetoriais, o que torna o processo ainda mais custoso. A Decomposição de Helmholtz-Hodge é uma ferramenta útil para a interpretação de campos vetoriais uma vez que ela distingue componentes conservativos (livre de rotação) de componentes que preservam massa (livre de divergente). No presente trabalho, vamos explorar a aplicabilidade de tal técnica na análise de incerteza de campos vetoriais 2D. Primeiramente, apresentaremos uma abordagem utilizando a Decomposição de Helmholtz-Hodge como uma ferramenta básica na análise de conjuntos de campos vetoriais. Dado um conjunto de campos vetoriais epsilon, obtemos os conjuntos formados pelos componentes livre de rotação, livre de divergente e harmônico, aplicando a Decomposição Natural de Helmholtz- Hodge em cada campo vetorial em epsilon. Com esses conjuntos em mãos, nossa proposta não somente quantifica, por meio de análise estatística, como cada componente é pontualmente correlacionado ao conjunto de campos vetoriais original, como também permite a investigação independente da incerteza relacionado aos campos livre de rotação, livre de divergente e harmônico. Em sequência, propomos duas técnicas que em conjunto com a Decomposição de Helmholtz-Hodge geram, de forma estocástica, campos vetoriais a partir de uma única realização. Por fim, propomos também um método para sintetizar campos vetoriais a partir de um conjunto, utilizando técnicas de Redução de Dimensionalidade e Projeção Inversa. Testamos os métodos propostos tanto em campos sintéticos quanto em campos numericamente simulados. / [en] Vector field plays an essential role in a large range of scientific applications. They are commonly generated through computer simulations. Such simulations may be a costly process because they usually require high computational time. When researchers want to quantify the uncertainty in such kind of applications, usually an ensemble of vector fields realizations are generated, making the process much more expensive. The Helmholtz-Hodge Decomposition is a very useful instrument for vector field interpretation because it traditionally distinguishes conservative (rotational-free) components from mass-preserving (divergence-free) components. In this work, we are going to explore the applicability of such technique on the uncertainty analysis of 2-dimensional vector fields. First, we will present an approach of the use of the Helmholtz-Hodge Decomposition as a basic tool for the analysis of a vector field ensemble. Given a vector field ensemble epsilon, we firstly obtain the corresponding rotational-free, divergence-free and harmonic component ensembles by applying the Natural Helmholtz-Hodge Decomposition to each1 vector field in epsilon. With these ensembles in hand, our proposal not only quantifies, via a statistical analysis, how much each component ensemble is point-wisely correlated to the original vector field ensemble, but it also allows to investigate the uncertainty of rotational-free, divergence-free and harmonic components separately. Then, we propose two techniques that jointly with the Helmholtz-Hodge Decomposition stochastically generate vector fields from a single realization. Finally, we propose a method to synthesize vector fields from an ensemble, using both the Dimension Reduction and Inverse Projection techniques. We test the proposed methods with synthetic vector fields as well as with simulated vector fields.
6

[en] POISSON EQUATION AND THE HELMHOLTZ-HODGE DECOMPOSITION WITH SPH OPERATORS / [pt] A EQUAÇÃO DE POISSON E A DECOMPOSIÇÃO DE HELMHOLTZ-HODGE COM OPERADORES SPH

FABIANO PETRONETTO DO CARMO 29 August 2008 (has links)
[pt] A equação diferencial parcial de Poisson é de fundamental importância em várias áreas de pesquisa, dentre elas: matemática, física e engenharia. Para resolvê-la numericamente utilizam-se vários métodos, tais como os já tradicionais métodos das diferenças finitas e dos elementos finitos. Este trabalho propõe um método para resolver a equação de Poisson, utilizando uma abordagem de sistema de partículas conhecido como SPH, do inglês Smoothed Particles Hydrodynamics. O método proposto para a solução da equação de Poisson e os operadores diferenciais discretos definidos no método SPH, chamados de operadores SPH, são utilizados neste trabalho em duas aplicações: na decomposição de campos vetoriais; e na simulação numérica de escoamentos de fluidos monofásicos e bifásicos utilizando a equação de Navier-Stokes. / [en] Poisson`s equation is of fundamental importance in many research areas in engineering and the mathematical and physical sciences. Its numerical solution uses several approaches among them finite differences and finite elements. In this work we propose a method to solve Poisson`s equation using the particle method known as SPH (Smoothed Particle Hydrodynamics). The proposed method together with an accurate analysis of the discrete differential operators defined by SPH are applied in two related situations: the Hodge-Helmholtz vector field decomposition and the numerical simulation of the Navier-Stokes equations.
7

Untersuchung optischer Verfahren zur gleichzeitigen Messung von Strömungs- und Schallfeldern an aeroakustischen Schalldämpfern / Investigation of optical techniques for the simultaneous measurement of flow and sound fields at aeroacoustic sound absorbers

Haufe, Daniel 11 April 2016 (has links) (PDF)
Um Flugzeugtriebwerke und stationäre Gasturbinen schadstoffärmer und leiser zu gestalten, werden effizientere Dämpfer zur Unterdrückung des in der Brennkammer entstehenden Schalls benötigt. Hierfür sollen durchströmte, perforierte Wandauskleidungen eingesetzt werden, die sogenannten Bias-Flow-Liner (BFL). Die Erhöhung der Dämpfungseffizienz von BFL erfordert jedoch ein tiefer gehendes Verständnis der aeroakustischen Dämpfungsmechanismen. Die Analyse der Mechanismen bedarf einer experimentellen Untersuchung des Vektorfeldes der Fluidgeschwindigkeit, die sowohl die Strömungsgeschwindigkeit als auch die Schallschnelle enthält. Zur gleichzeitigen Erfassung beider Größen wird eine berührungslose sowie örtlich und zeitlich hoch aufgelöste Messung der Geschwindigkeit von im Mittel 10 m/s bis 100 m/s bei einer Unsicherheit von maximal 10 mm/s für die Schallschnelleamplitude und einem Dynamikumfang von 1000 bis 10 000 benötigt. Für diese Messung sind optische Verfahren vielversprechend, genügten aber bisher nicht diesen Anforderungen. Deshalb wurden im ersten Schritt neuartige optische Geschwindigkeitsmessverfahren erstmals bezüglich der Eignung für aeroakustische Untersuchungen am BFL, speziell hinsichtlich der Unsicherheit und des Dynamikumfangs, charakterisiert: der Laser-Doppler-Geschwindigkeitsprofilsensor (LDV-PS), die akustische Particle Image Velocimetry (A-PIV) und die Doppler-Global-Velozimetrie mit Frequenzmodulation (FM-DGV). Aus dem Messunsicherheitsbudget geht für alle Verfahren die turbulente Strömungsfluktuation als dominierender Beitrag zur Unsicherheit für die gemessene Schnelleamplitude hervor, wobei die Unsicherheit durch eine Erhöhung der Messdauer gesenkt werden kann. Für eine Messdauer von 80 s beträgt die mittels FM-DGV erzielte Unsicherheit bei einer mittleren Strömungsgeschwindigkeit von 100 m/s beispielsweise 10 mm/s, woraus ein Dynamikumfang von 10 000 resultiert. Demnach erfüllen die neuartigen Verfahren die Voraussetzungen für die Anwendung am BFL, was im zweiten Schritt experimentell demonstriert wurde. Hierbei wurde zwecks Untersuchung kleiner Strukturen der LDV-PS mit einer feinen Ortsauflösung von minimal 10 µm genutzt. Ferner wurde die großflächige Erfassung mittels A-PIV zur Untersuchung der Wechselwirkung zwischen den Perforationslöchern eingesetzt und eine spektrale Untersuchung der mittels FM-DGV gemessenen Geschwindigkeit bei einer hohen Messrate von 100 kHz durchgeführt. Im Ergebnis wurden folgende Erkenntnisse zum Dämpfungsverhalten gewonnen: Am BFL tritt eine Interaktion von Strömung und Schall auf, die zu einer Oszillation der Geschwindigkeit mit hoher Amplitude bei der Schallanregungsfrequenz führt. Aus der erstmals durchgeführten Zerlegung der volumetrisch gemessenen Geschwindigkeit in Strömungsgeschwindigkeit und Schallschnelle resultiert, dass die akustisch induzierte oszillierende Geschwindigkeit vorwiegend dem Strömungsfeld zuzuordnen ist. Folglich wurde ein Energietransfer vom Schallfeld ins Strömungsfeld am BFL nachgewiesen, der wegen des sich typischerweise anschließenden Zerfalls von Strömungswirbeln und der finalen Umwandlung in Wärmeenergie zur Dämpfung beiträgt. Zudem wurde mittels spektraler Analyse der Geschwindigkeit ein breitbandiger Energiezuwachs bei tonaler Schallanregung festgestellt, welcher mit der Dämpfungseffizienz korreliert ist. Somit wird die These der primär von der akustisch induzierten Wirbelbildung herrührenden Dämpfung gestützt. Diese mit den neuartigen optischen Messverfahren gewonnenen Erkenntnisse tragen perspektivisch zur Optimierung von BFL hinsichtlich einer hohen Dämpfungseffizienz bei.
8

Décomposition de Hodge-Helmholtz discrète / Discrete Helmholtz-Hodge Decomposition

Lemoine, Antoine 27 November 2014 (has links)
Nous proposons dans ce mémoire de thèse une méthodologie permettant la résolution du problème de la décomposition de Hodge-Helmholtz discrète sur maillages polyédriques. Le défi de ce travail consiste à respecter les propriétés de la décomposition au niveau discret. Pour répondre à cet objectif, nous menons une étude bibliographique nous permettant d'identifier la nécessité de la mise en oeuvre de schémas numériques mimétiques. La description ainsi que la validation de la mise en oeuvre de ces schémas sont présentées dans ce mémoire. Nous revisitons et améliorons les méthodes de décomposition que nous étudions ensuite au travers d'expériences numériques. En particulier, nous détaillons le choix d'un solveur linéaire ainsi que la convergence des quantités extraites sur un ensemble varié de maillages polyédriques et de conditions aux limites. Nous appliquons finalement la décomposition de Hodge-Helmholtz à l'étude de deux écoulements turbulents : un écoulement en canal plan et un écoulement turbulent homogène isotrope. / We propose in this thesis a methodology to compute the Helmholtz-Hodge decomposition on discrete polyhedral meshes. The challenge of this work isto preserve the properties of the decomposition at the discrete level. In our literature survey, we have identified the need of mimetic schemes to achieve our goal. The description and validation of our implementation of these schemes are presented inthis document. We revisit and improve the methods of decomposition we then study through numerical experiments. In particular, we detail our choice of linear solvers and the convergence of extracted quantities on various series of polyhedral meshes and boundary conditions. Finally, we apply the Helmholtz-Hodge decomposition to the study of two turbulent flows: a turbulent channel flow and a homogeneous isotropic turbulent flow.
9

Untersuchung optischer Verfahren zur gleichzeitigen Messung von Strömungs- und Schallfeldern an aeroakustischen Schalldämpfern

Haufe, Daniel 18 December 2015 (has links)
Um Flugzeugtriebwerke und stationäre Gasturbinen schadstoffärmer und leiser zu gestalten, werden effizientere Dämpfer zur Unterdrückung des in der Brennkammer entstehenden Schalls benötigt. Hierfür sollen durchströmte, perforierte Wandauskleidungen eingesetzt werden, die sogenannten Bias-Flow-Liner (BFL). Die Erhöhung der Dämpfungseffizienz von BFL erfordert jedoch ein tiefer gehendes Verständnis der aeroakustischen Dämpfungsmechanismen. Die Analyse der Mechanismen bedarf einer experimentellen Untersuchung des Vektorfeldes der Fluidgeschwindigkeit, die sowohl die Strömungsgeschwindigkeit als auch die Schallschnelle enthält. Zur gleichzeitigen Erfassung beider Größen wird eine berührungslose sowie örtlich und zeitlich hoch aufgelöste Messung der Geschwindigkeit von im Mittel 10 m/s bis 100 m/s bei einer Unsicherheit von maximal 10 mm/s für die Schallschnelleamplitude und einem Dynamikumfang von 1000 bis 10 000 benötigt. Für diese Messung sind optische Verfahren vielversprechend, genügten aber bisher nicht diesen Anforderungen. Deshalb wurden im ersten Schritt neuartige optische Geschwindigkeitsmessverfahren erstmals bezüglich der Eignung für aeroakustische Untersuchungen am BFL, speziell hinsichtlich der Unsicherheit und des Dynamikumfangs, charakterisiert: der Laser-Doppler-Geschwindigkeitsprofilsensor (LDV-PS), die akustische Particle Image Velocimetry (A-PIV) und die Doppler-Global-Velozimetrie mit Frequenzmodulation (FM-DGV). Aus dem Messunsicherheitsbudget geht für alle Verfahren die turbulente Strömungsfluktuation als dominierender Beitrag zur Unsicherheit für die gemessene Schnelleamplitude hervor, wobei die Unsicherheit durch eine Erhöhung der Messdauer gesenkt werden kann. Für eine Messdauer von 80 s beträgt die mittels FM-DGV erzielte Unsicherheit bei einer mittleren Strömungsgeschwindigkeit von 100 m/s beispielsweise 10 mm/s, woraus ein Dynamikumfang von 10 000 resultiert. Demnach erfüllen die neuartigen Verfahren die Voraussetzungen für die Anwendung am BFL, was im zweiten Schritt experimentell demonstriert wurde. Hierbei wurde zwecks Untersuchung kleiner Strukturen der LDV-PS mit einer feinen Ortsauflösung von minimal 10 µm genutzt. Ferner wurde die großflächige Erfassung mittels A-PIV zur Untersuchung der Wechselwirkung zwischen den Perforationslöchern eingesetzt und eine spektrale Untersuchung der mittels FM-DGV gemessenen Geschwindigkeit bei einer hohen Messrate von 100 kHz durchgeführt. Im Ergebnis wurden folgende Erkenntnisse zum Dämpfungsverhalten gewonnen: Am BFL tritt eine Interaktion von Strömung und Schall auf, die zu einer Oszillation der Geschwindigkeit mit hoher Amplitude bei der Schallanregungsfrequenz führt. Aus der erstmals durchgeführten Zerlegung der volumetrisch gemessenen Geschwindigkeit in Strömungsgeschwindigkeit und Schallschnelle resultiert, dass die akustisch induzierte oszillierende Geschwindigkeit vorwiegend dem Strömungsfeld zuzuordnen ist. Folglich wurde ein Energietransfer vom Schallfeld ins Strömungsfeld am BFL nachgewiesen, der wegen des sich typischerweise anschließenden Zerfalls von Strömungswirbeln und der finalen Umwandlung in Wärmeenergie zur Dämpfung beiträgt. Zudem wurde mittels spektraler Analyse der Geschwindigkeit ein breitbandiger Energiezuwachs bei tonaler Schallanregung festgestellt, welcher mit der Dämpfungseffizienz korreliert ist. Somit wird die These der primär von der akustisch induzierten Wirbelbildung herrührenden Dämpfung gestützt. Diese mit den neuartigen optischen Messverfahren gewonnenen Erkenntnisse tragen perspektivisch zur Optimierung von BFL hinsichtlich einer hohen Dämpfungseffizienz bei.
10

Contributions à la théorie des jeux : valeur asymptotique des jeux dépendant de la fréquence et décompositions des jeux finis / Contributions in game theory : asymptotic value in frequency dependant games and decompositions of finite games

Pnevmatikos, Nikolaos 01 July 2016 (has links)
Les problèmes abordés et les résultats obtenus dans cette thèse se divisent en deux parties. La première concerne l'étude de la valeur asymptotique de jeux dépendant de la fréquence (jeux-FD). Nous introduisons un jeu différentiel associé au jeu-FD dont la valeur se ramène à une équation de Hamilton-Jacobi-Bellman-lsaacs. En affrontant un problème d'irrégularité à l'origine, nous prouvons l’existence de la valeur du jeu différentiel sur [0.1 ] et ceci nous permet de prouver que la valeur du jeu FD converge vers la valeur du jeu continu qui débute à l'état initial 0. Dans la deuxième partie, l'objectif fondamental est la décomposition de l'espace des jeux finis en sous espaces des jeux adéquats et plus faciles à étudier vu que leurs équilibres sont distingués. Cette partie est divisée en deux chapitres. Dans le premier chapitre, nous établissons une décomposition canonique de tout jeu arbitraire fini en trois composantes et nous caractérisons les équilibres approximatifs d'un jeu donné par les équilibres uniformément mixtes et en stratégies dominantes lesquels apparaissent sur ses composantes. Dans le deuxième chapitre, nous introduisons sur l'espace des jeux finis une famille de produits scalaires et nous définissons la classe des jeux harmoniques relativement au produit scalaire choisi dans cette famille. Inspiré par la décomposition de Helmholtz-Hodge appliquée aux jeux par Candogan et al. (2011), nous établissons une décomposition orthogonale de l'espace des jeux finis, par rapport au produit scalaire choisi, en les sous espaces des jeux potentiels, des jeux harmoniques et des jeux non­stratégiques c nous généralisons les résultats de Candogan et al. (2011). / The problems addressed and results obtained in this thesis are divided in two parts. The first part concerns the study of the asymptotic value of frequency-dependent games (FD-games). We introduce a differential game associated to the FD-game whose value leads to a Hamilton-Jacob-Bellman-lsaacs equation. Although an irregularity occurs at the origin, we prove existence of the value in the differential game played over [0.1 ], which allows to prove that the value of the FD-game, as the number of stages tend to infinity, converges to the value of the continuous-time game with initial state 0. ln the second part, the objective is the decomposition of the space of finite games in subspaces of suitable games which admit disguised equilibria and more tractable analysis. This part is divided in two chapters. In the first chapter, we establish a canonical decomposition of an arbitrary game into three components and we characterize the approximate equilibria of a given game in terms of the uniform equilibrium and the equilibrium in dominant strategies that appear in its components. In the second part, we introduce a family of inner products in the space of finite games and we define the class of harmonic games relatively to the chosen inner product. Inspired of the Helmholtz-Hodge decomposition applied to games by Candogan et al (2011 ), we establish an orthogonal decomposition of the space of finite games with respect to the chosen inner product, in the subspaces of potential harmonic and non-strategic games and we further generalize several results of Candogan et al (2011).

Page generated in 0.0566 seconds